www.tek-trol.com
8
The sound passes through the pipe or liquid diagonally. The selection of the right method
depends on the characteristics of the liquid.
2.3
Specifications
2.3.1
Technical Specifications for Hand-Held Device
Accuracy
±1% of reading at rates >0.2 mps
Velocity Range
0.03 to 100ft/sec
Repeatability
0.2%
Resolution
0.0003 ft/s
Measurement Period
0-999 seconds, user-configurable
Measurement Principle
Transit Time Ultrasonic Flow Meter
Media
All liquids with solids of <5 % and a flow of >0.19pm
Flow Units
Matric
Measuring Unit
Cubic meter
m³
Liter
l
Gallon
gal
Imperial Gallon (UK)
igl
Million USA Gallons
mgl
Cubic foot
cf
Barrel (USA)
bal
Imperial Barrel (UK)
ib
Oil Barrel
ob
The time can be per day [/d], per hour [/h], per minute [/m]
and per second [/s]
Weight
Portable transmitter weight 514g
Package with accessories weight 6kg