TEK Biomasse EBONY Скачать руководство пользователя страница 4

 

1. 

G

ENERAL 

C

ONSIDERATIONS

 

 

TEK Biomasse 

® 

is a registered trademark, whose 

air  conditioning  equipment  is  manufactured  by 
Vitor Monteiro Lda., and tested in accordance with 
European reference safety standards. 

 

1.1.  Symbology 

 

The  following  graphic  symbols  are  used  in  this 
manual: 

 

- Tips and useful information, 

 

-  Danger,  important  information  to  avoid 

accidents. 

 

Attention:  the  symbols  indicate  important 
information  in  order  to  make  the  manual  more 
lucid. However, this does not relieve the user of 
the obligation to comply with  requirements that 
are not marked with a graphic symbol. 

This manual is divided into two parts: one for the 
user and one for the installer. Both parts contain 
important  and  significant  information  for  safety 
issues, therefore, the user should read both parts 
of  the  manual.  We  are  not  responsible  for  any 
damage  caused  by  failure  to  follow  these 
instructions. 

 

1.2.  Use 

 

This equipment is a stove intended for domestic 
heating and is reserved for indoor installation. It 
must not be operated by anyone unfamiliar with 
this manual as well as by children, the elderly and 
others  whose  physical,  mental  and  intellectual 
capacities are impaired. 

Failure to observe these rules can cause property 
damage,  threat  to  human  life  and  health  and 
domestic animals. 

 

 

1.3.  Packaging of documentation 

 

This  manual,  as  well  as  any  other  applicable 
documentation, must be stored diligently so that 
it is available at all times. In case of moving or 
selling  the  equipment,  the  documentation  must 
be  attached  and  forwarded  to  the  new 
user/owner. 

 

2. 

S

ECURITY WARNINGS

 

 

The instructions contained in this manual must be 
followed,  both  by  the  Technician  (Installer, 
Maintenance)  and  by  the  User.  Some  of  the 
warnings,  if  not  followed,  void  the  warranty 
contract. 

 

2.1.  Installer 

Technician 

and 

Maintenance Manager 

 

The  installation  of  the  stove  is  exclusively 
reserved for specialized technicians. 

The  responsibility  for  installing  the  equipment 
cannot  be  considered  the  responsibility  of  Vitor 
Monteiro, Lda. 

 

In case of need for works at the installation site 
of  the  stove,  these  are  the  responsibility  of  the 
user and whose expense falls on the same. The 
works,  before  being  carried  out,  must  be 
approved by the user. 

 

The  technical  responsibility  for  the  installation 
rests with the installer, who is asked to carry out 
the chimney and air intake checks and carry out 
the proposed installation solutions correctly. 

 

Installation  of  the  equipment  must  comply  with 
all national and European regulations, standards 
and laws. 

The  equipment  must  be  installed  on  a  surface 
capable of supporting its weight. 

 

Confirm  that  the  chimney  design  and  air  intake 
are in accordance with the installed equipment. 

Содержание EBONY

Страница 1: ...TEK Biomasse 2022 NG01 K100 EN220831 EBONY SLIM Pellet stove Instruction Manual...

Страница 2: ...2...

Страница 3: ...ation 12 7 9 1 Calculation of thermal power and average hourly consumption 12 8 Use of the stove 12 8 1 Useful information 12 8 2 Lighting 12 8 3 Stop 12 8 4 Unplug the device from the mains 13 8 5 K1...

Страница 4: ...nd health and domestic animals 1 3 Packaging of documentation This manual as well as any other applicable documentation must be stored diligently so that it is available at all times In case of moving...

Страница 5: ...ctive or out of calibration On water models the installer must inform the user of the following In case of water leaks it is necessary to turn off the water supply and immediately notify technical sup...

Страница 6: ...resulting from improper use or negligence lack of maintenance installation in violation of current regulations and laws Use of poor quality pellets or any other similar product in disregard of the pr...

Страница 7: ...is the only fuel indicated for this equipment Yield and power vary depending on the quality of pellets used For correct operation you must use pellets according to the characteristics below Technical...

Страница 8: ...comply with some essential rules Improper installation will compromise the safety and proper functioning of the stove When installing the equipment all national and local regulations as well as Europe...

Страница 9: ...n chamber through an air inlet located at the back of the stove which can be channeled to the outside You must not use bends or tubes with a section smaller than 60mm nor a maximum length greater than...

Страница 10: ...erted installation male downwards to prevent condensation from flowing out of the chimney For chimneys over 5 meters high their section must change to a diameter of 100 mm after 5 meters The dimension...

Страница 11: ...out by qualified personnel according to EN 10683 Ensure that the electrical installation is earthed With the switch off connect the cable to the wall socket and plug Figure 7 Turn on the switch to el...

Страница 12: ...ned off The ash compartment must not be opened while the stove is operating Wait for it to stop and cool down completely to clean the ash Simultaneous use with other ventilation systems see point 7 2...

Страница 13: ...Panel shows Time and date chrono activation combustion heating power operating mode room temperature and required main temperature keys Occupation P1 Exit Menu Submenu P2 Ignition Extinguishing press...

Страница 14: ...maximum value of the temperature scale probe Open door You must close the door door Delay in stopping the equipment The equipment was turned off when it was on Wait for this operation to complete OFF...

Страница 15: ...displayed a automatic combustion m manual combustion and the operating power of the system Heating By entering this menu you can change the heating power You can configure it in automatic or manual mo...

Страница 16: ...s are the same for every day of the week Weekend Select between Monday to Friday and Saturday to Sunday times and set the ignition and extinguishing time Refill This menu allows you to activate the fu...

Страница 17: ...n level to automatic Keyboard Menu Shine Allows you to adjust the brightness of the panel Contrast Allows you to adjust the panel contrast My Light Allows you to adjust the minimum brightness of the p...

Страница 18: ...ty of the pellets used Figure 9 Brazier Put the brazier back in place ensuring the perfect alignment of the resistance hole with the respective resistance Incorrect alignment can cause ignition failur...

Страница 19: ...d between the central fins of the grid as shown in the picture below Open the combustion chamber door remove the brazier and vacuum the ash using an ash vacuum Remove the ash drawer and open the lower...

Страница 20: ...back panel just remove the screws Removing the alter panels implies loosening 2 screws as shown in the picture Pull the panel upwards by detaching them as shown in the image Loosen the screw as marked...

Страница 21: ...not to damage the blades 9 3 1 Chimney cleaning Chimney cleaning should be carried out at least twice a year at the beginning and middle of the winter season or when necessary This cleaning must be ca...

Страница 22: ...ucture and or scrape the paint 9 5 End of season maintenance At the end of the heating season you must have your stove completely serviced by a specialized technician This maintenance is intended to e...

Страница 23: ...ature lack of fuel Occurs if the smoke temperature drops below the minimum value set for extinguishing Lack of fuel Low calorific fuel Too down correction of pellet recipe Refill hopper Check fuel qua...

Страница 24: ...n vessel is confirmed Er11 Internal clock error Incorrect day and time due to prolonged absence of power supply The boiler has been disconnected from power for a long time and the internal battery has...

Страница 25: ...eference value not reached Possible obstruction of the chimney or air intake Open ash door or drawer Clean the chimney Check door seal and ash drawer Er42 Air flow mass sensor During the Check Phase U...

Страница 26: ...26 11 ELECTRICAL SCHEME...

Страница 27: ...27 12 DIMENSIONS AND CONNECTIONS EBONY model...

Страница 28: ...28 SLIM Model...

Страница 29: ...7 9 4 8 7 9 4 8 Air Pellet consumption kg h 1 91 0 99 1 91 0 99 Autonomy H 6 80 12 10 6 80 12 10 Performance 86 85 86 85 CO to 13 O 2 ppm 0 01 0 01 0 01 0 01 Mass flow of smoke g s 7 52 6 99 7 52 6 99...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...and Factory 1 Factory 2 Estrada dos Guilhermes 27 Moinho de Vento 1 E 2405 012 Maceira LRA 2405 008 Maceira LRA Portugal Portugal Phone 351 244 770 240 comercial grupovm pt www tekbiomasse com Authori...

Отзывы: