Chapter 3 Program Tools
54
(4) SET (system setting)
content
default
ID SET
01
Æ
ID setting (00~99)
REMOTE I/O
N
Æ
Remote I/O Mode
(N: none M: Master S: Slave)
BACK LIGHT
×
Æ
Back light mode
(
√
: always light ×: light for 10s after pressed.)
M KEEP
√
Æ
M: non-Volatile (
√
:Volatile ×: Non- Volatile)
I/O NUMBER
0
Æ
Setting expansion I/O module number (0~3)
I/O ALARM
√
Æ
Siren setting when is not available to Expansion
I/O Points (
√
:Yes ×:No)
C KEEP
×
Æ
in stop/run switching, Counter Present Value
Keeping (
√
:Yes ×:No)
Z SET
×
Æ
Enable or disable keypad input Z01-Z04
(
√
:enable ×:disable)
RS485 SET
03
Æ
Setting the form and baud rate of RS-485
DATA REG.
U
Æ
Setting the Data Register type
(U: 16bit-unsiged S: 16bit-sign)
※
M KEEP function is available for keeping M status and current value of T0E/T0F when power is re-supplied
after loss.
Now Press:
↑
↓
←
→
Move the cursor
SEL
Begin to edit.
‘SEL’ then ‘
←
/
→
’
Move the cursor for ‘ID SET’ item and ‘RS485 SET’ item
‘SEL’ then ‘
↑
/
↓
’
1. ID SET = 00~99 ; I/O NUMBER = 0~3
2. REMOTE I/O = N
⇔
M
⇔
S
⇔
N
3. BACK LIGHT ; C KEEP ; Z SET = ×
⇔
√
4. M KEEP; I/O ALARM =
√
⇔
×
5. RS485 SET = (0~3)(0~5)
6. DATA REG. = U
⇔
S
OK
Confirm the Edition Data
ESC
1. Cancel the setting when pressed ‘SEL’
2. Back to Main Menu(save edit data)
※
When IO LINK is selected, ID setting range is 0~7, which should be continuous.
ID=0 default as Master, ID=1~7 default as Slave.
※
When REMOTE I/O is selected, the distribution of the remote I/O is as follows:
Master Slave
Remote Input
X01~X0C
←
I01~I0C
Remote Output
Y01~Y08
→
Q01~Q08
※
The high bit of RS485 SET detects the form of RS-485, and the low bit detects the baud rate of RS-485.
More detailed to see
chapter 7: 20 Points RS485 type Models Instruction
.
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor