TFP-1240
Analogue Addressable Repeater Panel
TFP-1245
Analogue Addressable Repeater Panel
with 72 Zones Indicators
Installation & Operating Guide
Yayın Tarihi:
13/04/2018
Rev:00
Important Warnings
General
✓
Before using the device read this manual carefully. Keep it just in case of necessity.
✓
Abide all the rules and precautions stated in the manual. Follow all the instructions one by one.
✓
Keep the devices away from water and moisture
Conditions
Do not energize the device above or below the given limits of extreme hot or cold conditions,
Temperature
:
Between
-
10°C and +55°C
Relative Humidity:
%95 RH max
Service
Do not try to fix the device on your own. Removal of cover may end up with electricity shock.
In case of any defect or malfunction, contact with your dealer or with authorized service. All the technical
interventions have to be done by technicians of company.
Malfunctions that require technical service
In case of any malfunction or below conditions contact with your authorized service,
✓
When Mains cable or the plug is harmed,
✓
Contact of device with a fluid,
✓
Exposure of rain and water,
✓
Fell down of device or harmed outer cover,
✓
Serious performance fall on the device,
✓
Depending on the instructions stated in manual, if your device not working properly
Contact with your authorized service in such terms.
Maintenance on your own
Do not try to fix the device on your own. Removal of cover may end up with electricity shock. In case of any
defect or malfunction, contact with your dealer or with authorized service. All the technical interventions have
to be done by technicians of company. Device must be cleaned up with a dry fabric. No-chemicals are
allowed for cleaning.
Transportation
Device must be carefully transported avoiding all physical bump, stroke and possible fluid entry. Malfunctions
that caused by improper transportation is not under warranty.
Human and Environmental Health
This device contains no chemical or biological elements that could harm human condition.
General Features
✓
Easy to read, 240 * 64 wide LCD graphic display
✓
User-friendly interface for easy viewing of alarms, faults and warnings
✓
Easy connection with main panel
✓
Real-time, stable communication with panel thanks to RS-485 communication structure
✓
Cable connection distance up to 1 Km with main panel
✓
Sturdy body design, stylish design
✓
72 LED Indicators showing alarms and error conditions on a zone basis
TFP-1240
Analogue Addressable Repeater Panel TFP-1245
Analogue Addressable Repeater Panel
with 72 Zones Indicators
Technical Specifications
TFP-1240
TFP-1245
Zones Indicators
X
72 zones
Power Input
24±4 VDC
Weight
2,6 kg
3,9 kg
Dimensions (mm)
230 x 386 x 40 mm
350 x 386 x40 mm
Color
RAL7305 TEXTURE
Temperature
10C ~ 55C
Humidity
Max 95% RH
IP Class
IP30
Warning:
Do not attempt to remove the electronic board from its plastic case. The electronic board is
closed for your safety. Users should avoid from interference.
Warning:
The product only works with TFP-121x, TFP-122x and TFP-123x Analogue Addressable
Fire Alarm panels.