background image

Keep these important operating instructions.

Check www.tecnare.com for updates.

Operation Manual

Full-Range Compact Multipurpose Loudspeaker

IBZA6

IBZA Series

Version 2.5

Содержание IBZA P204

Страница 1: ...Keep these important operating instructions Check www tecnare com for updates Operation Manual Full Range Compact Multipurpose Loudspeaker IBZA6 IBZA Series Version 2 5 ...

Страница 2: ......

Страница 3: ...responsibility for any errors or inaccuracies that may appear in this manual or the products and software described in it Technical specifications dimensions weights and properties do not represent guaranteed qualities As manufacturers we reserve the right to make alterations and modifications within the framework of legal provisions as well as changes aimed at improving quality EXEL ACOUSTICS SL ...

Страница 4: ...nual before installing the system Use the rigging accessories described in the rigging manual a follow the associated procedures CAUTION Rigging should only be done by experience professionals 10 This speaker enclosure is capable of creating a strong magnetic field Please use caution around the enclosure with data storage devices such as phones computers or hard drivers 11 Handles are for moving t...

Страница 5: ...ZA6 y sus respectivas opciones cumple con las Directivas Declare under our sole responsibility that devices in the IBZA6 range of products comply with relating Directives 1 Directiva de Baja Tensión 2006 95 CE 2 Directiva de Compatibilidad Electromagnética 2004 108 CE 3 Directiva RoHS 2011 65 UE 4 Directiva RAEE 2012 19 UE 1 Low Voltage Directive 2006 95 CE 2 EMC 2004 108 CE 3 RoHS Directive 2011 ...

Страница 6: ...4 Connections 9 1 5 Processing and Amplification 10 2 Loudspeaker Configuration 11 2 1 Point Source 11 2 2 Point Source with low frequency element 11 3 Configuration 13 3 1 Connection to PA4 450 13 3 2 Connection to PA900 14 3 3 Connection to T 44 Series 14 4 Integrating IBZA6 Using Subwoofers 15 4 1 Integrating IBZA6 Loudspeakers Systems with Tecnare Subwoofers 15 4 2 Signal Delay 15 5 Technical ...

Страница 7: ...her information about this or any other Tecnare product please contact us We look forward to helping you in the near future As part of a continuous evolution of techniques and standards Exel Acoustics SL as manufacturer of Tecnare products reserve the right to change the specifications of its products and the content of its documents without prior notice Updates and supplementary information are a...

Страница 8: ... constitutes a broad range of point source full range loudspeakers that providing high SPL different directivities patterns and a good sonic performance off axis The IBZA Series is suited to various sound reinforcement applications as a main or complementary system IBZA Series enclosures are easy to integrate combining sonic character with style Its aesthetic appearance makes it ideal for the most...

Страница 9: ... IBZA6 can be used for vocal reinforcement front fill coverage and delay coverage for under balcony applications Its wide conical directivity pattern gives smooth off axis response assuring the best sound where most of the audience is located The IBZA6 can also be paired with an optional subwoofer to create a full range system Available series in a grey colour or white custom colour the IBZA6 can ...

Страница 10: ...e cable connectors Only two pins 1 1 of both connectors are wired in parallel The following subsections describe the electrical connections Other configuration should be requested at the purchase time The IBZA6 uses the pin assignment 1 1 Using one as the input the second connector allows for direct connection to a second cabinet in parallel IN speakON point 1 1 2 2 Connection LF LF NC NC Internal...

Страница 11: ... the loudspeakers For high power or live applications it is recommended to oversize the amplifiers relative to the nominal AES output of the loudspeakers A lower power amplifier will not reduce the chances of driver damage due to over excursion and may actually increase the risk of thermal damage due to sustained clipping In certain specific cases it is possible to slightly under power the subs or...

Страница 12: ...sponse of the IBZA6 is extended in the low end IBZA6 enclosure is driven by the PA4 450 PA900 amplifier with the DP Series Processor or T 44 T 48 Series amplifier controller both with same factory preset as in point source configuration The subwoofer will be operating with its corresponding factory preset The upper frequency limit must be 110 Hz for an optimal acoustic coupling with the enclosure ...

Страница 13: ...Operation Manual IBZA Series rev 2 50 12 IBZA6 SW 118M Frequency Range 6dB 40 20Hz Recommended ratio 1xSW 118M 4xIBZA6 ...

Страница 14: ... preset was selected before connecting the loudspeaker with the amplifier Operating with an incorrect preset can damage part of the loudspeaker Ensure that the amplifier is properly size according to requirements Under power or oversize power amplifier without the supervision of an expert may damage the loudspeaker Please note the technical specification section 3 1 Connection to PA4 450 MAXIMUM O...

Страница 15: ...res Impedance load 8Ω for 1 enclosure 4Ω for 2 enclosures 3 3 Connection to T 44 Series MAXIMUM OF 16 ENCLOSURES PER T 44 4 x IBZA6 can be connected to each output channel on the T 44 T 48 Series amplifier Therefore a single T 44 amplifier controller can drive up to 16 enclosures A single T 48 amplifier controller can driven 32 enclosures Impedance load 8Ω for 1 enclosure 4Ω for 2 enclosures 2Ω fo...

Страница 16: ...cation a ratio of two IBZA6 for each SW 12 subwoofer and four IBZA6 for each SW115 or SW 118M subwoofer yield good results in frequency response and headroom 4 2 Signal Delay If IBZAs loudspeaker and subwoofers are used in their full range configuration together DP Series Loudspeaker controlled or T Series Amplifier use the factory preset setting if they are co planar or near to each other For oth...

Страница 17: ...r on symmetric horn Nominal impedance 8Ω Voice coil size 1 inch Power Handling Capability 30 W AES 60 W continuous Note Power Handling measured using AES Standards 2 hours test made with continuous pink noise signal 6 dB crest factor AUDIO INPUT Connectors IN 1 x NL4 SpeakON LINK 1 x NL4 SpeakON Wiring Pin 1 Input Signal Pin 2 Parallel PHYSICAL Enclosure 16mm birch plywood Finished in Polyurea sur...

Страница 18: ...Operation Manual 17 IBZA Series rev 2 50 IBZA6 Dimensions ...

Страница 19: ...Operation Manual IBZA Series rev 2 50 18 ...

Страница 20: ...or liability for any errors or inaccuracies that may appear in this manual Except as permitted by applicable copyright law no part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without prior written permission from Exel Acoustics Tecnare and PCC Net are trademarks of Exel Acoustics SL Podwa...

Страница 21: ...50 2018 EXEL ACOUSTICS SL CL Encinar 282 Pol Ind Monte Boyal 45950 Casarrubios del Monte To Spain e support tecnare com www tecnare com www facebok com tecnare T 34 918 170 110 34 918 171 001 F 34 918 183 053 ...

Отзывы: