Страница 1: ...Keep these important operating instructions Check www tecnare com for updates Operation Manual Compact Multipurpose Loudspeaker IBZA10 IBZA Series Version 2 5 Release 2017 ...
Страница 2: ......
Страница 3: ...responsibility for any errors or inaccuracies that may appear in this manual or the products and software described in it Technical specifications dimensions weights and properties do not represent guaranteed qualities As manufacturers we reserve the right to make alterations and modifications within the framework of legal provisions as well as changes aimed at improving quality EXEL ACOUSTICS SL ...
Страница 4: ...nual before installing the system Use the rigging accessories described in the rigging manual a follow the associated procedures CAUTION Rigging should only be done by experience professionals 10 This speaker enclosure is capable of creating a strong magnetic field Please use caution around the enclosure with data storage devices such as phones computers or hard drivers 11 Handles are for moving t...
Страница 5: ...A10 y sus respectivas opciones cumple con las Directivas Declare under our sole responsibility that devices in the IBZA10 range of products comply with relating Directives 1 Directiva de Baja Tensión 2006 95 CE 2 Directiva de Compatibilidad Electromagnética 2004 108 CE 3 Directiva RoHS 2011 65 UE 4 Directiva RAEE 2012 19 UE 1 Low Voltage Directive 2006 95 CE 2 EMC 2004 108 CE 3 RoHS Directive 2011...
Страница 6: ...speaker Configuration 11 2 1 Configurable Asymmetrical Horn 11 2 2 Point Source 11 2 3 Point Source with low frequency element 12 2 4 Rotating the Horn 13 2 5 Recommended Speaker Cables 14 3 Amplifier Configuration 15 3 1 Connection to PA4 450 15 3 2 Connection to PA900 PA2100 16 3 3 Connection to T 44 Series 16 4 Integrating IBZA10 Using Subwoofers 17 4 1 Integrating IBZA10 Loudspeakers Systems w...
Страница 7: ...her information about this or any other Tecnare product please contact us We look forward to helping you in the near future As part of a continuous evolution of techniques and standards Exel Acoustics SL as manufacturer of Tecnare products reserve the right to change the specifications of its products and the content of its documents without prior notice Updates and supplementary information are a...
Страница 8: ...onstitutes a broad range of point source full range loudspeakers that providing high SPL different directivities patterns and a good sonic performance off axis The IBZA Series is suited to various sound reinforcement applications as a main or complementary system IBZA Series enclosures are easy to integrate combining sonic character with style Its aesthetic appearance makes it ideal for the most d...
Страница 9: ... the IBZA10 in full range mode or combined with Tecnare subwoofers The full range compact IBZA10 loudspeaker offers total versatility between all types of near field listening applications stage monitoring distributed systems in fill near fill delay etc PA with or without subwoofers IBZA10 is designed for small to medium size venues or as a distributed system Its compactness and sonic performance ...
Страница 10: ...connectors Only two pins 1 1 of both connectors are wired in parallel The following subsections describe the electrical connections Other configuration should be requested at the purchase time The IBZA10 uses the pin assignment 1 1 Using one as the input the second connector allows for direct connection to a second cabinet in parallel Internal pinout for IBZA10 enclosures IN speakON point 1 1 2 2 ...
Страница 11: ...pplications it is recommended to oversize the amplifiers relative to the nominal AES output of the loudspeakers A lower power amplifier will not reduce the chances of driver damage due to over excursion and may actually increase the risk of thermal damage due to sustained clipping In certain specific cases it is possible to slightly under power the subs or loudspeakers as long as the amplifier wil...
Страница 12: ...eature of the IBZA10 The horn can be rotated in four different positions and can be useful for specialized applications such as complex arrays systems designed with CAD software etc Ensure that the loudspeakers are securely attached to prevent personal injury and property damage NOTE TECNARE recommends using only the accessories specified by TECNARE to secure the loudspeakers 2 2 Point Source In t...
Страница 13: ...th with same factory preset as in point source configuration The subwoofer will be operating with its corresponding factory preset The upper frequency limit must be 100 Hz for an optimal acoustic coupling with the enclosure If your IBZA10 loudspeakers and subwoofers are separated by a greater distance or delay must be used between them a measurement system such as SMAART should be used to determin...
Страница 14: ...e per side from IBZA10 using a hex key 3 Carefully remove the grille 4 Release the four 4 screws of the horn using a hex key Pull the horn and the compression driver upward out of the loudspeaker enclosure being careful not to over stress its wiring 5 Check that the seal between the enclosure and horn is properly seated 6 Rotate the horn carefully on the desired position and place the horn and dri...
Страница 15: ...or variations INSERTION LOSS Insertion loss is the measure of the loss of load power at the speaker due to excessive resistive losses of the cable or any additional component attached between the amplifier and the loudspeaker We typically express this loss in decibels dB using the following formula 20 log Rload IL Rload Rcable DAMPING FACTOR Damping factor is a ratio of rated loudspeaker impedance...
Страница 16: ...ios del Monte Toledo SP AIN Tl 3491 8 17011 0 M AD E IN SP A IN SPEA KO N 1 1 SPEA KO N 1 1 IBZA10 400W AES 8 OH M 150101 00 1 C E ncinar 282 Pol Ind Mo nte Boyal 45950 Casarrubios del Monte Toledo SP AIN Tl 3491 8 17011 0 M AD E IN SP A IN SPEA KO N 1 1 SPEA KO N 1 1 IBZA10 400W AES 8 OH M 150101 00 1 C E ncinar 282 Pol Ind Mo nte Boyal 45950 Casarrubios del Monte Toledo SP AIN Tl 3491 8 17011 0 ...
Страница 17: ... single T 44 amplifier controller can drive up to 16 enclosures A single T 48 amplifier controller can driven 32 enclosures Impedance load 8Ω for 1 enclosure 4Ω for 2 enclosures 2Ω for 4 enclosures IBZA10 4 00 W AES 8O H M 1 5 0 1 0 1 00 1 S P E A K O N 1 1 S P E A K O N 1 1 IBZA10 4 00 W AES 8O HM 1 5 0 1 0 1 00 1 S P E A K O N 1 1 S P E A K O N 1 1 IBZA10 4 00 W AES 8O HM 1 5 0 1 0 1 00 1 S P E ...
Страница 18: ...st application a ratio of two IBZA10 for each SW 115 or SW 118M subwoofer and four IBZA10 for each SW215 subwoofer yield good results in frequency response and headroom 4 2 Signal Delay If IBZAs loudspeaker and subwoofers are used in their full range configuration together DP Series Loudspeaker controlled or T Series Amplifier use the factory preset setting if they are co planar or near to each ot...
Страница 19: ...edance 8Ω Throat diameter 25mm 1 75 inch 44 3 mm voice coil diameter Power Handling Capability 100 W AES 200 W continuous Note Power Handling measured using AES Standards 2 hours test made with continuous pink noise signal 6 db crest factor AUDIO INPUT Connectors IN 1 x NL4 SpeakON LINK 1 x NL4 SpeakON Wiring Pin 1 Input Signal Pin 2 NC PHYSICAL Enclosure 16mm birch plywood Finished in Polyurea su...
Страница 20: ...Operation Manual 19 IBZA Series rev 2 5 IBZA10 Dimensions ...
Страница 21: ...or liability for any errors or inaccuracies that may appear in this manual Except as permitted by applicable copyright law no part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without prior written permission from Exel Acoustics Tecnare and PCC Net are trademarks of Exel Acoustics SL Podwa...