T
ROUBLESHOOTING
Problem
Possible cause
Possible solution
The motor is turning, but the
electrical panel is switched off.
No power.
Verify that the power cord is connected
and intact.
The internal thermal protection of
the motor have been activaded.
Unplug the unit, wait an hour before
connecting again, verify the functioning.
If not working change the motor.
Emergency button pressed.
Relase the button, and press the start
button.
The electrical panel is not
working in all or in some of the
buttons.
Possibile tension overload.
Remove the power plug, wait a couple
of minutes before reinsert the plug, and
operate the equipment.
Failure on the electrical panel.
Replace the electrical panel.
The motor is turning, but dose
not transmit the rotation to the
vertical shaft.
Loose belt.
Adjust the belt tension.
Feather key missing or broken on
the reducer shaft.
Replace /insert the feather key.
Transmission joint broken or
unhooked.
Verify the connection between the
various joints.
Noise machine.
Belt to tight.
Ajust the belt tession.
Machine not correctly positioned.
The feets are not adjusted
correctly.
Adjust the feets.
The panel is on, but the motor
is not working.
Fuse blown.
Change fuse.
For any other kind of issues, or doubts, please contact the Customer Service Dep. in Tecmec.