Series 2268 850 Watt DC Power Supplies Reference Manual
Analog Programming & Isolated Analog Programming
2268S-901-01 Rev. A / January 2015
79
Voltage-Controlled Current APG Setup
Activating APG Current Mode
To activate APG current mode using an external voltage source:
1.
Turn the 9-position mode control to the CAP position or press the rotary
Adjust/Enter control if the mode control is already at the CAP position.
is displayed on the output voltage display.
2.
Turn the rotary Adjust/Enter control to select source
(Voltage source from
non-isolated connector).
3.
Press the rotary Adjust/Enter control to commit the selected mode.
is
displayed on the output voltage display.
4.
Select the input source level using the rotary Adjust/Enter control.
5.
Once the desired level has been selected, press the rotary Adjust/ Enter control to
commit the change.
The display will return to the normal display.
Deactivating APG Current Mode
To deactivate the APG current mode:
1.
Turn the 9-position mode control to the CAP position or press the rotary
Adjust/Enter control if the mode control is already at the CAP position.
2.
ΧΑΠρ
is displayed on the output voltage display.
3.
Turn the rotary Adjust/Enter control to select
.
4.
Press the rotary Adjust/Enter control to commit the change.
The display will return to the normal display.