![TEKTELIC Communications T0005982 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/tektelic-communications/t0005982/t0005982_user-manual_1077275019.webp)
LoRa Agriculture Sensor User Guide
T0005978_UG
Version # 1.9
TEKTELIC Communications Inc.
Confidential
Page 19 of 22
5
Operation, Alarms, and Management
5.1
Configuration
The Agriculture Sensor supports a full range of Over-the-Air (OTA) configuration options.
Specific technical details are available in the Agriculture Sensor Technical Reference Manual.
All configuration commands need to be sent OTA during a sensor’s downlink windows.
5.2
Default Configuration
The default configuration of the Soil Surface Mount Sensor for reporting transducer readings
includes the following:
Table 3: Default Configuration - Soil Surface Mount
Seconds per Core Tick
900 (15 min)
Ticks per battery voltage measurement
96 (24-hours)
Ticks per Ambient Temperature
1 (15 min)
Ticks per Ambient Relative Humidity
1 (15 min)
Ticks per Soil Moisture
1 (15 min)
Ticks per Soil Temperature
1 (15 min)
Ticks per Ambient Light
1 (15 min)
The default configuration of the Elevated Mount Sensor for reporting transducer readings
includes the following:
Table 4: Default Configuration - Elevated Mount
Seconds per Core Tick
900 (15 min)
Ticks per battery voltage measurement
96 (24-hours)
Ticks per Watermark 1
1 (15 min)
Ticks per Watermark 2
1 (15 min)
Ticks per Ambient Light
1 (15 min)
5.3
LED Behaviour
The LED’s are located on the top of the Agricultural Sensor. See Figure 8.