![TEK Biomasse EBONY Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/tek-biomasse/ebony/ebony_instruction-manual_1075563022.webp)
22
Check the condition of the door and glass sealing
gasket. A seal in poor condition causes poor and
incorrect combustion with a consequent reduction
in efficiency.
Replace the packing whenever it does not
guarantee correct tightness.
Carry out the same check for the ash drawer
packing.
9.4. Exterior cleaning
Clean with a dry, non-abrasive cloth.
Do not use water or detergents during the
cleaning process as if it comes into contact with
the metallic structure (iron, cast iron, sheets) it
can cause corrosion of the structure and/or
scrape the paint.
9.5. End of season maintenance
At the end of the heating season, you must have
your stove completely serviced by a specialized
technician.
This maintenance is intended to ensure the
operability of your equipment and ensure the
perfect functioning of all its components.
9.6. Control
and
maintenance
program
Dai
ly
We
ekl
y
Mo
n
th
ly
6 mon
th
s
Yearly
U
se
r
T
ec
h
n
ic
ian
Brazier
X
X
Cleaning the
exchanger
(activate the
mechanism on the
grid)
X
X
Ash compartment
X
X
Glass
X
X
Ignition resistance
tube cleaning
X
X
Turn the
turbulators to
clean the
exchanger (water
version)
X
Stove structure
X
X
Smoke collector
X
X
Door trim and
brazier
X
Chimney flue
X
X
Fans
X
General check of
the smoke circuit
X
Содержание EBONY
Страница 1: ...TEK Biomasse 2022 NG01 K100 EN220831 EBONY SLIM Pellet stove Instruction Manual...
Страница 2: ...2...
Страница 26: ...26 11 ELECTRICAL SCHEME...
Страница 27: ...27 12 DIMENSIONS AND CONNECTIONS EBONY model...
Страница 28: ...28 SLIM Model...
Страница 30: ...30...
Страница 31: ...31...