INSTALLATION
8) ELECTRICAL CONNECTION
The electrical connections of the appliance
must be carried out in compliance with the
provisions and standards in force.
Before connecting the appliance, check that:
- the voltage matches the value shown on the
specification plate and the section of the wires of
the electrical system can support the load, which
is also indicated on the specification plate.
- The electrical capacity of the mains supply
a n d c u r r e n t s o c k e t s s u i t t h e m a x i m u m
power rating of the appliance (consult the
data label applied to the underside of the
hot plate).
- The socket or system has an efficient earth
connection in compliance with the provisions and
standards in force. The manufacturer declines all
responsibility for failing to comply with these
provisions.
When the appliance is connected to the
electricity main by a socket:
- fit a standard plug “C” suited to the load indicated
on the data label to the cable. Fit the wires
following figure 18 - 19 - 20 , taking care of
respecting the following correspondences:
Letter L (live) = brown wire;
Letter N (neutral) = blue wire;
earth symbol
= green - yellow wire.
- The power supply cable must be positioned so
that no part of it is able to reach an temperature
of 90 °C.
- Never use reductions, adapters of shunts for
connection since these could create false contacts
and lead to dangerous overheating.
- The outlet must be accessible after the built-in.
When the appliance is connected straight to the
electricity main:
- install an omnipolar circuit-breaker between the
appliance and the electricity main. This circuit-
breaker should be sized, in compliance with
current installation regulations.
- Remember that the earth wire must not be
interrupted by the circuit-breaker.
- For optimum safety, the electrical connection may
also be protected by a high sensitivity differential
circuit- breaker.
You are strongly advised to fix the relative yellow-
green earth wire to an efficient earthing system.
Before performing any service on the electrical
part of the appliance, it must absolutely be
disconnected from the electrical network.
Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our burners do not require primary air
adjustment.
9) TAPS
“Reduced rate” adjustment
- witch on the burner and turn the relative knob to
the “Reduced rate” position (small flame fig. 17).
- Remove knob “M” (fig. 13 and 14) of the tap,
which is simply pressed on to its rod. The by-
pass for minimal rate regulation can be: beside
the tap (fig. 13) or inside the shaft. In any case,
to access to regulation, it can be done trought
the insertion of a small screwdriver ‘’D’’ beside
the tap (fig. 13) or in the hole ‘’C’’ inside the shaft
of the tap (fig 14). Turn the throttle screw to the
right or left until the burner flame has been
adequately regulated to the “Reduced rate”
position.
The flame should not be too low: the lowest small
flame should be continuous and steady. Re-
assemble the several components.
It is understood that only burners operating
with G20 gas should be subjected to the above
mentioned adjustments. The screw must be
fully locked when the burners operate with G30
or G31 (turn clockwise).
REGULATION
TAPS LUBRIFICATION
Should a tap being blocked, do not
force and ask for Technical
Assistance.
Содержание JZC 63312 A
Страница 12: ...12 KULLANIM JZC 96342 B JZC 96324 A JZC 96342 A JZC 63312 A JZC 64322 A JZC 94313 A JZC 95314 A...
Страница 34: ...34 MONTAJ Ba lant emas 3 4 elemanl modeller i in s tma ye il sar mavi kahverengi gri siyah L3 KULLANMAYIN...
Страница 42: ...42 DESCRIPTION OF HOBS JZC 96342 B JZC 96324 A JZC 96342 A JZC 63312 A JZC 64322 A JZC 94313 A JZC 95314 A...
Страница 72: ...72 JZC 63312 ABN JZC 64322 ABN JZC 94313 ABN JZC 95314 ABN DESCRIEREA PLITELOR DE GATIT...
Страница 102: ...102 POPIS VARN CH DESEK JZC 96342 B JZC 96324 A JZC 96342 A JZC 63312 A JZC 64322 A JZC 94313 A JZC 95314 A...
Страница 132: ...132 JZC 96342 B JZC 96324 A JZC 96342 A JZC 63312 A JZC 64322 A JZC 94313 A JZC 95314 A POPIS VARN CH DOSIEK...
Страница 160: ...Cod 04089E3 25 09 2020 Rev 00...