Operating lnstructions-5110
GENERAL
OPERATING
INFORMATION
Intensity
Control
The
setting
of the INTENSITY control may affect the
correct
focus
of
the display. Slight adjustment of the
FOCUS
control
may be necessary when the intensity
level
is changed. To
protect the crt phosphor, do not turn the
INTENSITY
control
higher than necessary to provide a
satisfactory
display.
WARNING I
Damage to the
crt phosphor can
occur under
adverse
conditions. Avoid any condition where an
extremely bright, sharply
focused spot
exists on
the
crt.
Apparent trace intensity can
be improved by reducing
the ambient light level or using
a
viewing
hood. Also, be
careful
that
the INTENSITY control is not set too high
when changing
the time-base
unit
sweep rate from a fast
to
a slow sweep
rate, or when changing to the X-Y mode
of
operation.
Display
Focus
If
a well-defined
display cannot be
obtained with the
FOCUS control, even at low INTENSITY control settings,
re-setting
of
the internal astigmatism adjustment may be
required
(adjustment
must only be made
by qualified
service personnel).
To
check for proper setting of the astigmatism adjust
ment,
slowly turn
the FOCUS control through the op
timum
setting
with a signal displayed on the crt
screen. If
the astigmatism adjustment
is correctly set, the vertical
and
horizontal
portions of the trace will come into
sharpest
focus at the same position of the
FOCUS control.
Beam
Finder
The
BEAM FINDER switch provides a
means
of
locating
a display that overscans the viewing
area either
vertically
or horizontally. When the BEAM FINDER switch
is
pressed,
the display is
compressed within the graticule
area
and
the display intensity is increased. To locate and
reposition
an
overscanned display, use the following
procedure:
1. Press
the BEAM FINDER
switch, hold it in, then
increase
the
vertical and horizontal deflection
factors until
the
display is within
the graticule area.
2.
Adjust
the vertical
and horizontal position controls
to
center the display about the vertical and horizontal
centerlines.
3. Release
the BEAM FINDER switch; the display
should
remain within the viewing area.
Graticule
The
graticule
of
the
oscilloscope is marked on the
inside
of the faceplate
of
the crt providing accurate,
no
parallax
measurements. The
graticule is divided into
eight
vertical and ten
horizontal divisions; each division is 0.5-
inch
(1.27 centimeters)
square. In addition, each major
division
is divided into five
minor divisions.
The vertical
gain
and horizontal timing
of
the plug-in units are
calibrated to
the graticule so accurate measurements
can
be
made from the crt.
When
making time measurements from the graticule,
the center
eight divisions
provide the most accurate
time
measurements.
Position the start of the timing area to the
second vertical graticule line and set
the time-base unit so
the
end of the timing area falls between the second and
tenth vertical graticule lines.
Trace
Alignment
If
a free-running trace is not parallel with the horizontal
graticule lines, set the
TRACE ROTATION adjustment
(rear-panel
adjustment) as follows; Position the trace to
the center
horizontal
line and adjust the TRACE
ROTATION
adjustment so that the trace is parallel with
the horizontal graticule
lines.
Calibrator
Signal
The internal calibrator
of the oscilloscope provides a
convenient signal
source
for checking basic vertical gain
and
sweep timing. The calibrator
signal is also very useful
for
adjusting probe compensation,
as described in the
probe instruction
manual.
The output square-wave
voltage
is 400 millivolts,
within 1%, and the square-wave
current
is
4 milliamperes, within 1%. The frequency of the
square-wave
signal
is twice
the power-line frequency. The
signal
is obtained by clipping the probe to the loop.
1-5
Содержание 5110
Страница 6: ...5110 Fig 1 1 5110 Oscilloscope 2134 01 ...
Страница 22: ......
Страница 34: ......
Страница 42: ......
Страница 83: ...5110 I43XII3 2134 15 ...
Страница 84: ... i 143 I132 2134 15 BLOCK DIAGRAM ...
Страница 85: ... t 2 E I 5110 S LNHNOdWOD BOVJHaiNI ...
Страница 88: ...J4 O3 INTERFACE J INTERFACE A NOV 1978 ...
Страница 92: ...AUXILIARY BOARD 1143 2134 18 AUXILIARY BOARD ...
Страница 95: ...DEFLECTION AMPLIFIERs ...
Страница 102: ...LV POWERSUPPLY CALIB COMPONENTS A 4 L V Power Supply circuit board 5110 ...
Страница 107: ...SIGNALS OUT OPTION 7 ONLY SI 10 OPT 7 213 26 REV A FE BI979 SIGNALS OUT COPTION T ONLY n ...
Страница 114: ......
Страница 115: ...5110 OSCILLOSCOPE ...
Страница 116: ...FIG 2 MAINFRAME p 5110 OSCILLOSCOPE ...
Страница 117: ...1 ...
Страница 121: ...o ...
Страница 122: ...S 1 5110 OSCILLOSCOPE ...
Страница 123: ...13 FIG 4 RACKMOUNT CABINET 5110 OSCILLOSCOPE ...
Страница 124: ......