background image

 

During installation, structures, coverings, beams, 
etc.,  must  be  protected  from  combustible  or 
flammable  material  and  which  are  exposed  to 
excessive  heat  from  both  the  stove  and  the 
chimney,  particularly  when  crossing  partitions 
and  false  ceilings.  In  these  cases,  appropriate 
thermal  insulation  should  be  used,  namely 
vermiculite. 

Check  point  13-  Models  and  technical 
characteristicsf
or more information. 

 

Figure 3- Minimum dimensions to respect the envelope and 

minimum height of the chimney 

The  manufacturer  will  not  be  responsible  for 
changes  in  the  properties  of  the  materials 
surrounding the stove and chimney. 

 

7.4.  Air intake 

 

The heat generated by the stove results from the 
heat  produced  by  the  chemical  reaction  of 
combustion  of  the  pellets  in  the  combustion 
chamber. 

For  this  combustion  to  occur  under  the  best 
conditions,  it  is  necessary  to  safeguard  the 
correct  amount  of  oxidizing  agent  (oxygen 
present in the air). 

During operation, the stove absorbs an amount of 
air  from  the  place  where  it  is  located,  which 
enters  the  combustion  chamber  through  an  air 
inlet located at the back of the stove, which can 
be channeled to the outside. 

You must not use bends or tubes with a section 
smaller  than  60mm,  nor  a  maximum  length 
greater than 800mm. 

You must also safeguard that this admission will 
never be obstructed from the outside and that it 
is at least 20 cm from the ground. 

Outside,  you  should  put  protection  against  rain 
and wind. 

Safeguard  the  requirements  and  relative  to 
ventilation and air supply referred to in point 7.2- 
Installation constraints. 

In the figure below you will find several examples 
that  will  help  you  to  verify  the  stability  and 
correction of the flame. 

 

 

 

 

Correct combustion 

Bright flame with light 
yellow color and minimum 
amount of pellets in the 
brazier 

 

 

 

Incorrect combustion 

Flame too bright too 
much oxidizer. 

Too many glowing pellets 
come out of the brazier. 

Correct the amount of air 
(from 0 to +5) correct the 
feeder if necessary (from 
0 to -5). 

If not, contact technical 
support. 

 

Incorrect combustion 

Flame too dark yellow, 
wobbling, with too many 
unburned pellets in the 
brazier. 

Check that the door or 
ash bin is closed. 

Otherwise, correct the 
amount of air (from 0 to 
+5) correct the feeder if 
necessary (from 0 to -5). 

If not, contact technical 
support. 

Содержание EBONY

Страница 1: ...TEK Biomasse 2022 NG01 K100 EN220831 EBONY SLIM Pellet stove Instruction Manual...

Страница 2: ...2...

Страница 3: ...ation 12 7 9 1 Calculation of thermal power and average hourly consumption 12 8 Use of the stove 12 8 1 Useful information 12 8 2 Lighting 12 8 3 Stop 12 8 4 Unplug the device from the mains 13 8 5 K1...

Страница 4: ...nd health and domestic animals 1 3 Packaging of documentation This manual as well as any other applicable documentation must be stored diligently so that it is available at all times In case of moving...

Страница 5: ...ctive or out of calibration On water models the installer must inform the user of the following In case of water leaks it is necessary to turn off the water supply and immediately notify technical sup...

Страница 6: ...resulting from improper use or negligence lack of maintenance installation in violation of current regulations and laws Use of poor quality pellets or any other similar product in disregard of the pr...

Страница 7: ...is the only fuel indicated for this equipment Yield and power vary depending on the quality of pellets used For correct operation you must use pellets according to the characteristics below Technical...

Страница 8: ...comply with some essential rules Improper installation will compromise the safety and proper functioning of the stove When installing the equipment all national and local regulations as well as Europe...

Страница 9: ...n chamber through an air inlet located at the back of the stove which can be channeled to the outside You must not use bends or tubes with a section smaller than 60mm nor a maximum length greater than...

