background image

Instructions

TDS6UP, TDS7UP, and CSA7UP Option CPU
Upgrade Kit

071-1244-00

*P071124400*

071124400

Warning

The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.

www.tektronix.com

Содержание CSA7UP

Страница 1: ...244 00 P071124400 071124400 Warning The servicing instructions are for use by qualified personnel only To avoid personal injury do not perform any servicing unless you are qualified to do so Refer to...

Страница 2: ...and foreign patents issued and pending Information in this publication supercedes that in all previously published material Specifications and price change privileges reserved Tektronix Inc P O Box 50...

Страница 3: ...ts of this product unless another person capable of rendering first aid and resuscitation is present Disconnect Power To avoid electric shock switch off the instrument power then disconnect the power...

Страница 4: ...Service Safety Summary 2 TDS6UP TDS7UP and CSA7UP Option CPU Upgrade Kit...

Страница 5: ...cedures in order Products TDS6000 Series All serial numbers TDS7000 Series All serial numbers CSA7000 Series All serial numbers Minimum Tool and Equipment List Table 1 Equipment list Required tools an...

Страница 6: ...umber Description 1 1 ea 650 4562 00 COMPONENT KIT MOTHERBOARD MICROPROCESSOR UPGRADE TDS6 7UP OPTION CPU 2 1 ea 407 4880 01 BRACKET CD ROM REAR DRIVE BAY CHASSIS 0 035 CRS 1 ea 020 2349 XX SOFTWARE K...

Страница 7: ...ce for installation assistance CAUTION To prevent static discharge damage service the product only in a static free environment Observe standard handling precautions for static sensi tive devices whil...

Страница 8: ...OTE Read Equipment list for a list of the tools needed to remove and install modules in this instrument See Table 1 on page 3 Equipment Required Most modules in the TDS6000 TDS7000 and CSA7000 Series...

Страница 9: ...s the On Standby switch 3 Power off the rear panel power switch before servicing the power cord 4 Orient the instrument Set the instrument so that the bottom is down on the work surface and the rear i...

Страница 10: ...screws that secure the acquisition trim to the instrument b Remove the acquisition trim from the instrument 4 Remove the top cover trim Use Figure 3 on page 9 as a guide a Remove the accessory pouch...

Страница 11: ...on trim Right side trim T 15 Torx screw 3 T 15 Torx screw 4 Top cover trim T 20 Torx screw 2 Carrying handle Snap stud 4 To remove the trim ring slide the flat end of a soldering aid into the side slo...

Страница 12: ...e instrument so the top is down on the work surface and the bottom is facing you a Remove the four T 15 Torx screws that secure the bottom cover to the instrument b Remove the bottom cover from the in...

Страница 13: ...mounting hole a Remove the eleven T 15 Torx screws that secure the covers to the top and both sides of the chassis b Remove the seven T 15 Torx screws that secure the covers to the bottom of the chass...

Страница 14: ...ation Instructions 12 TDS6UP TDS7UP and CSA7UP Option CPU Upgrade Kit All left and right cover mounting holes are indicated as shown Left side cover Right side cover T 15 Torx screw 11 Figure 5 Cover...

Страница 15: ...Installation Instructions TDS6UP TDS7UP and CSA7UP Option CPU Upgrade Kit 13 Right side cover T 15 Torx screw 7 Left side cover Figure 6 Cover removal...

Страница 16: ...and are listed in the order presented H NLX board H CD drive bracket 1 Locate module to be removed Locate the NLX Board in the locator diagram Internal Modules Figure 7 on page 15 Additional modules t...

Страница 17: ...r board Front panel board Front panel keypad Floppy disk drive Display module assembly Power flex circuit Display adapter board NLX board Hard drive PA bus board Acquisition board Figure 7 Internal mo...

Страница 18: ...top of the hard CD drive bracket c Remove the five T 15 Torx screws that secure NLX board assembly to the chassis d Remove the five T 15 Torx screws that secure NLX board assembly to the rear chassis...

Страница 19: ...ve bracket Leave floppy drive cable attached Processor board edge connector Figure 8 NLX assembly removal 4 Remove the Riser Adapter and NLX Boards See Figure 9 on page 18 a Remove the screws that sec...

Страница 20: ...iscard the NLX board assembly 5 Remove the CD Drive bracket and Rom interface board See Figure 10 on page 19 a Remove the four 0 Phillips screws that secure the bracket to the CD Drive Remove the CD D...

Страница 21: ...e ribbon cable T 15 Torxdrive screw 2 Figure 10 CD drive and bracket removal Install This section provides instructions for reassembly of the instrument and reinstalling the operating software 1 Reins...

Страница 22: ...l the Applications software CD Follow the instructions provided with the Applications software CD Verify Operation This section contains instructions to check that the additional memory that you insta...

Страница 23: ...Installation Instructions TDS6UP TDS7UP and CSA7UP Option CPU Upgrade Kit 21 g End of document g...

Страница 24: ......

Отзывы: