![TECOM TS1066 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/tecom/ts1066/ts1066_programming-manual_1072587076.webp)
When selected, the override time zone takes cannot unlock the door for the
programmed times unless a user has entered.
Disable duress
Whe
n selected, the system’s keypad duress functionality cannot be used at this
door.
Time & attendance reader
When selected, the reader can be used as a time and attendance reader. See
the “Using time and attendance readers” section on page 98 for more
information.
Note:
Some management software applications do not support time and
attendance functionality.
Report DOTL
When selected, a report is sent to management software when the
door’s
Door
input 1
is in the door open too long (DOTL) state. For example, the door is still
open after the shunt timer expires.
This is only a reporting function.
Report forced door
When selected, a report is sent to management software when the
door’s
Door
input 1
is unsealed without valid access (card, PIN, or egress request).
This is only a reporting function.
Report door open/close
When selected, a report is sent to management software when the
door’s
Door
input 1
is unsealed (opened) or resealed (closed).
This is only a reporting function.
Report secured/accessed
When selected, an “unsecured” (i.e. accessed) message is sent to management
software if the door is unsecured, which occurs in any of the following situations:
Access to the door is granted to a user
The door
’s shunt timer is running
The door is forced
The door is opened from management software
The door is unlocked from management software
A “secured” message is sent to management software when the door is secured.
This is only a reporting function.