background image

TFP-1240 

Analogue Addressable Repeater Panel

 

TFP-1245 

Analogue Addressable Repeater Panel 

 with 72 Zones Indicators 

Installation & Operating Guide 

 

Yayın Tarihi: 

13/04/2018 

Rev:00 

 

Important Warnings 
General 

 

Before using the device read this manual carefully. Keep it just in case of necessity. 

 

Abide all the rules and precautions stated in the manual. Follow all the instructions one by one.

 

 

 

Keep the devices away from water and moisture 

 

Conditions 

Do not energize the device above or below the given limits of extreme hot or cold conditions, 

Temperature

Between

 -

10°C and +55°C

 

Relative Humidity: 

%95 RH max

 

 

Service 

Do not try to fix the device on your own. Removal of cover may end up with electricity shock. 

 
In case of any defect or malfunction, contact with  your dealer or  with authorized service. All the technical 

interventions have to be done by technicians of company. 

 
 

 
 
 

Malfunctions that require technical service 

In case of any malfunction or below conditions contact with your authorized service,  

 

When Mains cable or the plug is harmed,  

 

Contact of device with a fluid,  

 

Exposure of rain and water,  

 

Fell down of device or harmed outer cover,  

 

Serious performance fall on the device,  

 

Depending on the instructions stated in manual, if your device not working properly 

Contact with your authorized service in such terms. 

 

Maintenance on your own  

Do not try to fix the device on your own. Removal of cover may end up with electricity shock. In case of any 

defect or malfunction, contact with your dealer or with authorized service. All the technical interventions have 
to  be  done  by  technicians  of  company.  Device  must  be  cleaned  up  with  a  dry  fabric.  No-chemicals  are 

allowed for cleaning. 

 

Transportation 

Device must be carefully transported avoiding all physical bump, stroke and possible fluid entry. Malfunctions 

that caused by improper transportation is not under warranty.  

 

Human and Environmental Health 

This device contains no chemical or biological elements that could harm human condition.  

 

 

 General Features

 

 

 

Easy to read, 240 * 64 wide LCD graphic display 

 

User-friendly interface for easy viewing of alarms, faults and warnings 

 

Easy connection with main panel 

 

Real-time, stable communication with panel thanks to RS-485 communication structure 

 

Cable connection distance up to 1 Km with main panel 

 

Sturdy body design, stylish design 

 

72 LED Indicators showing alarms and error conditions on a zone basis 

 
 

 
 

 

             

                           

 

 TFP-1240

 

Analogue Addressable Repeater Panel   TFP-1245

 

Analogue Addressable Repeater Panel 

                                             with 72 Zones Indicators 

 

 

Technical Specifications 

 

TFP-1240 

TFP-1245 

Zones Indicators

 

72 zones 

Power Input 

24±4 VDC

 

Weight 

2,6 kg 

3,9 kg 

Dimensions (mm) 

230 x 386 x 40 mm 

350 x 386 x40 mm 

Color 

RAL7305 TEXTURE 

Temperature 

10C ~ 55C 

Humidity 

 Max 95% RH 

IP Class 

IP30 

 

 

 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 

 
 

 

Warning:

 Do not attempt to remove the electronic board from its plastic case. The electronic board is 

closed for your safety. Users should avoid from interference. 

 

Warning: 

The product only works with TFP-121x, TFP-122x and TFP-123x Analogue Addressable 

Fire Alarm panels. 