Quickly display a waveform (Autoset)
The Autoset function analyzes the signal characteristics and changes the instrument Horizontal, Vertical, and Trigger settings to
automatically display a triggered waveform. You can then make further changes to trigger and horizontal settings to view the
waveform point of interest.
1. Connect the probe with the signal of interest to the lowest-numbered channel. The signal can be analog or digital.
2. Connect any other associated signal(s) to available channel input(s).
3. Add the channel waveforms to the Waveform view.
Add a channel waveform to the display
4. Push the front-panel Autoset button. When using the Stacked Display mode, the instrument analyzes the signal
characteristics of the lowest-numbered displayed channel (analog or digital) and adjusts the horizontal, vertical, and trigger
settings accordingly to display a triggered waveform for that channel. Vertical scale is adjusted for all other active
waveforms to maximize ADC utilization.
When using the Overlay Display mode, the instrument adjusts the horizontal and trigger settings of the lowest-numbered
displayed channel to display a triggered waveform for that channel, and adjusts the vertical settings and position of all active
waveforms such that they are uniformly spaced on screen.
Autoset guidelines:
■
Autoset displays two or three cycles (depending on the detected signal) with the trigger level near the midlevel of the signal.
■
The trigger is set to type Edge, rising slope, DC coupling.
■
If no channels are displayed before pushing Autoset, the oscilloscope adds Ch 1 to the view whether it has a signal or not.
■
For digital signals, the oscilloscope analyzes and triggers on the lowest (LSB) digital channel with an active signal.
■
Autoset ignores math, reference, and bus waveforms.
■
A channel or waveform with a frequency less than 40 Hz is classified as no signal.
Operating basics
MSO54, MSO56, MSO58 Installation and Safety Manual
35
Содержание 5 Series
Страница 2: ......
Страница 6: ......
Страница 66: ...Cleaning the instrument 52 MSO54 MSO56 MSO58 Installation and Safety Manual ...
Страница 70: ...EMC safety and environmental compliance 56 MSO54 MSO56 MSO58 Installation and Safety Manual ...
Страница 76: ...Index 62 MSO54 MSO56 MSO58 Installation and Safety Manual ...
Страница 77: ...5 シリーズ ミックスド シグナル オシロスコープ MSO54 型 MSO56 型 MSO58 型 インストールおよび安全性に関するマニュアル P071351400 071 3514 00 ...
Страница 78: ......
Страница 82: ......
Страница 90: ...安全性に関する重要な情報 viii MSO54 型 MSO56 型 MSO58 型のインストールおよび安全性に関するマニュアル ...
Страница 128: ...本機の設定 36 MSO54 型 MSO56 型 MSO58 型のインストールおよび安全性に関するマニュアル ...
Страница 148: ...機器のクリーニング 56 MSO54 型 MSO56 型 MSO58 型のインストールおよび安全性に関するマニュアル ...
Страница 152: ...EMC 安全 環境に関する適合性 60 MSO54 型 MSO56 型 MSO58 型のインストールおよび安全性に関するマニュアル ...
Страница 157: ...5 系列混合信号示波器 MSO54 MSO56 MSO58 安装和安全手册 P071351400 071 3514 00 ...
Страница 158: ......
Страница 159: ...5 系列混合信号示波器 MSO54 MSO56 MSO58 安装和安全手册 www tek com 071 3514 00 支持 5 系列 MSO 产品固件 V1 0 以及更新版本 ...
Страница 162: ......
Страница 176: ...安装仪器 6 MSO54 MSO56 MSO58 安装和安全手册 ...
Страница 221: ...清洁仪器 清洁 使用干燥柔软的棉布清洁设备外部 请勿使用任何可能损坏触摸屏 外壳 控件 屏幕 标记或标签或者可 能渗入外壳的液体清洁剂或化学品 MSO54 MSO56 MSO58 安装和安全手册 51 ...
Страница 222: ...清洁仪器 52 MSO54 MSO56 MSO58 安装和安全手册 ...
Страница 226: ...电磁兼容 EMC 安全和环境合规性 56 MSO54 MSO56 MSO58 安装和安全手册 ...
Страница 232: ...索引 62 MSO54 MSO56 MSO58 安装和安全手册 ...