background image

 

 

 

 

7-5 

 

10 TEGAM WAY ● GENEVA, OHIO 44041 ● 440-466-6100 ● FAX 440-466-6110 ● 

[email protected]

 

 

Warranty 

TEGAM, Inc. warrants this product to be free from defects in material and workmanship for a 
period of one (1) year from the date of shipment. During this warranty period, if a product 
proves  to  be  defective,  TEGAM  Inc.,  at  its  option,  will  either  repair  the  defective  product 
without charge for parts and labor, or exchange any product that proves to be defective. 

TEGAM, Inc. warrants the calibration of this product for a period of one (1) year from date of 
shipment. During this period, TEGAM, Inc. will recalibrate any product, which does not conform 
to the published accuracy specifications. 

In  order  to  exercise  this  warranty,  TEGAM,  Inc.,  must  be  notified  of  the  defective  product 
before the expiration of the warranty period. The customer shall be responsible for packaging 
and  shipping  the  product  to  the  designated  TEGAM  service  center  with  shipping  charges 
prepaid. TEGAM Inc. shall pay for the return of the product to the customer if the shipment is 
to a location within the country in which the TEGAM service center is located. The customer 
shall be responsible for paying all shipping, duties, taxes, and additional costs if the product 
is  transported  to  any  other  locations.  Repaired  products  are  warranted  for  the  remaining 
balance of the original warranty, or 90 days, whichever is greater. 

 

Warranty Limitations 

The TEGAM, Inc. warranty does not apply to defects resulting from unauthorized modification 
or  misuse  of  the  product  or  any  part.  This  warranty  does  not  apply  to  fuses,  batteries,  or 
damage to the instrument caused by battery leakage. 

The  foregoing  warranty  of  TEGAM  is  in  lieu  of  all  other  warranties,  expressed  or  implied. 
TEGAM  specifically  disclaims  any  implied  warranties  of  merchantability  or  fitness  for  a 
particular  purpose.  In  no  event will  TEGAM  be  liable  for  special  or  consequential  damages. 
Purchaser’s sole and exclusive remedy in the event any item fails to comply with the foregoing 
express warranty of TEGAM shall be to return the item to TEGAM; shipping charges prepaid 
and at the option of TEGAM obtain a replacement item or a refund of the purchase price. 

 

Statement of Calibration 

This instrument has been inspected and tested in accordance with specifications published by 
TEGAM, Inc. 

TEGAM, Inc. certifies the above listed instrument has been inspected and calibrated and meets 
or  exceeds  all  published  specifications  and  has  been  calibrated  using  standards  whose 
accuracies  are  traceable  to  the  International  System  of  Units  (SI)  through  the  National 
Institute  of  Standards  and  Technology  (NIST)  or  other  recognized  National  Metrology 
Institutes. 

Содержание Advanced Energy GEMINI 5540A

Страница 1: ...I 5540A 10 TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 sales tegam com GEMINI 5540A RF POWER METER Operation Manual rev AA Manual Part Number 5540A 900 Rev AA Published August 2022 Genev...

Страница 2: ...and or technical data is TEGAM proprietary information developed exclusively at private expense Computer software and technical data rights granted to the federal government include only those rights...

Страница 3: ...aximum Rated Power 3 1 4 Operating Instructions 4 2 Warm Up Time 4 2 Instrument Overview 4 2 Instrument Power and Communication 4 2 Digital Display 4 3 Ports and Connectors 4 4 5 GEMINI Tools Applicat...

Страница 4: ...and QDS UL Display 6 Digit Auto Resolution OLED Display Display Resolution Up to 6 digits 2 digits past decimal point Power W 0 01 Frequency MHz 0 01 Power Requirement 5 VDC 500 mA Power Data Connect...

Страница 5: ...A Connector Configurations See Appendix C for connector limits and configurations Transport Case 1500 910 Transport Case USB Cable CA 65 72 USB Type A to Type B Data Transfer and Power Cable 36 Inche...

Страница 6: ...inging the sensor display communication port and measurement circuits together into a single instrument with a compact footprint Other features such as fast response times data collection software ava...

Страница 7: ...dustry frequencies and power levels See Appendix C for more information When measurement requirements change simply select a different calibration option 4 Serial connection via the on board USB Type...

Страница 8: ...meters Failure to follow these precautions may result in death or bodily injury or equipment damage Never apply RF power to an unterminated power meter transmission lines or other feedthrough equipme...

Страница 9: ...applied RF power and frequency The GEMINI RF Power Meter requires a load with VSWR better than 2 0 1 to perform within published specifications Failure to follow these precautions could result in inc...

Страница 10: ...910 Transport Case 5540A 901 GEMINI 5540A RF Power Meter Quick Start Guide Calibration Certificate and Documentation Model Number Configuration Each GEMINI RF Power Meter is configurable with various...

Страница 11: ...to the power flowing in the corresponding direction in the transmission line This measurement data is used to calculate forward and reverse power A third coupler is used to determine the frequency VSW...

Страница 12: ...Once properly acclimated to the laboratory environment and powered on the GEMINI RF Power Meter requires at least 10 minutes to stabilize Instrument Overview Component Description OLED Display Realti...

Страница 13: ...ower Meter and perform automated data collection operations the instrument must be connected to and powered from a USB 2 0 or higher port on a computer or other data collection device Digital Display...

Страница 14: ...sconnect transmission lines or the GEMINI RF Power Meter while RF power is active in the system Failure to follow these precautions may result in death or bodily injury or equipment damage Connection...

Страница 15: ...ically saved in delimited text file format Up to five 5 units may be connected monitored and recorded simultaneously It provides real time data visualization on the connected PC and saves the displaye...

Страница 16: ...he numeric decimal separator should consider selecting the tab or semicolon delimiter options to prevent these import errors Operation The application automatically detects GEMINI RF Power Meters conn...

Страница 17: ...ate of the instrument and the active measurement For troubleshooting or questions about particular measurement results use the Snapshot feature and forward the csv file to TEGAM To take a Snapshot 1 C...

Страница 18: ...h other serial instruments It uses the GET Variable Name command format Variable Names are described in Table 1 below The commands are sent as plain character data to the virtual serial port created w...

Страница 19: ...or response codes 6 2 1 Timing The GEMINI RF Power Meter has no triggers or reading clock and cannot deliver precisely timed readings GET when applied to instrument readings does not trigger a new rea...

Страница 20: ...the display lens Mild non abrasive detergents may be used providing the instrument is then wiped down with a clean damp cloth or towel Functional Verification The Gemini 5500 Series are tested and in...

Страница 21: ...evel outside of calibrated range Check certificate and ensure unit is being operated within calibrated frequency range Unresponsive RF power not applied to 5540A input port Check cables connections an...

Страница 22: ...of the malfunction type of components being tested frequency of the symptoms intermittent or continuous conditions that may cause the symptoms changes to the test setup or operating environment that m...

Страница 23: ...ssing and repair process RMA Instrument Model Serial Number Company Technical Contact Phone Number Additional Contact Info Service Instructions Evaluation Calibration Only Repair Only Repair Calibrati...

Страница 24: ...sported to any other locations Repaired products are warranted for the remaining balance of the original warranty or 90 days whichever is greater Warranty Limitations The TEGAM Inc warranty does not a...

Страница 25: ...HZ POWER LEVELS W FWD REV 5540A CAL 0001 12 89 13 56 14 23 3 5000 3 250 5540A CAL 00025 2 0 30 0 5 250 5 250 5540A CAL 0003 1 8 2 2 2 3 5000 3 250 5540A CAL 0004 57 0 60 0 63 0 3 5000 3 250 5540A CAL...

Страница 26: ...A ii 10 TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 sales tegam com B EXPANDED INSTRUMENT UNCERTAINTIES...

Страница 27: ...iii 10 TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 sales tegam com C CONNECTOR POWER LIMITATIONS BY FREQUENCY Figure 5 Power Limitations by Connector Type kW Power limited by 5540A to 5k...

Страница 28: ...10 TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 sales tegam com TEGAM INC 10 TEGAM WAY GENEVA OHIO 44041 CAGE Code 49374 WEB http www tegam com...

Отзывы: