Operating
Instructions—
Type
3B5
Fig.
2-10. Measuring risetime.
Example.
Assume
that
the
horizontal
distance
between
the
10%
and
90%
points
is
four
divisions (see Fig.
2-10)
and
the
indicated
sweep
rate
is
0.1
μ
s/DIV.
Applying
the time
duration formula
to
risetime:
Risetime
(Time
Duration)
horizontal
distance
(divisions)
indicated
X
sweep
rate
Substituting
the
given
values:
Risetime
=
4 X
0.1
/xs
The
risetime
would
be
0.4
microsecond.
TABLE
2-4
Vertical
Display
(
Divisions)
10%
and
90%
points
4
0.4
division
5
0.5
division
6
0.6
division
7
0.7
division
8
0.8
division
Time-Difference
Measurements
The
calibrated
sweep
rate
of
the
Type
3B5
when
used
with
a
dual-trace
amplifier
unit
allows
measurement
of
time
difference
between
two
separate
events.
To
measure
time
difference,
use
the
following
procedure.
1.
Set
the
input coupling
switches
of
the
amplifier
unit
to
the
desired
coupling
positions.
2. Connect
the
reference
signal
to
the
channel
1
input
connector
and
the
comparison
signal
to
the
channel
2
input
connector.
The
reference signal
should
precede
the
compari
son
signal in
time.
Use
coaxial
cables
or
probes which
have
equal
time
delay
to connect
the
signals
to
the
input
con
nectors.
3.
If
the
signals
are
of
opposite
polarity,
invert
the
display
on
one
channel
(signals
may be of
opposite
polarity due
to
180°
delay;
if
so, take
into
account
in
final delay
calculation).
4.
Set
the
volts/division
switches
to
produce
four-
or
five-
division
displays.
5.
Set
the
Type
3B5
Trigger LEVEL
control for
a
stable
display
(trigger from
channel
1
only
or
externally
trigger
from
reference signal).
6. Set
the
MANUAL
TIME/DIV
switch
for
a
sweep
rate
which
shows
three
or
more
divisions horizontally between
the
two
waveforms.
7.
Adjust
the
amplifier
unit
position controls
to
center
each
waveform
(or
the
points
on
the
display
between
which
the measurement
is
made)
in
relation
to the
center
horizontal
line.
8.
Adjust
the
Type
3B5
POSITION
control
so
the
channel
1
(reference)
waveform
crosses
the
center
horizontal
line
at
a
vertical
graticule
line.
9.
Measure
the horizontal
difference
between the
time
measurement
points
on the
channel
1
waveform and
the
channel
2
waveform
(see
Fig. 2-11).
10.
Multiply
the
measured
difference by
the
sweep
rate
indicated
on
the
readout panel
to
obtain
time
difference.
Example.
Assume
that
the
sweep
rate
indication is
5
μ
s/
DIV
and
the
horizontal
difference
between
the
time
measure
ment points is
4.5
divisions
(see Fig. 2-11).
Using
the
formula:
horizontal
indicated
Time
Delay
=
difference
X
sweep
(divisions)
rate
Substituting
the
given
values:
Time
Delay
=
4.5
X
5
/xs
The
time
delay would
be
22.5 microseconds.
Channel 1
(Reference)
Channel
2
Fig.
2-11. Measuring
time difference
between two pulses.
2-16
Содержание 3B5
Страница 4: ...Fig 1 1 Type 3B5 Automatic Programmable Time Base unit Type 3B5...
Страница 15: ...Operating Instructions Type 3B5 TYPE 3B5 CONTROL SET UP CHART Fig 2 2 Control set up chart 2 7...
Страница 48: ...CO I o Fig 3 13 Delay and Timing Circuit logic block diagram Circuit Description Type 3B5...
Страница 61: ...GO i GO GO Fig 3 22 Seek Ciicuit Logic block diagram Circuit Description Type 3B5...
Страница 70: ...u k KJ Fig 3 29 Circuit conditions for Manual Mode operation Circuit Description Type 3B5...
Страница 71: ...w K w Fig 3 30 Circuit conditions for Seek Mode operation Circuit Description Type 3B5...
Страница 72: ...w I u U Fig 3 31 Circuit condition for External Mode operation Circuit Description Type 3B5...
Страница 88: ...Maintenance Type 3B5 Fig 4 9 Location of components on Logic Card 4 14...
Страница 89: ...u Oi Fig 4 10 Location of components on Counter Card Maintenance Type 3B5...
Страница 92: ...NOTES I...
Страница 104: ...NOTES...
Страница 106: ...Calibration Type 3B5 Fig 6 1 Recommended calibration equipment...
Страница 160: ......
Страница 176: ...J400 RtADOUT BOARD 3B5 PLUG IN A READOUT...
Страница 182: ...397 R E A D O U T B O A R D 10 6b READOUT BOARD...
Страница 184: ...FIG 1 FRONT SWITCHES TYPE 3B5 AUTOMATIC PROGRAMMABLE TIME BASE...
Страница 185: ...FIG 2 CHASSIS REAR 3 GS to TYPE 3B5 AUTOMATIC PROGRAMMABLE TIME BASE...
Страница 186: ...OPTIONAL ACCESSORIES...