TE70 IR-HEATER
PAGE 21
7.0 ERROR MESSAGES
Heating tool not connected to the inverter.
Warns that the start button was pressed when
powering-on the machine or right after connecting the
heating tool. Release the start button to restore
machine operation.
Indicates, at the end of a machine use stage, not to
disconnect the system from the power supply mains to
allow the heating tool to cool down properly. This stage
requires 5 minutes. You can press the START button at
any time to resume the heating process. You can delete
the warning message by touching the touch screen in
case you want to change the control unit's settings.
IGBT FAIL
MACHINE LOCKED
Power inverter error. Check the integrity of the
connection cable between the power box and the
heating tool. Contact customer support.
TEMP
Warns there is an overheating in the power inverter or
the heating tool. Wait until the error message clears,
without powering off the machine. Check the
cleanliness of the cooling fan on the side of the power
box.
Check the correct water and air flow to the heating tool.