![Technoton DUT-E S7 Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/technoton/dut-e-s7/dut-e-s7_operation-manual_1070695061.webp)
DUT-E S7 Radiobox RS wireless interface / Configuration / Summarization of readings of DUT-E S7 wireless sensors
DUT-E S7 fuel level sensor. Operation manual. Version 4.0
©
Technoton, 2021
61
7.6.4 Summarization of readings of DUT-E S7 wireless sensors
can summarize volume readings of the two tanks
in which
wireless fuel level sensors are installed.
For summarization of DUT-E S7 sensors readings, load the profile of DUT-E S7 Radiobox RS
into the Service S6 DUT-E software; tick the fields
Tank 1
and
Tank 2
in the settings of the
submenu
Fuel Level Control
FM
) and save the profile in the Unit.
The current value of the total volume of fuel in the selected tanks must be displayed in the line
Summary Value. Fuel Tank Volume, l
(see figure 34).
Figure 34
—
Configuration of DUT-E S7 Radiobox RS
for summarization
of DUT-E S7 readings using S7 Technology
IMPORTANT:
For correct summarization of fuel volume readings, the profile of each
of the DUT-E S7 sensors operating together with DUT-E S7 Radiobox RS must contain
the calibration parameters (“Empty” and “Full” frequencies), as well as the calibration
table of the respective tank.
The procedures of calibration and creation of calibration tables are carried out using
Service S6 DUT-E software similar to the respective procedures for
You can manually enter values of the calibration frequencies “Empty” and “Full” into the
memory of DUT-E S7 Radiobox RS in the submenu of the
Fuel level sensor FM
(
Calibration
) (e.g. using readings of the Android device, see
). To enter the frequencies,
tick the field
Enter calibration parameters
, press
button and select
Enter
manually
(see figure 35).
You can also enter values of the calibration frequencies “Empty” and “Full” for the sensors
profiles into the memory of DUT-E S7 Radiobox RS by loading a special file
DUT-E_*.cal
(
*
—
serial number of the respective sensor) generated in advance (using
button).
In order to load the file, press
button and choose
Load from file
.
Tick
Total fuel volume
in two tanks