36
CONVERSIONS
BURNERS
GAS
NORMAL
PRESSURE
mbar
NORMAL
RATE
INJECTOR
DIAMETER
1/100 mm
NOMINAL HEAT
INPUT (W)
N°
DESCRIPTION
gr/h
l/h
Min.
Max.
EEgas burner*
1
ULTRA RAPID
(Version 3.5 kW)
G30 - BUTAN
G31 - PROPAN
G20 - NATURAL
30
30
20
254
250
333
96 S4
96 S4
145 H3
1800
1800
1800
3500
3500
3500
59,4 %
2
RAPID
G30 - BUTAN
G31 - PROPAN
G20 - NATURAL
30
30
20
204
200
267
83
83
117 S
900
900
900
2800
2800
2800
62,5 %
3
SEMIRAPID
REDUCED
G30 - BUTAN
G31 - PROPAN
G20 - NATURAL
30
30
20
102
100
133
60
60
88 Z
550
550
550
1400
1400
1400
64,7 %
4
SEMIRAPID
G30 - BUTAN
G31 - PROPAN
G20 - NATURAL
30
30
20
127
125
167
65
65
97 Z
550
550
550
1750
1750
1750
61,1 %
5
AUXILIARY
G30 - BUTAN
G31 - PROPAN
G20 - NATURAL
30
30
20
73
71
95
50
50
72 X
450
450
450
1000
1000
1000
N.A.
TABLE
*In accordance with Regulation No. 66/2014 EU measures for the implementation of Directive 2009/125/EC,
the performance (EEgas burner) was calculated according to EN 30-2-1 last review with the G20.
10) REPLACING THE INJECTORS
The burners can be adapted to different types of
gas by mounting injectors suited to the type of gas
in question. To do this, first remove the burner tops
using a wrench. Now unscrew injector(see fig. 17-
17/A) and fit a injector corresponding to the
utilized type of gas in its place.
It is advisable to strongly tighten the injector in
place.
After the injectors have been replaced, the
burners must be regulated as explained in
paragraphs 9. The technician must reset any
seals on the regulating or pre-regulating
devices.
The envelope with the injectors and the labels
can be included in the kit, or at disposal to the
authorized customer Service Centre.
For the sake of convenience, the nominal rate
table also lists the heat inputs of the burners, the
diameter of the injectors and the working
pressures of the various types of gas.