NT579 

STANDARD 

DIGITAL         
(24 Vdc) 

INSTRUCTION MANUAL 

TECSYSTEM SHANGHAI 

3rd Floor, Block No.5, For-

ward High-tech Industrial 

Park, 

No.33, Fuhua Road,          

Jiading District 

 

SHANGHAI - CHINA

 

 

NT579-NT579 RS485  

 

TECSYSTEM SHANGHAI

 

R.1.4 2015/08/10

Содержание NT579

Страница 1: ...NT579 STANDARD DIGITAL 24 Vdc INSTRUCTION MANUAL TECSYSTEM SHANGHAI 3rd Floor Block No 5 For ward High tech Industrial Park No 33 Fuhua Road Jiading District SHANGHAI CHINA NT579 NT579 RS485 TECSYSTEM SHANGHAI R 1 4 2015 08 10 ...

Страница 2: ...lling 1 FAULT common relay sensor fault monitoring unit working anomaly SUPPLY Rated values 18 36 Vdc COMMUNICATION ON DIGITAL OR AD VERSION RS485 MODBUS RTU INPUTS Figure 2 Page 11 3 3 wire PT100 sensor inputs Removable rear terminals Input channels protected against electromagnetic noises OUTPUTS Figure 2 Page 11 2 relays ALARM TRIP with 6A 250Vac resistive contacts cosΦ 1 1 FAN output at 250Vac...

Страница 3: ...plitude 1 mm from 2Hz to 13 2Hz Acceleration 0 7G from 13 2Hz to 100Hz Seismic test according to IEEE 344 1 987 Cross reference T154 for construc tive analogy DISPLAY AND DATA MANAGEMENT Temperature display C TEMPERATURE Selected channel and programming parameter display CHANNEL MESSAGES 4 LED s to show the display mode SCAN AUTO MAN TMAX 4 LED s to show the state of the alarms relevant to display...

Страница 4: ... terminals with the new ter minals supplied provided that they are of a brand different from the previously mounted ones 4 ELECTRICAL CONNECTIONS FOR ALARMS AND E VENTILATION FIGURE 2 PAGE 19 Carry out the electrical connections on the removable rear terminals after having removed them from the meter All relays switch in OFF as the unit turned off and does not run any tem perature control when you...

Страница 5: ...ng units have the sensor signal linearization with a max error of 1 of full scale value The maximum length of the extension cables with 0 12 mm is 50 m The maximum length of the PT100 cable using wires of 1mm section is 500m 7 TEMPERATURE SENSOR DIAGNOSTIC In case of breaking of a temperature sensor mounted on the machine to protect FAULT relay immediately switches with the relevant indication of ...

Страница 6: ...cts a temperature higher than 1 C com pared to set value as alarm limit after approximately 5 seconds ALARM relay switches together with the turning on of ALARM LED if the channel is selected on the CHANNEL display When the release temperature limit is passed TRIP relay switches together with the turning on of TRIP LED if the channel is selected on the CHANNEL display As soon as the taken temperat...

Страница 7: ... the unit run normally without system errors ECH ERROR Ech means that the statement containing the programming data is corrupted or damaged Pressing Reset will delete the message and loads the default values Alarm 90 C 119 C Trip yes Fan Fan on 70 C 60 c Fan off Fcd no no HFN Adr 1 Par eve Bdr 19 2 4 20 Out scan Reprogram the desired values and ensure that these are stored In case of error Ech per...

Страница 8: ...er the ALARM threshold If there are errors ECH or FCD these are reset in order of priority on the alarm is acknowledged 18 IMPORTANT NOTICE Before carrying out the insulation test on the switchboard where the moni toring unit is mounted you have to disconnect it from the mains in order to avoid serious damages NOTES FOR REMOTE PROGRAMMING Also in the remote programming via ModBus phase you must ta...

Страница 9: ...e data shown in the table at pag 13 and write the parameters with RW note MODBUS MAPPING STRUCTURE NOTES The records modbus are divided into 2 main groups From 1 to 18 are present all the temperatures of each channel The display of data is carried out WORD 2 s complement for the management of the sign The HI byte of WORD represents the sign 00 sign FF sign The LO byte contains the data of temperat...

Страница 10: ...d desired threshold From 1 to 200 C 6 PRG SET FAN YES or NO appears If FAN NO is selected jump to point 14 7 Select desired option Load yes or no 8 PRG SET FAN ON threshold for CH L1 L2 L3 appears 9 load desired threshold FAN turning on FAN turning off 10 PRG SET FAN OFF threshold for CH L1 L2 L3 appears 11 load desired threshold FAN turning off FAN turning on 12 PRG SET display shows HFN Fan cycl...

Страница 11: ...onitoring unit is ac tive just when NT579 is in temperature control working mode in one of the intended modes Scan Auto Man and T Max When other functions such as programming programming display and re lay test are activated the ModBus communication is temporarily deacti vated 15 Load desired value see Page 10 From no excluded function to 30 C sec 16 PRG SET ADR appears Unit Modbus address 17 Load...

Страница 12: ...A RS485 standard which suggests to use a 24AWG duplex cable The duplex cable which connects all the units in RS485 could require the activation of the 120 ohm termination on the last unit of the series Connect the duplex cable paying attention to polarities and lay the network avoiding to make sharp bends or ring windings in order not to modify the line impedance If necessary also the GND terminal...

Страница 13: ... codes 3 10 holding register reading 16 10 multiple register writing If ModBus receives a message and a CRC error is detected no answer is given 30 CODE 3 10 Request Slave address code 3 10 Starting address HI Starting address LO Number of Point HI Number of Point LO Crc LO Crc HI Answer Slave address code 3 10 Byte count Data HI Data LO Crc LO Crc HI ERROR CODES exception code In case of wrong re...

Страница 14: ...cause useless for calculation PARAMETER DESCRIPTION A 16 bit register AL At low side AH At huigh side i j KWH METERS EXCLUSIVE OR Di Frame data i th of the packet N number of byte of the packet excluded 2 belonging to CRC G Polynomial 1010 0000 0000 0001 shr right shift ALGORITHM 1 0xFFFF A 2 0 i 3 0 j 4 Di AL AL 5 j 1 j 6 shr A 7 if carry then G A A 8 if NOT j 8 then go to 5 9 i 1 i 10 if NOT i N...

Страница 15: ... to 220 R 0 3 2 compl sign 2 compl Ch L1tem perature alarm set point from 1 to 220 RW 0 4 2 compl sign 2 compl Ch L1 tem perature trip set point from 1 to 220 RW 0 5 2 compl sign 2 compl Ch L1 tem perature Fan on set point from 1 to 220 RW 0 6 2 compl sign 2 compl Ch L1 tem perature Fan off set point from 1 to 220 RW 0 7 2 compl sign 2 compl Ch L2 tem perature from 20 to 230 R 0 8 2 compl sign 2 c...

Страница 16: ... 1 to 220 R Fan on set point 0 12 2 compl sign 2 compl Ch L2 tem perature from 1 to 220 R Fan off set point 0 13 2 compl sign 2 compl Ch L3 tem perature from 20 to 230 R 0 14 2 compl sign 2 compl Ch L3 maximum tempera ture from 1 to 220 R 0 15 2 compl sign 2 compl Ch L3 tem perature from 1 to 220 R alarm set point 0 16 2 compl sign 2 compl Ch L3 tem perature from 1 to 220 R trip set point 0 17 2 c...

Страница 17: ...channel L1 Status See CHn status note R 0 43 0 Ch L2 status channel L2 Status See CHn status note R 0 44 0 Ch L3 status channel L3 Status See CHn status note R 0 45 0 Ch L1 story channel L1 Alarm history See CHn story note R 0 46 0 Ch L2 story channel L2 Alarm history See CHn story note R 0 47 0 Ch L3 story channel L3 Alarm history See CHn story note R 0 48 0 HFN setting fan test cycle hours 0 No ...

Страница 18: ...used FAN FCD FOC FCC CH A b c STORY BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Not used TRIP ALARM Not used Not used Not used FOC FCC Address HI 10 Address LO 10 Data HI Data LO Note 1 Note 2 R read W write RW read write 0 51 0 Address Modbus address 1 255 R 0 52 0 Bdr Modbus baud rate 0 2400 Baud R 1 4800 Baud 2 9600 Baud 3 19200 Baud 4 38400 Baud 0 53 0 Parity Modbus parity bit 0 No Parity ...

Страница 19: ... dataplease refer paragraph 8 If this problem should persist please contact TECSYSTEM SH Technical De partment All the Pt100 sensor are in FCC Wrong sensor connections Terminal box connected inside out Check connections and terminal box The temperature of the sensors is un der 15 C All the Pt100 sensor are in FOC Wrong sensor connections Terminal box connected inside out Check connections and term...

Страница 20: ...elay once energised makes evident this anomalous condition for the motor working By activating the FCD function it is possible to have on 54 55 contacts a Fault signal when the temperature registered by a Pt100 increases with a speed higher than n C sec loadable from 1 to 30 Depending on the loaded value you can have a different sensitivity which can be useful for various applications from 1 to 10...

Страница 21: ...IP FAULT FAN REAR PANEL RS485 DIGITAL OUTPUT 50 51 54 55 62 61 60 Gnd 56 57 Relay fan contact ON OFF 1 2 3 CH L1 WHITE 4 5 6 7 8 9 CH L2 CH L3 RED RED 52 53 BE CAREFUL TO CONNECT THE POWER SUPPLY WITH THE RIGHT POLARITY 41 42 NOTE when the unit is powered the fault relay 54 55 opens and it closes again in case of fault condition or no power ...

Страница 22: ...omponents defects The warranty is invalid if the Product proves tampered modified incorrectly connected because voltages outside the limits non compliance with the technical data for use and assembly as described in this instruction manual Any action about warranty is always at our factory in SHANGHAI JIADING CHINA as stated by the General Conditions of Sale Tecsystem SHANGHAI RAEE This SYMBOL sho...

Страница 23: ...23 NT579 NT579 RS485 TECSYSTEM SHANGHAI ...

Страница 24: ...24 NT579 NT579 RS485 TECSYSTEM SHANGHAI ...

Страница 25: ...http www tecsystem asia 系列 NT579 STANDARD DIGITAL 24 Vdc 中国上海市嘉定区复华路33号5幢B区三层 邮编 201818 电话 862139905855 56 57 118 传真 862139905859 NT579 NT579 RS485 智能温控器 使用手册 TECSYSTEM SHANGHAI R 1 2 2015 08 10 ...

Страница 26: ...温报警 跳闸 1 路故障FAULT输出 每个报警继电输出触点容量 5A 250Vac 1路风机启 停无源控制输出 容量为12A 250Vac cos Φ 1 1路RS485数字输出 NT579dig NT579 NT579 RS485 智能温控器 TECSYSTEM SHANGHAI 测试以及性能 按照CE规范的要求进行组装 抗电噪声干扰符合CEI EN 61000 4 4 温控器绝缘强度不低于2 5kVac 变送器和电源之间 变送器和传感器之 间和电源和传感线之间的绝缘强度均为2 5kVac 历时1分钟 精度为 1 分辨率 1 C 操作温度为 20 C 至 60 C 非露点湿度为90 前面板为聚碳酸酯材料 IP54防护等级 2 ...

Страница 27: ...震测试符合IEEE 344 1 987标准要求 显示及数据管理 温度显示 单位 C 所选择通道和编程显示 通道类别和信息 4个LED用于显示当前温控器的显示模式 自动循环 最高温度 手动设置和黑盒子四种显示模式 4个LED显示对应的输出报警状态 高温 跳闸 故障和风机启动 1个LED用于RS485通讯工作显示 NT579dig 温度监控范围0 C 至200 C 可对通道CHL1 L2 L3进行 高温报警ALARM和跳闸TRIP 两级报警 设定 可自行设定风机启动 停止的温度门槛值 传感器自检功能 Fcc 报警 传感器短路 Foc 报警 传感器开路 数据存储诊断 Ech 通过面板按键方便的进行编程操作 编程错误自动显示 Err 带有清除报警操作面板按键 NT579 NT579 RS485智能温控器 TECSYSTEM SHANGHAI 3 ...

Страница 28: ...由于某种原因 需要更换温控器 用户必须将所有的接线端子 连同温控器一起更换为新的 以防止 原来的接线端子不匹配造成连 接不良 4 有关风机控制与报警输出端子的连接 首先将可拆卸接线端子从设备上拆下 然后在其上进行接线操作 只有当达到设置的温度门槛值时 报警和跳闸输出触点才会发生触发 FAULT 继电触点只在仪表出现故障的情况下触发 例如PT100传感器故 障 数据内存故障 供电电压缺陷 仪表校验故障 当仪表处于编程状态 编程查看模式或继电器测试状态时 所有的输出 继电器均处于关闭状态 仪表无电状态 FAN控制触点可用于变压器冷却风机的启停控制 无源 仅开关量 请断开电源后 进行所有连接 FAULT故障报警继电输出 是针对温度 监控系统本身的故障或环境干扰造成的报警 一定注意不能连接到 变压器的跳闸控制线路上 建议在风机和温控器的连接线路上 根据实际的负载 加装一个电容保 护 4 ...

Страница 29: ...列温控器均采用线性函数信号计量方法 整个检测范围 内 5 温度传感器连接 每个Pt 100温度传感器都具有一条白色线和两条红色线 符合CEI 75 8标 准 第23页的图2显示了具体的接线位置 TECSYSTEM S r l 公司按照CEI标准的规定设计了一种专用信号传输电 缆 可以防止各种干扰 其型号为 CT ES 7 温度传感器诊断 一旦安装在被保护设备上的温度传感器发生损坏 故障 FAULT 继电 器则会立即闭合 并且在显示屏上显示相关故障通道 Fcc为传感器短路或者检测到温度低于 15 C Foc为传感器开路 Fcd 异常温升报警功能 请看第22页的注解 如果要清除错误信息和故障 FAULT 报警状态进行重新设置之前 用 户必须确保故障传感器已经修复或者更换 如果发生FCD FCC或Foc 报警 用户无需过分紧张这个不会造成对变压器的误动作 ...

Страница 30: ...时间 000 FCD no Adr 1 Par eve Bdr 19 2 4 20输 出为SCAN模式 通过按下RESET键来消除Ech报警显示 并且运行编程以输入所需值 设定好之后 按下TEST键进行程序测试 如果Ech报警仍然出现 则说 明仪表硬件故障 需将仪表返回TECSYSTEM公司或当地代理进行维 修 9 测量线路自检 如果温控器内部测量线路损坏或突发问题 仪表通电后将会显示 CAL字符 并输出Fault故障报警 可通过PRESS按键消除此报警 此时请将此仪表返回TECSYSTEM公司检修 10 温度诊断 ALARM 高温报警触发只有在温度传感器所探测到温度高出设定报警温 度1 C或以上 并持续5秒钟或以上的情况下 才会触发报警同时亮 起通道LED 告警灯 CHn TRIP 跳闸报警触发只有在温度传感器所探测到温度高出设定跳闸报警 温度 才会触发报警同时亮起通道LED 告警灯 C...

Страница 31: ...度最高的通道 MAN 通过 键手动选择显示通道 T MAX 俗称 黑盒子 功能 可以用 按键查看各通道曾经出现 过的历史最高温报警状态 用 按键来选择通道 注意 按RESET键该历史记录将被删除 在SCAN 和 MAN 模式时注意 在这两种模式下 有可能会从CPU读到如下信息 1 Run Cpu 表示温控器正常运转 2 Ech Err 存储器损坏或错误 3 CAL Err 温控器的测量线路损坏 4 Pt Err 一条或多条Pt100 传感器工作不正常 14 查看程序设定值 如果要查看已编程门槛值 则短按PRG键 这时 Vis 显示将会出现2 秒钟以后 便开始进入编程查看模式 每按一次PRG按键 相关功 能设定门槛值将顺序显示 如需终止查看模式 则按下ENT键 或当键盘一分钟无任何操作后 自 动终止查看模式 15 编程模式进入 如果进入编程操作进行数据设定 则持续按PRG键约5秒 直到 PR...

