S.p.A.
TE470/TE480 Instruction
Manual
3.1 – EXAMPLES OF WORK PROGRAMS
4 TIMES SIMPLE CYCLE, SHORT STROKE, SINGLE CYCLE
NUMBER PARAMETER VALUE
TO WORKING
MODE
PW%
B CONTROL
MODE
NO
C STROKE
SHORT
1
SQUEEZE 1
10 cycles
2 SQUEEZE
20
cycles
3 PRE-WELD
00
cycles
4
POWER 1
05 %
5
COLD 1
00 cycles
6
SLOPE UP
00 cycles
7 WELD
16
cycles
8 POWER
40
%
9 IMPULSE
N.
01
10
COLD 2
00 cycles
11
SLOPE DOWN
00 cycles
12
COLD 3
00 cycles
13 POST-WELD
00
cycles
14
POWER 2
05 %
15
HOLD TIME
09 cycles
16
OFF TIME
00 cycles
02
07
15
1
2
08
CYCLE WITH PULSES AND SLOPE UP, LONG STROKE, AUTOMATIC CYCLE
NUMBER PARAMETER VALUE
TO WORKING
MODE
PW%
B CONTROL
MODE
NO
C STROKE
LONG
2 SQUEEZE
30
cycles
3 PRE-WELD
00
cycles
4
POWER 1
05 %
5
COLD 1
00 cycles
6
SLOPE UP
06 cycles
7 WELD
04
cycles
8 POWER
40
%
9 IMPULSE
N.
03
10
COLD 2
03 cycles
11
SLOPE DOWN
00 cycles
12
COLD 3
00 cycles
13 POST-WELD
00
cycles
14
POWER 2
05 %
15
HOLD TIME
09 cycles
16
OFF TIME
35 cycles
02
10
06
07
10
07
15
16
1
2
08
07
08
08
02
09
32/52