Command Groups
Command
Description
Sets or returns the pattern length of the
PatternSync portion of the trigger system
Sets the trigger level to 50% of the applied
signal
Sets or returns the trigger slope
Sets or returns the trigger source
Returns the trigger system status
Vertical Command Group
You use the commands in the Vertical Command Group to control the vertical
setup of all live (channel) waveforms for acquisition and to control the display of
channel, reference, and math waveforms. This group contains commands to set
up the vertical parameters for either electrical or optical signals, depending on
the sampling module in use.
You can use the commands in this group to do the following:
Enable or disable the display of any channel, math, or reference waveform.
Set which waveform is affected by the front-panel controls.
Set the vertical scale for each channel, math, or reference waveform.
Set the vertical position of a waveform. The vertical position affects only the
display position of a channel, math, or reference waveform.
Set the offset value to shift the vertical acquisition window to match the
waveform data that you want to acquire (affects only channels).
Set deskew and/or delay values to time align channels.
Set the units for channel waveforms. If you set this value to Auto, the
instrument automatically selects the units. If you set this value to any setting
other than Auto (Volt, Amp, or Watt), the instrument will apply these units to
the vertical axis.
Set the external attenuation factor (as a multiplier or as a dB value) on an
acquisition channel waveform to a value matching the amount of attenuation
applied externally, before the signal enters the sampling head or probe tip
input.
Set the wavelength to match the wavelength of the optical signal you are using.
Set the type of
fi
ltering, if any, you want performed on the selected optical
channel.
Specify bandwidth for use on the selected optical channel.
2-40
DSA8300 Programmer Manual
Содержание DSA8300
Страница 1: ...xx DSA8300 Digital Serial Analyzer ZZZ Programmer Manual P077057002 077 0570 02 ...
Страница 2: ......
Страница 3: ...DSA8300 Digital Serial Analyzer ZZZ Programmer Manual xx Revision B www tektronix com 077 0570 02 ...
Страница 8: ...Preface iv DSA8300 Programmer Manual ...
Страница 9: ...Getting Started ...
Страница 10: ......
Страница 15: ...Syntax and Commands ...
Страница 16: ......
Страница 404: ...Commands Listed in Alphabetical Order 2 388 DSA8300 Programmer Manual ...
Страница 405: ...Status and Events ...
Страница 406: ......
Страница 426: ...Status and Events 3 20 DSA8300 Programmer Manual ...
Страница 427: ...Examples ...
Страница 428: ......
Страница 431: ...Appendices ...
Страница 432: ......
Страница 433: ...Appendix A Character Set DSA8300 Programmer Manual A 1 ...
Страница 434: ...Appendix A Character Set A 2 DSA8300 Programmer Manual ...
Страница 446: ...Appendix C Factory Default Setup Values C 8 DSA8300 Programmer Manual ...