Getting started
Protect your DUT
Use care when you connect the instrument Channel Output to your DUT (device
under test). To avoid damage to your DUT, the following preventive measures are
provided. Follow these steps to set the limit values for high level and low level.
1.
Push the Output Menu
bezel button.
2.
Push the Limit bezel
button.
3.
Push the High Limit bezel
button.
4.
Notice that in this
example, High Limit
is set to 5.000 V, and Low
Limit is set to -5.000 V.
5.
Use the numeric keys or
the general purpose knob
to set the High Limit to
50 mV and the Low Limit
to -50 mV.
6.
Push the front-panel
Sine button to display
the waveform parameter.
Con
fi
rm that High and
Low voltage levels were
changed.
NOTE.
You cannot enter any
values greater than 50 mV for
High level.
NOTE.
When you set limit values using the Output Menu, a level indicator is
displayed at the left end of the graph area.