![Tehnologistic Train-O-Matic Lokommander II Next18 ECU Скачать руководство пользователя страница 157](http://html1.mh-extra.com/html/tehnologistic/train-o-matic-lokommander-ii-next18-ecu/train-o-matic-lokommander-ii-next18-ecu_user-manual_1075475157.webp)
Lokommander II Next18 ECU
User Manual firmware 5.10.306
Version 0.5.07
Page 35 of 118
13.
Function outputs
Function outputs can command different loads such as LEDs, bulbs, smoke generator, electromagnetic
couplers, etc. Lokommander II decoders have 2 kinds of outputs: power outputs and logic outputs.
-
The power outputs have a transistor that connects the output to the ground (-) when the output is
enabled. The loads will be connected between the power output and V+ ().
-
The logic outputs supply a voltage of about + 5V when enabled, otherwise they are connected to the
ground. The logic outputs cannot exceed the maximum current of 5mA, otherwise the decoder can
get defective. A logic output can be used to command 1-2 LEDs with current limiting resistors, or
via an external transistor to command larger loads. To supplement the number of outputs, the SUSI
interface can be disabled (CV122 Bit0 = 0) and the corresponding pins can be used as 2 logical
outputs. By factory default, they are configured as logical outputs. To use them for the SUSI
interface, bit 0 and 1 of CV122 must be set to 1.
Some decoders have outputs that are not available on the connectors. General description of
Lokommander II decoders and Table 3: Output configuration is showing the available auxiliary outputs
(dotted lines in the photos) that can be used with soldered wires.
Table 3: Output configuration
P
–
Power output; L
–
Logical output; O
–
Optional
output, accessible by soldering an additional wire; S
–
Output shared with SUSI.
Format / Name/
Connector
FL RL
AUX
1 2
3
4
5 6 7 8 9 10
N18
NEXT 18
P
P
P P
L,
S
L,
S
L L