background image

 IL573 Tek-ENTRY

®

 Telephone Entry System Phone-Line Version Manual • 1

Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

General Features

Tek-ENTRY

®

 Telephone Entry Systems are designed for easy operation and accommodate

1–750 suites with 7-, 10- or 11-digit phone numbers. The system has many sophisticated
features built in, such as:

All programming is done via the system keypad.

EEPROM Memory retains programmed information during total power failure.

Two programmable relay outputs control door strikes, gates, cameras, etc.

System operates with both touchtone and rotary pulse phones.

Automatic call termination after 8 seconds of dial tone detection.

Microphone Mute prevents unauthorized entry using a tone generator.

Variable tenant code length: 1, 2, 3 or 4 digits.

One keyless entry code per tenant, plus five for use by building management.

Tenant codes can be actual suite numbers or coded for security purposes.

May be programmed with any combination of 7, 10 or 11 digit phone numbers.

Special Features

Postal Service Lock

Provision for the installation of a postal service lock is available on the rear of the system
enclosure’s control panel.

Door Timer Cut-Off (Tailgate Prevention)

This feature requires the installation of a “Normally Open” switch contact that closes
when the entry door has been opened. A magnetic contact, as used in security systems, is
acceptable for this application, provided that it is a “Normally Open” type. (Most security
door contacts are of the “Normally Closed” type.) When the electric door strike is released,
the door remains open for the period of time that has been programmed. When the door
timer cut-off feature is used, the door strike de-energizes as soon as the system senses
that the entry door has been opened. This causes the door to lock when it closes, regardless
of the programmed time. The door strike is therefore energized only as long as necessary,
to prevent unauthorized entry of individuals who follow behind the visitor (tailgating).

Fire Alarm (Emergency) Input

Connecting a “Normally Open” alarm contact from the building fire alarm system causes
the electric door strike to pulse on and off in the event of a fire (emergency) situation.
This effectively leaves the entry door unlocked for the duration of the emergency.

Multiple Entrances

Accommodating multiple entry doors is a built-in feature of the Tek-ENTRY

®

 Telephone

Entry Systems. Up to 20 entry systems can be interconnected without additional switching
equipment, and all systems can be connected to one common telephone line. One additional
pair of wires, parallel connected to terminals “ME” and “G” of all entry systems, is
required. When one entry panel is in use, the other panels are temporarily disabled and
display a “SYSTEM IN USE” message. (

NOTE: 

Each entry panel must be independently

powered and programmed, and requires a telephone extension jack at that location.)

Night Service

This feature redirects all entry system calls to a pre-designated telephone number (guard
phone). When this feature is enabled (by entering “*456”), the entry system displays the
“Night Service On” message. To return to normal operation, re-enter “*456”.

Wiegand Data Output

This feature connects the Tek-ENTRY

®

 Telephone Entry System to a card access system

with a Wiegand 26-bit input. When a tenant approves a visitor, the tenant’s code is sent
to the card access system, causing the door to open.

System Introduction ———————————————————

Содержание Tek-ENTRY TE903A

Страница 1: ...n Operation Installation and Service Manual IL573 SECTION A Rev 12 12 2009 www tektone com Phone 828 524 9967 Toll Free 800 327 8466 Tech Support Option 2 Sales Option 3 277 Industrial Park Road Frank...

Страница 2: ...kTone Sound Signal Mfg Inc TekTone Sound Signal Mfg Inc assumes no responsibility or liability for any errors or inaccuracies that may appear in this documentation TekTone the TekTone logo Tek Call Te...

Страница 3: ...s Entry Codes 6 View Keyless Codes 6 New Master Code 6 7 10 or 11 Digit Programming 6 Pulse or Tone Dialing 7 Door Open Time 7 Talk Time 7 Night Service Guard Telephone 7 Rotary Phones 7 Guard Telepho...

Страница 4: ......

Страница 5: ...been programmed When the door timer cut off feature is used the door strike de energizes as soon as the system senses that the entry door has been opened This causes the door to lock when it closes r...

