SECTION
S
MAINTENANCE
PREVENTIVE MAINTENANCE
Air
Filter
Care must
be taken to assure free
ventilation of the Type
535A
inasmuch as some of the components are operated at
dissipation levels
such
that excessive interior temperatures
will
result without
adequate air
circulation. To assure free
passage
of air
the instrument must be placed so that the
air
intake
is not blocked and filter must be kept clean.
Moreover,
the side panels
and bottom cover must
be in
place
for
proper air circulation.
Do
not remove the covers
except during
maintenance.
A
washable EZ KLEEN filter is used at the air intake
port
of the instrument. Under normal operating conditions
the
filter should be
inspected and
cleaned if necessary
every
three to four months. More frequent inspection is
required when
the
operating conditions are
more severe.
The
following cleaning
instructions are issued by the filter
manufacturer:
(1)
If
grease
or dirt load is light, remove filter
from in
stallation
and rap
gently on hard surface to remove
loose dirt.
Flush remaining dirt or grease out of filter
with a
stream of hot water or
steam.
(2)
If load
is
too heavy for treatment described in (1), pre
pare
mild soap or detergent solution in pan or sink
deep
enough
to cover filter when laid flat. Agitate
filter
up
and down in solution until grease or dirt is
loosened
and floated
off.
(3)
Rinse
filter and let dry.
(4)
Dip
or spray filter with
fresh Filter Coat or Handi-
coater.
These
products
are available from the local representative
of the
Research Products Corporation and from most
air
conditioner
suppliers.
Fan
Motor
The
fan motor bearings
should be lubricated every three
or
four months with a
few drops of light machine oil (see
Fig. 5-1
.
Location of the fan motor lubrication points.
5-1
Содержание 535A
Страница 2: ......
Страница 4: ...Type 535A ...
Страница 28: ...Circuit Description Type 535A 4 2 Fig 4 1 Simplified Type 535A Vertical Amplifier ...
Страница 30: ...Circuit Description Type 535A 4 4 Fig 4 2 Simplified Time Base Trigger Circuit ...
Страница 32: ...Circuit Description Type 535A Fig 4 3 Simplified Time Base Generator 4 6 ...
Страница 34: ...Circuit Description Type 535A 4 8 Fig 4 4 Simplified Delay Pickoff Circuit ...
Страница 38: ...Circuit Description Type 535A Fig 4 6 Simplified Alternate Trace Operation Circuitry 4 12 ...
Страница 39: ...Circuit Description Type 535A 4 13 ...
Страница 41: ...Circuit Description Type 535A Fig 4 8 Simplified Low Voltage Power Supply 4 15 ...
Страница 42: ...Circuit Description Type 535A 4 16 Fig 4 9 Simplified Calibrator Circuit ...
Страница 44: ...Circuit Description Type 535A Fig 4 10 Simplified Cathode Ray Tube Circuit 4 18 ...
Страница 126: ...MRU ll IG 61 O Z ...
Страница 138: ...C897 R896 R891 R890 R889 R888 R887 R886 R885 AMPLITUDE CALIBRATOR SWITCH Bottom View 535A A ...
Страница 140: ...C t Aao 3 ELEV 1 TERM 27 TERM 2e TIME BASE B CHA S5 S TYPE 3 5 C S C S C C P E R E A T ER WIRING DIAGRAM ...
Страница 143: ...FIG 1 FRONT SWITCHES TVDC COCA ocril I iCrODC ...
Страница 144: ...70 ...
Страница 145: ...1 FIG 3 SWEEP CHASSIS HIGH VOLTAGE BOARD DELAY SWEEP CHASSIS ...
Страница 146: ...1 FIG 4 POWER CHASSIS RECTIFIER MOUNTING PLATE A ...
Страница 147: ...3 34 79 ...
Страница 148: ...TYPE 535A OSCILLOSCOPE ...
Страница 149: ......
Страница 150: ...FIG 7 CABINET FRAME RAILS ...
Страница 152: ...FIG 8 STANDARD ACCESSORIES 6 TYPE 535A OSCILLOSCOPE ...