![TECNA TE1700 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/tecna/te1700/te1700_user-manual_1071489028.webp)
TECNA WELD TESTER TE1700
2.6 SETTING LIMITS
LIMIT - A control mask is associated with each acquired weld spot, with
three weld limits that may be selected among the following quantities:
current
,
energy
,
time
,
force
and
displacement
. You cannot select two
identical quantities from the limits mask. If using the TE1710 Expander,
you can configure up to 15 limits masks through the control unit's call
signals.
Enables access to the welding limit programming menu.
PAGE 28