Страница 6: ...ring Diagram and Figure 3 Handset Panel Wiring Diagram 1 Mount the system enclosure to the wall in the location closest to the building s controlled entry point Refer to Figure 5 Frame and Housing Ins...

Страница 7: ...OR STRIKE TRANSFORMER D C SILENT DOOR STRIKE A C BUZZING DOOR STRIKE NO C NC PL TC G FA ME AUXILIARY RELAY MOMENTARY CONTACT POSTAL LOCK DOOR TIMER CUTOFF COMMON FIRE ALARM INPUT MULTIPLE ENTRANCE N O...

Страница 8: ...al Mfg Inc All Rights Reserved Figure 2 Hands Free Panel Wiring Diagram Figure 3 Handset Panel Wiring Diagram HANDSET PANEL M S PCB Rear View RED BLACK NOT CONNECTED BROWN RED ORANGE YELLOW GREEN BLUE...

Страница 9: ...ial codes and keyless entry codes These sheets will be required for programming as well as when changes are to be made Complete the Tek ENTRY Telephone Entry System Programming Worksheet and ensure th...

Страница 10: ...s the key to return to the programming menu 4 If desired press the key to end program mode View Keyless Codes This section allows the review and or deletion of keyless entry codes 1 When the programmi...

Страница 11: ...uction Special Features section for more information 1 When the programming menu displays DOOR TIME press the key The message DOOR OPEN TIME will appear 2 Enter a two digit time in seconds and press t...

Страница 12: ...ion volume levels are factory preset for normal operations The levels can be increased or decreased by adjusting the potentiometers located along the bottom of the system controller behind the front d...

Страница 13: ...n conjunction with coin telephone service The Tek ENTRY Telephone Entry System is equipped with a USOC RJ11C standard miniature modular jack that is designed to plug directly into a modular jack Notif...

Страница 14: ...nal and safety requirements The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be co...

Страница 15: ...one Line Version Manual 11 Copyright TekTone Sound Signal Mfg Inc All Rights Reserved Figure 4 PM900 Control Unit Mounting Template Drill Here Drill Here THIS EDGE TO SIDE OF HOUSING THIS EDGE TO SIDE...

Страница 16: ...nd housing information Directories supplied separately TE Series Master Housing Frame Chart OH192 Housing OF192 Frame Frame Bracket AM190D Directory Vandal Resistant Screws TE905A Notes 1 Refer to fra...

Страница 17: ...s the programming menu B Press the 1 key to scroll up or press the 3 key to scroll down the menu screen to the desired function C Press the key to select the desired function when it is displayed on t...

Страница 18: ...ephone Entry System Phone Line Version Manual Copyright TekTone Sound Signal Mfg Inc All Rights Reserved Tek ENTRY Telephone Entry System Directory Worksheet Suite Tenant Name Telephone Tenant Dial Co...

Страница 19: ...one Entry System Phone Line Version Manual 15 Copyright TekTone Sound Signal Mfg Inc All Rights Reserved Tek ENTRY Telephone Entry System Directory Worksheet Suite Tenant Name Telephone Tenant Dial Co...

Страница 20: ...ephone Entry System Phone Line Version Manual Copyright TekTone Sound Signal Mfg Inc All Rights Reserved Tek ENTRY Telephone Entry System Directory Worksheet Suite Tenant Name Telephone Tenant Dial Co...

Страница 21: ...one Entry System Phone Line Version Manual 17 Copyright TekTone Sound Signal Mfg Inc All Rights Reserved Tek ENTRY Telephone Entry System Directory Worksheet Suite Tenant Name Telephone Tenant Dial Co...

Страница 22: ...ephone Entry System Phone Line Version Manual Copyright TekTone Sound Signal Mfg Inc All Rights Reserved Tek ENTRY Telephone Entry System Directory Worksheet Suite Tenant Name Telephone Tenant Dial Co...

Страница 23: ...or The call will automatically cut off after a preprogrammed time period If you want to allow your visitor to enter simply dial or press 9 on your telephone This will unlock the entrance to your build...

Страница 24: ......

Отзывы: