INITIALISATION BOOM SETUP ERROR WITH 8-OUTPUT DRIVERS
When an 8-output driver system on start-up/initialisation has a missing solenoid in the 8
th
position of a driver, the number of sections on the DynaJet will
not match the associated rate controller causing the 3028 Initialisation error due to the 3022 Boom Setup Error.
This happens when using an 8-output driver and the solenoid in error happens to be sitting in the 8th position. This is part of intended programming in
the drivers where the system checks for the end of the driver by looking solenoid ahead. If the 8th solenoid is missing, then the system thinks there are
only 7 solenoids on that driver.