1.4.2 Data composition of DUT-E S7 output message
wireless fuel level sensor transmits data by means of
, without
integration with receiving devices and without acknowledgement of data reception.
The data in the form of Advertising packets are transmitted automatically with 5 s periodicity
in the continuous data transfer mode. The structure of the data packet transmitted by
DUT-E S7 is provided in figure 7.
Service field (AD0)
(permanent values)
Data field (AD1)
(variable values)
Data length
(AD Length)
(1 byte)
Data type
(AD Type)
(1 byte)
Data
(Data)
(1 byte)
Data length
(AD Length)
(1 byte)
Data type
(AD Type)
(1 byte)
Company
identifier
(Company ID)
(2 bytes)
Unit firmware
version
(Soft Ver)
(1 byte)
PGN
number
(PGN)
(2 bytes)
PGN data
(PGN Data)
(0…21 bytes)
0x02
0x01
0x06
0xXX
0xFF
0xFFFF
0xXX
0xXXXX
…
Figure 7
—
Structure of data packet transmitted by DUT-E S7
The application layer of the output message protocol of DUT-E S7 conforms with
(see table 2)
Table 2
—
Data composition of DUT-E S7 output message
Field
number
Length Parameter
Name
1
4 bytes
2
1 byte
, °C
3
2 bytes
Lateral acceleration extended range, m/s
2
4
2 bytes
Longitudinal acceleration extended range, m/s
2
5
2 bytes
Vertical acceleration extended range, m/s
2
6
4 bytes
8
6 bytes
-
Reserve
*
In the process of preparation for introduction.
Table 3
—
Numerical values of malfunction mask (DTCs Mask) of DUT-E S7
Numerical
value
Description of malfunction
1
Fuel temperature. No data or incorrect data
64
Current frequency of sensor’s
measuring generator is higher by more than
100 Hz, compared to the stored value obtained during the calibration of the
sensor’s “minimum”
512
Defective measuring generator. Possible locking of the measuring module pipes
1024
Low battery charge (<10 %)
2097152
Real time clock. Clocking is off