Technical information 

11

10

Before calling the repairs service, make the
following checks:

If something doesn’t work

Fault

Possible causeSolution

The hood doesn’t work

Mains cable not connected

Connect mains cable

Power not reaching plug

Check/repair mains supply

Hood not extracting 

sufficiently or vibrating

Filter saturated with grease

Clean or replace filter

Obstruction in venting duct

Remove obstruction

Inadequate venting duct

Contact installer and follow

the instructions in this manual

Lights do not work

Bulbs blown

Replace bulbs

Bulbs loose

Tighten up bulbs

MOD.
TYP.

ELECT.

220...230 V ~ 

50 Hz

190 W

Made in European Community- C.I.F.: A-39004932

CS-6000

S-622325

Nº. de fabric.
Fabrík.-Nr.
Serial Nº

89-555551

POTENCIA NOM. LÁMPARAS
NENLEISTUNG GLÜHLAMPEN
LAMPS RATE
PUISSANCE LAMPES

2 X 40 W

POTENCIA NOM. DAS LAMPADAS

Dimensions (mm)

Voltage

Frequency

Maximum load

600 (900) x 500 x 150
Width x length x height

SEE CHARACTERISTICS LABEL

Содержание CS-6000

Страница 1: ...nd maintenance recommendations Cooker Hoods CS 6000Using this instruction book Montageanleitung und Pflegehinweise Dunstabzugshauben CS 6000 Instructions d installation et recommandations d entretien Hottes aspirantes CS 6000 ...

Страница 2: ... or is cut or if the appliance shows visible signs of wear on the part where the controls are found If the hood stops working or works abnormally disconnect it from the mains unplug and inform the Technical Assistance Service Do not leave gas burners turned on under the hood without their being covered by a recipient such as a pot or pan Do not allow grease to build up on any part of the hood espe...

Страница 3: ...These hoods are fitted with A Light switch B Sliding three speed motor control switch C Operation indicator light D Controllable visor that enables better smoke collection gases E Filter body and supports F Filter support closures G Light bulb illumination over the coo king area and set behind a light diffu ser K Easily extractable filter fitted in the lower part of the suction surface optional H ...

Страница 4: ...t to indicate operation of any of them 0 Off position 1 First speed 2 Second speed 3 Third speed This is independent of the motor This enables the lights to be used regardless of whether the hood is in use Off On Motors Switch on the extractor fan a few minutes before you start to cook 3 to 5 minutes in order to ensure that a steady air flow has been establis hed before cooking fumes appear Allow ...

Страница 5: ...lic scourers Do not use abrasive products that may damage the metallic surface Do not scratch with hard objects such as knives scissors etc The activated carbon filter cannot be washed or regenerated Once it has become soiled obstructed it must be replaced A Wait for the motor to cool before carrying out this operation Remove the screw that holds the grill to the support Turn the grill in an antic...

Страница 6: ...truction in venting duct Remove obstruction Inadequate venting duct Contact installer and follow the instructions in this manual Lights do not work Bulbs blown Replace bulbs Bulbs loose Tighten up bulbs MOD TYP ELECT 220 230 V 50 Hz 190 W Made in European Community C I F A 39004932 CS 6000 S 622325 Nº de fabric Fabrík Nr Serial Nº 89 555551 POTENCIA NOM LÁMPARAS NENLEISTUNG GLÜHLAMPEN LAMPS RATE P...

Страница 7: ...ht angles 90º If the hood is supplied without a plug for mains connection or if this is replaced it must be disconnected from the mains by means of an omnipolar cut off switch with a minimum contact separation of 3 mm at all the poles incorporated into the fixed installation The installation connection should be carried out using flexible wire It must not be done using a rigid tube The hood should...

Страница 8: ...ike this and cutting off any remaining burrs 15 Replacing the mains cable 14 Extraction through the upper part A Re circulation through active carbon The system requires an outlet conduit The gas extraction lever should be set in the position E situated in the casing An outlet tube non return is fitted checking to ensure that the other outlets are duly cove red Place the lever situated in the casi...