Страница 32: ...按TEST键 这时所有的显示灯将会被亮起2 17 取消报警触点的功能输出 如果您取消报警触点的功能输出 请按下RESET键 触点将自行断开 但LED告警灯仍将继续闪烁 只有当相应的温度回降到设定的报警温 度以下时 LED报警指示灯自动熄灭 18 重要提示 当用户对变压器进行耐压或绝缘测试时 必须断开温控器的各种连接 如果其中一个LED灯不工作 需将仪表返回TECSYSTEM公司或当地代 理公司进行维修 LED灯用户无法进行现场维修更换 需要整机返回工 厂维修 19 面板信息 图示1 报警信息 温度及报警 信息显示屏 显示模式 8 操作按键 显示屏 操作按键 ...

Страница 33: ...功能键 显示通道CH L1 L2 L3的挑闸TRIP门限值 5 按此上下选择按键用于调整 所需门槛值 可设定范围从1 200 C 6 PRG SET 续按此功能键 显示FAN YES 或NO 字符 7 续按此功能键可选择YES或 NO状态 如果选择NO 请转至第14步 骤操作 8 PRG SET 续按此功能键 显示出厂时 设定的启动风机门槛值 9 按此上下选择按键用于调整 风机启动所需温度值 启动温度必须大于下边设定的 风机关闭温度 10 PRG SET 续按此功能按键 显示风机 关闭温度值 11 按此上下选择按键用于调整 风机停止所需温度门槛值 停止温度必须小于上边设定的 风机启动温度 12 PRG SET 续按此功能按键 显示HFn 字样 进入风机自检设定模 每 n 小时风机自检运行5分 钟 13 续按此功能按键 设置风机 自检运行的间隔时间 每 小时 no表示禁止该自检功能 9 ...

Страница 34: ...ET 续按此功能按键 显示ADR 温控器Modbus通讯地址 16 21步只是针对带通讯功能 22 PRG SET 按此键 END字符显示 23 ENT 按此键 保存设置 退出编程 如此时出现Err字符 代表前面 的编程错误 重新返回第2步 操作 1 如果按ENT按键结束编程后 屏幕显示ALL Err字符 则表示编程 中跳闸报警温度低于高温报警的温度 请去相关步骤做修改 内置MODBUS模块介绍 这种内置MODBUS扩充模块内置在NT579温控中 它可以通过 ModBus RTU协议向RS485网络传输数据 10 17 续按此功能按键 设定地址 从1到255 18 PRG SET 续按此功能按键 显示BDR字符 通讯的波特率 19 设定波特率 从2 4到38 4 20 PRG SET 按此键 显示PAR字符 Modbus 字符的奇偶校验 21 按此键设定 可选择No even odd ...

Страница 35: ...网络数据传输 内置ModBus功能 使NT579温控器通过Modbus RTU协议连接到 RS485 Modbus通讯网路上 用户可以读取和写入第17 18 19 20项中 Modbus通讯报文表中的相关内容和数据 温控器始终处于从属通讯模 RS485 Modbus接线 为了所使用的信号电缆能够确保网络的正常工作 我们建议按EIA RS485标准所建议使用的24AWG回线 用于连接所有温控器于RS485通讯的线缆 在最后一个温控器的连 接末端 最好激活120欧姆终止端 RS485通讯连接线 接线时须考虑极性并平放 以避免产生锐弯和 环状绕圈 如有必要 也可以使用GND端子接地 帧数据 异步传输帧由1个起始位 8个数据位和1个奇偶性校验位 偶数或奇 数 如奇偶性校验位已加载 和1个停止位构成 适合的特速率 2400 4800 9600 19200和38400 如没有特别规定 则字长 数据 为...

Страница 36: ...地址 1 比特 功能编码 1 比特 数据 变量 取决于功能编码 循环冗余校验 2 比特 功能编码 ModBus 模块支持下列功能编码 3 10 保持寄存器读取 16 10 复式寄存器写入 如果ModBus收到一个信息并且检测到一个循环冗余校验错误 则不 应答 3 10 编码 请求 从属地址 3 10 编码 HI启动地址 LO启动地址 HI点数和LO Crc LO和Crc HI点数 应答 从属地址 3 10 编码 字节计数 HI数据 LO数据 Crc LO 和Crc HI NT579 NT579 RS485 智能温控器 TECSYSTEM SHANGHAI 12 ...

Страница 37: ...i N 属于CRC的紫字符信息包中的 比特数 不包括2 G 多项式 1010 0000 0000 0001 Shr 右移位 错误码 异常码 如果遇到错误请求 MODBus将做出答复并提供下列修改的编码和编 码错误 1 无支持功能编码 2 错误数据地址 3 错误数据 比如长度 轮询频率 回答一个呼叫时限不得超过1秒 因此我们建议在较低的持续时间时 不要使用轮询频率 CRC运算 对每个数据传输 本协议包括2个比特CRC 16 运算采用特征多项式 11000000000000101B 并且其结果为处于信息包末端的 hung 多项式 采用倒序方式并且压缩最重要的比特 因为其在运算中不是很有用 13 ...

Страница 38: ...to 5 9 i 1 i 10 if NOT i N then go to 3 11 A in CRC result is in the order L H 16 10 编码 请求 从属地址 16 10 编码 HI启动地址 LO启动地址 HI点数 LO 点数 字节计数 HI数据 LO数据 Crc LO和Crc HI 应答 从属地址 16 10 编码 HI启动地址 LO启动地址 HI点数和LO Crc LO和Crc HI点数 报警门槛值 寄存器3 4 5 6 仅仅被写入通道1 并自动复制到第2和第3 NT579 NT579 RS485 智能温控器 TECSYSTEM SHANGHAI 14 ...

Страница 39: ...您错误地设置了这些门限 则NT579温控器 将不能继续数据编 程和储存 接下来读数时 读到的数据是原来编程所对应的数据 当发送了一个写入请求后 监视器会用大约1秒钟的时间将它储存在 可擦除只读储器中 然后需要几秒钟重启 在储存阶段 ModBus将不再 处理其它的请求 如果当前写入请求成功 温控器将自动复位并进入下一步新的编程 数据设定 负的温度数值将会以2个字节加以显示负数 FF代表负数 各个通道的记录可通过编码3查看 从地址1到地址18 Modbus报 文表中 工作注意事项 选择Modbus inside 功能 NT579温控器可以通过MODBUS RTU协议 与RS485网络连接 通过读写注解 读取和写入报文表中相应的参数 15 ...

Страница 40: ...地址1到地址18 是所有通道的关于温度的内容信息 数据显示中2个高位字符 是用于正 负区分 管理的 地址的高字节 00 代表 FF代表 地址的低字节代表温度数值 从地址41到53是所有关于报警 控制信息等方面的内容 在这些里面 寄存器中就不会出现正负的情况了 寄存器地址高字节数值永远是0 地址的低字节是数据 如果目录中的操作形式不符合上述两部分内容的形式 控制系统中就 会出现异常乱码 NT579 NT579 RS485 智能温控器 TECSYSTEM SHANGHAI 16 ...

Страница 41: ...emperature alarm set point from 1 to 220 RW 0 4 2 compl sign 2 compl Ch L1 temperature trip set point from 1 to 220 RW 0 5 2 compl sign 2 compl Ch L1 temperature Fan on set point from 1 to 220 RW 0 6 2 compl sign 2 compl Ch L1 temperature Fan off set point from 1 to 220 RW 0 7 2 compl sign 2 compl Ch L2 temperature from 20 to 230 R 0 8 2 compl sign 2 compl Ch L2 Maximum temperature from 1 to 220 R...

Страница 42: ...gn 2 compl Ch L2 temperature from 1 to 220 R Fan off set point 2 compl sign 2 compl Ch L3 temperature from 20 to 230 R 0 13 2 compl sign 2 compl Ch cL3 maximum temperature from 1 to 220 R 0 14 2 compl sign 2 compl Ch L3 temperature from 1 to 220 R 0 15 alarm set point 2 compl sign 2 compl Ch L3 temperature from 1 to 220 R 0 16 trip set point 2 compl sign 2 compl Ch L3 temperature from 1 to 220 R 0...

Страница 43: ...us channel L1 Status See CHn status note R 0 43 0 Ch L2 status channel L2 Status See CHn status note R 0 44 0 Ch L3 status channel L3 Status See CHn status note R 0 45 0 Ch L1 story channel L1 Alarm history See CHn story note R 0 46 0 Ch L2 story channel L2 Alarm history See CHn story note R 0 47 0 Ch L3 story channel L3 Alarm history See CHn story note R 0 48 0 HFN setting fan test cycle hours 0 ...

Страница 44: ...1 L2 L3 STORY BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Not used TRIP ALARM Not used Not used Not used FOC FCC Address HI 10 Address LO 10 Data HI Data LO Note 1 Note 2 R read W write RW read write 0 51 0 Address Modbus ad dress 1 255 R 0 52 0 Bdr Modbus baud rate 0 2400 Baud R 1 4800 Baud 2 9600 Baud 3 19200 Baud 4 38400 Baud 0 53 0 Parity Modbus parity bit 0 No Parity R 1 even Parity 2 odd...

Страница 45: ...障 检查Pt100传感器的连接 可能传感器接线 不良或损坏 措施 检查或更换已损坏的传感器 当启动时 显示 ECH 错误信息 由于强干扰导致内存数据损坏或缺陷 请参阅本规范的第9条说明 如果此问题仍 然存在 请与TECSYSTEM S r l 公司技术部 门取得联系 所有的通道均处于FCC 短路 传感器报警 状态 传感器接线端子排接线错误或端子内短路 或者传感器探头所处的温度低于 15 C 所有的通道均处于FOC 开路 传感器报警 状态 传感器接线连接不良 松动脱落 或者是传感器检测到的温度超过了230 C 一个或多个通道错误温度显示 请与TECSYSTEM S r l 公司技术部门取得联 系 跳闸 TRIP 触点触发 但温度处于正常 水平 此现象是由传感器损坏或者相应接线不良引 起 通过T MAX功能查看报警故障通道 检查对应的接线端子或更换对应的传感器 21 ...

Страница 46: ...或者空转的故障状态 因此 用户应进行按不同的应用情况为FCD报警作不同的定义与应用 当温升速率超过设定的速率 n C 秒 n值 从1到30 通过激活 FCD功能 温控器可以通过输出触点54 55输出FAULT错误报警信号 通过参数设定 用户可以根据不同的使用要求选择如下不同的精度等 级 从1至10 高灵敏度 用于即时探测电动机转子失速情况 从10至20 平均灵敏度 用于监测影响传感器采集数据 线路连接不良 以及传感器缺陷等各种干扰信息 从20至30 低灵敏度 用于的场合是 高灵敏度设置可能会导致不必要 的FCD功能中的错误报警 设置 no 模式 则FCD功能被禁止 当一个通道出现FCD FAULT故障报警时 相关的高温报警 ALARM 和跳闸 TRIP 报警功能将被锁住 只是显示温度快速升高的FCD报 警 避免产生错误的高温报警 ALARM 和跳闸 TRIP 报警 按下Reset键删除所有...

Страница 47: ...寸 152 76mm 用附带的紧固件进行锁紧 图示2 控制输出连接 电压 18 36 Vdc 必须注意正负极性 仪表后面板实物图 RS485通讯输出连接 标准型产品无 RS485输出连接 白色线 红色线 红色线 1 2 3 7 8 9 4 5 6 CH L1 CH L2 CH L3 高温报警 跳闸报警 故障报警 风机无源输出 节点容 量 12A 250Vac cos Φ 1 54 55 52 53 50 51 56 57 风机控制 Gnd 62 61 60 41 42 特别说明 通电时故障报警继电器将断开 断电后或故障发生时故障报警继电器将闭合 ...

Страница 48: ...质保期 如在质保期内发生因产品 本身的生产工艺不符 校准不良等原因造成的质量问题或泰狮智能温控 上海 有限公司的自身原因造成的产品不良 我们将免费维系或更 换 如果是客户不按使用说明使用操作或其它客户原因造成的产品不良 不 属于免费保修范围 如需维修或更换 客户需承担相关费用 注意 为了保护环境 废旧产品 需要隔离送废品回收处 或返回我司进行专 业回收处理 24 NT579 NT579 RS485 智能温控器 TECSYSTEM SHANGHAI ...