Techogas Superiore RN362GPSS Скачать руководство пользователя страница 1

461308462  07-2015

INSTALLATION MANUAL FOR 

30’’ AND 36’’ GAS RANGES

Содержание Superiore RN362GPSS

Страница 1: ...461308462 07 2015 INSTALLATION MANUAL FOR 30 AND 36 GAS RANGES...

Страница 2: ...USA 23 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any e...

Страница 3: ...wn to the State of California to cause cancer and birth defects or other reproductive harm California law requires this warning to be given to customers in the State of California An air curtain or ot...

Страница 4: ...uit no other receptacles switches or loads in the circuit Connected to a standard breaker of appropriate size GFI breaker of the same size NOT recommended Rated for Class A 5 mA 1 mA trip current as p...

Страница 5: ...r death verify your appliance has been properly grounded in accordance with local codes or in absence of codes with the National Electrical Code NEC ANSI NFPA 70 latest edition WARNING WARNING DANGER...

Страница 6: ...imensions 30 Gas Ranges Note Unit shown with island trim Note All gas ranges are equipped with spacer on the back 25 64 to prevent over heating of the wall 29 7 8 23 2 2 3 16 35 7 8 min 37 5 16 max 1...

Страница 7: ...30 Gas Ranges 2 25 2 2 1 1 2 5 Gas 33 1 11 32 2 6 8 1 3 8 29 7 8 29 7 8 3 8 Electricity 2 1 8 5 5 9 16 35 7 8 min 37 5 16 max 26 7 8 2 3 8 3 8 23 2 3 16 2 1 8 1 11 32 35 15 32 min 36 7 8 max 2 6 8 min...

Страница 8: ...ensions 36 Gas Ranges Note Unit shown with island trim Note All gas ranges are equipped with spacer on the back 25 64 to prevent over heating of the wall 35 7 8 min 37 5 16 max 35 7 8 23 2 33 2 3 16 1...

Страница 9: ...6 Gas Ranges 35 7 8 min 37 5 16 max 2 2 33 35 7 8 2 1 8 25 2 2 Gas 1 3 8 35 7 8 Electricity 5 5 9 16 1 1 2 5 1 11 32 2 6 8 3 8 26 7 8 2 3 8 3 8 23 2 3 16 2 1 8 1 11 32 35 15 32 min 36 7 8 max 2 6 8 mi...

Страница 10: ...t Interior dimensions 2413 64 x 1957 64 x 2031 64 Burners injectors and volume ranges 36 mod 361 and 362 Natural 4 LP Propane11 By pass Inj W BTU h Inj W BTU h W BTU h Small burner 92 1055 3600 56 105...

Страница 11: ...ximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Wall cabinets above the range must be a minim...

Страница 12: ...efer to the range hood installation instructions for additional information These dimensions provide for safe and efficient operation of the hood Important There must be a minimum of 6 15 2 cm clearan...

Страница 13: ...husetts A T handle type manual valve must be installed in the gas supply line to the appliance IMPORTANT Any conversion required must be performed by your dealer or a qualified licensed plumber or gas...

Страница 14: ...ressure regulator 3 Screw the assembled pressure regu lator on the range like shown on picture below Pay attention to the vertical aligne ment of the same pressure regulator Gas Requirements 4 Re inst...

Страница 15: ...fied flexible connector or at least1 2 1 3 cm ID NPT with suitable strainreliefs in compliance with ANSI Z21 41and Z21 69 G area for gas connection E area for electric connection In Canada CAN 1 6 10...

Страница 16: ...rinted on the body Consult the table on Specifications Technical data paragraph for matching nozzles to burners Save the nozzles removed from the range for future use STEP1 PRESSURE REGULATOR The pres...

Страница 17: ...d on the body Consult the table on Specifications Technical data paragraph for matching nozzles to burners STEP 3 MAIN OVEN BURNER To replace the nozzles of the main oven burner start by removing the...

Страница 18: ...2 screws on left and right sides and pull out the burner from its support burner from its support ATTENTION pay extra attention to avoid damage to the igniter and thermocouple For range 30 Using a 7 m...

Страница 19: ...and proceed to setting the minimum for each burner Gas Requirements STEP 6 MINIMUM FLAME ADJUSTMENT WARNING These adjustments should be made only for use of the appliance with natural gas For use wit...

Страница 20: ...nutes 3 Set the knob to the MINIMUM setting 4 Remove the knob 5 With a slotted screwdriver turn the choking screw bypass screw at the left side of the thermostat bar and while observing the flame at t...

Страница 21: ...and must be installed with the unit Refer to An ti tip Device Installation section Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be washed...

Страница 22: ...must be done by your dealer a qualified licensed plumber or certified gas installer Door Removal 1 Open the door completely Place the pins supplied with unit in pin hole For personal safety ONLY use p...

Страница 23: ...contai ner situated over the appliance Before installing the legs position the appliance near its final location as the legs are not suitable for moving the appliance over long distances After unpack...

Страница 24: ...th the installation instructions in this document Device must be engaged properly to prevent product from tipping over Anti tip Device Installation Measure from floor to the anti tip bar located in a...

Страница 25: ...ation always check for gas leaks with soapy water solution DO NOT USE AN OPEN FLAMETO CHECK FOR GAS LEAKS Connect gas and electrical Before placing appliance in operation always check for gas leaks Th...

Страница 26: ...scrape stainless steel Scratches arealmost impossible to remove Performance Checklist A qualified installer should carry out the following checks Check top burner ignition Push and turn the knob Full...

Страница 27: ...ratures Broil Broil Gas oven switch knob range 36 OFF Closed position from MIN to MAX 300 500 F Oven temperatures Broil Broil OFF Closed position Full on position internal ring Full on position estern...

Страница 28: ...write to CUSTOMERCARE TECNOSPA IT Record the information indicated below You will need it if service is ever required The model and serial number can be found by looking in the last page of this book...

Страница 29: ...ll labor and in home service to repair or replace the defective part This warranty is extended to the original purchaser and any succeeding owner with proper documentation of ownership for products pu...

Страница 30: ...acts of God 16 Expenses for travel and transportation to locations more than 30 miles from an authorized TECNOGAS SUPERIORE retailer 17 Products with original serial numbers that have been removed The...

Страница 31: ...31 461308462 07 2015 Electric diagram 30...

Страница 32: ...32 Electric diagram 36 6 burners...

Страница 33: ...33 461308462 07 2015 Electric diagram 36 4 burners griddle...

Страница 34: ...34 INSTALLATION LABEL CONVERSION LABEL Labels...

Страница 35: ...35 461308462 07 2015...

Страница 36: ...tecnogassuperiore us...

Отзывы: