Teka TKD 1270 Скачать руководство пользователя страница 11

 

 

Service Manual 

SPA WASHING MACHINES (TKD) 

 

Service Manual: 

MSWM15043 EN 

 

                                     

   

- 10 -

 

6.

 

 Main components 

 

  

 

 
 
 
 
 

Inlet valves 

Supply voltage:  230 V. 
Impedance: 

 3 - 6 

KΩ

 

 

 

 

Drain pump 

Supply voltage: 230 V 
Impedance:  

≈ 

150 - 250 

 

 

 

Heating element 

Supply voltage: 230 V 
Rated power:  1800W 
Resistance: 

 20-

35 Ω.

 

 

 

 
 
Dryer heating element 

Supply voltage: 230 V 
Rated power:  1200W 
Resistance: 

 40-

55 Ω.

 

 

 

 
 
 
 

Temperature sensors 

Resistance:  

4

’8

 

KΩ 

 at  25ºC 

Содержание TKD 1270

Страница 1: ...43 EN updated 26 03 2020 SPA WASHING MACHINES TKD Contents 1 General description 1 2 Wiring diagrams 2 3 Service Test 5 4 Autotest 8 5 Errors 9 6 Main components 10 7 TKD 1270 TKD 1280 TKD 1480 TKD 14...

Страница 2: ...codes are displayed and their meaning and also the procedure to enter the auto test with a complete description of their phases There are three different types of appliances TKD 1270 TKD 1280 TKD 1480...

Страница 3: ...Service Manual SPA WASHING MACHINES TKD Service Manual MSWM15043 EN 2 2 Wiring diagrams 2 1 TKD 1270 TKD 1280 TKD 1480...

Страница 4: ...Service Manual SPA WASHING MACHINES TKD Service Manual MSWM15043 EN 3 2 2 TKD 1490...

Страница 5: ...Service Manual SPA WASHING MACHINES TKD Service Manual MSWM15043 EN 4 2 3 TKD 1610 WD...

Страница 6: ...ed only once although more than once has occurred If there are not any errors display will show E00 To delete the stored errors you must press simultaneously K5 and K6 for 3 seconds A beep will be hea...

Страница 7: ...urns back to the service menu K2 K1 Inlet valve Pressing K8 display will show UU Pressing once more K8 display will show U1 and pre wash valve will be activated for 3 seconds Pressing K1 display will...

Страница 8: ...yer sensor temperature y Out temperature for the sensor located in the exit NOTE in case of failure with one of the dryer sensors the appliance does not show any error K2 K1 Non applicable K2 Autotest...

Страница 9: ...U4 7 Shows temperature water sensor 8 Shows pressure switch value 9 Activates sequence for inlet valves U1 U2 U12 10 Activates heating element HEA 11 Activates drain pump PUP 12 Activates motor 50 rp...

Страница 10: ...nt error Heating element damaged E37 Failure related to the sensor of the outlet dryer duct Check sensor value wiring and connectors E38 Failure related to the sensor of the inlet dryer duct Check sen...

Страница 11: ...et valves Supply voltage 230 V Impedance 3 6 K Drain pump Supply voltage 230 V Impedance 150 250 Heating element Supply voltage 230 V Rated power 1800W Resistance 20 35 Dryer heating element Supply vo...

Страница 12: ...k the next Terminals 5 10 1 3 ohm Terminals 8 9 3 15 ohm Terminals 6 7 0 25 ohm Terminals 3 4 48 ohm Motor inverter Cannot be checked Pressure switch This is an electronic one so it cannot be directly...

Страница 13: ...ing the test To launch it switch on the appliance and press one by one K3 K5 K3 K5 buttons This operation must be done in the first 30 seconds after switching on the washing machine K1 y K2 buttons le...

Страница 14: ...To launch it switch on the appliance and press one by one K3 K5 K3 K5 buttons This operation must be done in the first 30 seconds after switching on the washing machine K1 y K2 buttons let us move be...