Analyze Waveform or Trace Data
Taking Automatic Measurements in the Time Domain
To take an automatic measurement in the time domain:
1.
Push
Measure
.
2.
Push
Domain
to select
Time
domain
measurements.
Domain
Time
Frequency
Add Mea-
surement
Remove
Measure-
ment
Indicators
Waveform
His-
tograms
More
Bring
Cursors on
Screen
3.
Push
Add Measurement
.
4.
Turn multipurpose knob
b
to select the
speci
fi
c measurement. If needed, then turn
multipurpose knob
a
to select the channel to
measure on.
5.
To remove a measurement, push
Remove
Measurement
, turn multipurpose knob
a
to select the speci
fi
c measurement, and
push
OK Remove Measurement
on the
side-bezel menu.
Quick Tips
To remove all measurements, select
Remove All Measurements
.
A
symbol appears instead of the expected numerical measurement if a vertical clipping condition exists. Part of the
waveform is above or below the display. To obtain a proper numerical measurement, turn the vertical scale and position
knobs to make all of the waveform appear in the display.
If the oscilloscope displays a
Low Resolution
message, increase the record length of the acquisition so that the
oscilloscope has more points from which to calculate the measurement.
MDO4000 Series Oscilloscopes User Manual
121
Содержание MDO4054-3
Страница 2: ...x MDO4000 Series Mixed Domain Oscilloscopes ZZZ User Manual P071291300 071 2913 00...
Страница 3: ......
Страница 4: ...MDO4000 Series Mixed Domain Oscilloscopes ZZZ User Manual xx www tektronix com 071 2913 00...
Страница 11: ...Table of Contents iv MDO4000 Series Oscilloscopes User Manual...
Страница 19: ...Preface xii MDO4000 Series Oscilloscopes User Manual...
Страница 215: ...Appendix C P6616 General Purpose Logic Probe Information 196 MDO4000 Series Oscilloscopes User Manual...