09
Instruction Manual
Operation Continued
00
oc
nloc
Hold the key
K/
K for 2s under the unlocking state, the system
enters the locking state and gives a buzzing sound of locking.
Hold the key
K/
K for 2s under the locking state, the system
enters the unlocking state and gives a buzzing sound of unlocking.
The system enters the locking state automatically without any key operation
for 30s.
cept that door opening alarm and fault alarm can be relieved under the
locking state as well, the following key operations must be operated under
the unlocking state. or any operation under the locking state, a buzzing
sound of wrong operation will ring.
Settin s o re ri eratin c am er
em erature settin o re ri eratin c am er
Press the key
.T
P to select the area of refrigerating temperature and
then press the key
.T
P to adjust the temperature of refrigerating
chamber; the temperature drops 1
℃
for pressing the key
.T
P once;
press the key
.T
P again after the temperature reaches 2
℃
, the
refrigerating chamber is set to 8
℃
. The temperature setting of refrigerating
chamber varies between 2 8
℃
, which will be effective upon locking.
Settin s o ree in c am er
em erature settin o ree in c am er
Press the key
.T
P to select the freezing temperature area and then
press the key
.T
P to adjust the temperature of freezing chamber; the
temperature drops 1
℃
for pressing the key
.T
P once; press the key
.T
P again after the temperature reaches -24
℃
, the freezing chamber
is set to -1
℃
and the temperature setting varies between -24 -1
℃
, which
will be effective upon locking.
o e settin
Press the key
D , the corresponding modes will be circulated as below
When the refrigerating chamber is on, cycle settings S P
S P
S P
/S P
V
T
S P
When the refrigerating chamber is off, cycle settings S P
V
T
S P
nder the S P
mode, the refrigerating chamber defaults to 2
℃
automatically; upon e iting the S P
mode, the setting temperature
of refrigerating chamber will restore to that before the S P
mode.
nder the S P
mode, the freezing chamber defaults to -24
℃
automatically; upon e iting the S P
mode, the setting temperature of
freezing chamber will restore to that before the S P
mode.
ist o ault o es
00
rror ode
1
2
4
5
7
H
Description
Temperature sensor failure of refrigerating chamber
Temperature sensor failure of freezing chamber
ailure of defrosting sensor in refrigerating chamber
ailure of freezing defrosting sensor
ommunication ailure
ailure of circulating temperature
Humidity sensor failure
nder the V
T
mode, the refrigerating chamber defaults to closed while
the freezing chamber defaults to -18
automatically;
Upon exiting the VACATION mode, the setting temperature of
refrigerating chamber and freezing chamber will both be restored to those
before the VACATION mode.