Страница 10: ...erted installation male downwards to prevent condensation from flowing out of the chimney For chimneys over 5 meters high their section must change to a diameter of 100 mm after 5 meters The dimension...

Страница 11: ...out by qualified personnel according to EN 10683 Ensure that the electrical installation is earthed With the switch off connect the cable to the wall socket and plug Figure 7 Turn on the switch to el...

Страница 12: ...ned off The ash compartment must not be opened while the stove is operating Wait for it to stop and cool down completely to clean the ash Simultaneous use with other ventilation systems see point 7 2...

Страница 13: ...Panel shows Time and date chrono activation combustion heating power operating mode room temperature and required main temperature keys Occupation P1 Exit Menu Submenu P2 Ignition Extinguishing press...

Страница 14: ...maximum value of the temperature scale probe Open door You must close the door door Delay in stopping the equipment The equipment was turned off when it was on Wait for this operation to complete OFF...

Страница 15: ...displayed a automatic combustion m manual combustion and the operating power of the system Heating By entering this menu you can change the heating power You can configure it in automatic or manual mo...

Страница 16: ...s are the same for every day of the week Weekend Select between Monday to Friday and Saturday to Sunday times and set the ignition and extinguishing time Refill This menu allows you to activate the fu...

Страница 17: ...n level to automatic Keyboard Menu Shine Allows you to adjust the brightness of the panel Contrast Allows you to adjust the panel contrast My Light Allows you to adjust the minimum brightness of the p...

Страница 18: ...ty of the pellets used Figure 9 Brazier Put the brazier back in place ensuring the perfect alignment of the resistance hole with the respective resistance Incorrect alignment can cause ignition failur...

Страница 19: ...d between the central fins of the grid as shown in the picture below Open the combustion chamber door remove the brazier and vacuum the ash using an ash vacuum Remove the ash drawer and open the lower...

Страница 20: ...back panel just remove the screws Removing the alter panels implies loosening 2 screws as shown in the picture Pull the panel upwards by detaching them as shown in the image Loosen the screw as marked...

Страница 21: ...not to damage the blades 9 3 1 Chimney cleaning Chimney cleaning should be carried out at least twice a year at the beginning and middle of the winter season or when necessary This cleaning must be ca...

Страница 22: ...ucture and or scrape the paint 9 5 End of season maintenance At the end of the heating season you must have your stove completely serviced by a specialized technician This maintenance is intended to e...

Страница 23: ...ature lack of fuel Occurs if the smoke temperature drops below the minimum value set for extinguishing Lack of fuel Low calorific fuel Too down correction of pellet recipe Refill hopper Check fuel qua...

Страница 24: ...n vessel is confirmed Er11 Internal clock error Incorrect day and time due to prolonged absence of power supply The boiler has been disconnected from power for a long time and the internal battery has...

Страница 25: ...eference value not reached Possible obstruction of the chimney or air intake Open ash door or drawer Clean the chimney Check door seal and ash drawer Er42 Air flow mass sensor During the Check Phase U...

Страница 26: ...26 11 ELECTRICAL SCHEME...

Страница 27: ...27 12 DIMENSIONS AND CONNECTIONS EBONY model...

Страница 28: ...28 SLIM Model...

Страница 29: ...7 9 4 8 7 9 4 8 Air Pellet consumption kg h 1 91 0 99 1 91 0 99 Autonomy H 6 80 12 10 6 80 12 10 Performance 86 85 86 85 CO to 13 O 2 ppm 0 01 0 01 0 01 0 01 Mass flow of smoke g s 7 52 6 99 7 52 6 99...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...and Factory 1 Factory 2 Estrada dos Guilhermes 27 Moinho de Vento 1 E 2405 012 Maceira LRA 2405 008 Maceira LRA Portugal Portugal Phone 351 244 770 240 comercial grupovm pt www tekbiomasse com Authori...

Отзывы: