Maintenance—2246 1Y and 2246 Mod A Service
2. Check Readout Request pulse (RO REQ, U2410
pin 14).
3. Check Readout Blanking signal ( RO BLANK,
U2410 pin 16).
4. Check activity of Readout Processor (U2400).
5. Check
outputs of
Vertical
and Horizontal
Readout
DACs
(U2412
and
U2413,
respectively).
6. Check
outputs of
Vertical
and Horizontal
Readout Mixers
(U2416A and U2416B, re
spectively) and multiplexers (U2414 and U2415,
respectively).
Schematic Diagram 10—SWITCH BOARD AND
INTERFACE
1. Run the EXERCISE SWITCHES exerciser and
check each of the front panel switches for cor
rect operation. The circuit number of the latest
switch pressed is displayed in the readout.
Pressing END exits the exerciser; pressing
CLEAR
MEAS’ MT
terminates
the
Service
Program.
2. Run the EXERCISE LEDS exerciser and check
that each of the front panel LEDS may be turned
on. The circuit number of the lighted LED is dis
played in the readout. Circuit numbers DS2016,
DS2017 ,' DS2018, DS2019, DS2024, DS2040,
and DS2049 do not correspond to any LEDs on
the front
panel.
Pressing
END
exits the
excerciser.
Schematic Diagram 11—ADC, DAC SYSTEM
1. Run EXERCISE DACS (under EXERCISER, PROC
BOARD, and A TO D menus) and probe the
demultiplexed outputs of U2303 (Diagram 11)
and each of the sam ple-and-hold circuits for
proper operation.
2. Run EXERCISE PORTS (under EXERCISER, PROC
BOARD, and A TO D menus) and trace the signal
path
of
any
problems
with
the
A -to -D
Converter.
Schematic Diagram 12-POW ER SUPPLY
W A R N IN G I
For safety reasons, an isolation transformer
must be connected whenever troubleshooting
is done in the Preregulator and Inverter Power
Supply sections of the instrument.
1. If the fuse blows, check that Q2201 is not
shorted. (If a variac is available, slowly increase
the line voltage from 0 V until the voltage across
C2202 is about 40 V. If the same voltage is
across C2203, Q2201 is probably shorted.)
2. If the Preregulator fails to come up (44 V not
present across C2203):
a. Check +DC at the output of the line rectifier
bridge (across C2202) for approximately
( VacRMS X 1.414).
b. Check the Start-up circuit. The voltage
across C2204 should ramp up to about 20 V,
at which point Q2204 and Q2211 turn on to
supply voltage to pin 10 of U2201.
c. Check the Preregulator circuit. Voltage
pulses with a repetition rate of about 25 >xs
should be present on pin 8 of U2201 when
ever supply voltage is present on pin 10.
3. If the power supply is in the chirp mode (con
tinually restarting and shutting down), excessive
loading of the +44 V supply is probable.
TROUBLESHOOTING MEASUREMENT
ERRORS
When certain measurement malfunctions occur, the
symptoms usually indicate the circuit components
that may be causing the problems. Read the
following text to become familiar with the terms used
in describing a measurement failure problem and
the setup conditions needed to determine the
symptoms. Then use Table 6-9 to check for
measurement malfunction symptoms and probable
causes.
1. Verify all the following conditions and read the
definitions before attempting to use Table 6-9
for locating the source of m easurem ent-error
problems.
6-25
Содержание 2246 1Y
Страница 13: ...2246A Service 7062 01 X The 2246 1Y or 2246 Mod A Portable Oscilloscope ...
Страница 35: ......
Страница 69: ...Theory of Operation 2246 1Y and 2246 Mod A Service 15 V 6081 07 3 32 Figure 3 4 Simplified Sweep Circuit ...
Страница 91: ...Theory of Operation 2246 1Y and 2246 Mod A Service 6081 12 6557 99 3 54 Figure 3 9 Power Supply block diagram ...
Страница 139: ......
Страница 185: ......
Страница 187: ......
Страница 278: ...Figure 9 5b Detailed 2246 1Y or 2246 Mod A block diagram part 2 R E ...
Страница 287: ......
Страница 304: ...A D D J U N 1991 ...
Страница 311: ...2246 1Y and 2246 Mod A Service WAVEFORMS FOR DIAGRAM 1 0 V r l III B f e I l i 6555 39 ...
Страница 314: ...15 14 13 12 11 10 9 8 7 6 5 12 11 10 9 8 7 AT117 A TI 271 1 2 3 4 5 6 6555 70 Figure 9 8 Hybrid pin identifiers ...
Страница 319: ......
Страница 320: ......
Страница 321: ...2246 1Y and 2246 Mod A Service WAVEFORMS FOR DIAGRAM 2 SET READOUT CONTROL CCW OFF 6555 40 ...
Страница 323: ......
Страница 324: ......
Страница 326: ...A B C P E F G ...
Страница 327: ......
Страница 331: ......
Страница 337: ......
Страница 340: ......
Страница 343: ...C l rti ...
Страница 344: ...WAVEFORMS FOR DIAGRAM 5 2246 1Y and 2246 Mod A Service HORIZ MODE A A SEC DIV 2M S HOLDOFF MIN CCW ...
Страница 345: ...HORIZ MODE ALT A SEC DIV 2M s B SEC DIV 5 mS HOLDOFF MIN DELAY INTENSIFIED ZONE STARTS MIDSCREEN ...
Страница 347: ...BEV JUNE 1991 7062 18 ...
Страница 349: ...2246 1Y and 2246 Mod A Service WAVEFORMS FOR DIAGRAM 6 6555 43 I ...
Страница 354: ...A L B i C 1 D 1 E i F i G 1 2 3 4 5 6 7 8 2246 1Y AND 2246 MOD A _________A fc A A REV JUNE 1991 7062 19 ...
Страница 355: ...I BOARD LOCATION 8K 8J 8H 7H 8H 8H 7J 8D 7H 8H 8J 8J 7K 8K 10D 6L 6K 6L 6K 6G 5H I ...
Страница 362: ......
Страница 372: ...2246 1Y and 2246 Mod A Service WAVEFORMS FOR DIAGRAM 9 MORE ...
Страница 373: ... 6555 72 6557 88 ...
Страница 375: ......
Страница 376: ...SCHEM LOCATION BOARD LOCATION 2E 2B 7F 4B 4J 5D 3J 5C 4L 6D 3L 6C 5L 7D 3L 7D 3M 7D 5M 7D IB 1A 1C 1A 2B 1A 3B 1A ...
Страница 380: ...WAVEFORMS FOR DIAGRAM 10 ...
Страница 387: ...WAVEFORMS FOR DIAGRAM 11 6555 73 6557 48 ...
Страница 394: ...WAVEFORMS FOR DIAGRAM 12 2246 1Y and 2246 Mod A Service i f I S 1 f c i 4 i ...
Страница 395: ...WAVEFORMS FOR DIAGRAM 12 cont 2246 1Y and 2246 Mod A Service ...
Страница 397: ......
Страница 398: ......
Страница 400: ...REV JUNE 1991 7062 39 ...
Страница 401: ......
Страница 403: ......
Страница 404: ......
Страница 406: ...B 2246 IV AND 2246 MOD A ...
Страница 407: ......
Страница 408: ......
Страница 414: ... _ 5 ...
Страница 415: ...2246 1Y 2246 MOD A ...
Страница 416: ......
Страница 423: ...2246 1Y 2246 MOD A ...
Страница 424: ...2246 1Y 2246 MOD A ...
Страница 425: ......
Страница 433: ......