Technosoft 2014
16
iPOS360x MX Technical Reference
2.5.7.
Motor Outputs (A/A+, B/A-, C/B+, BR/B-)
Min.
Typ.
Max.
Units
Nominal output current, continuous
for DC brushed, steppers and
BLDC motors with Hall-based
trapezoidal control
iPOS3604
4
A
iPOS3602
2
for PMSM motors with FOC
sinusoidal control (sinusoidal
amplitude value)
iPOS3604
4
iPOS3602
2
for PMSM motors with FOC
sinusoidal control (sinusoidal
effective value)
iPOS3604
2.82
iPOS3602
1.41
Motor output current, peak
maximum 2.5s
iPOS3604
-10
+10
A
maximum 24s
iPOS3602
-3.2
+3.2
A
Short-circuit protection threshold
measurement range
iPOS3604
±13
±15
A
iPOS3602
±4.3
±5
Short-circuit protection delay
5
10
S
On-state voltage drop
Nominal output current; including typical
mating connector contact resistance
±0.3
±0.5
V
Off-state leakage current
±0.5
±1
mA
Motor inductance (phase-to-phase)
Recommended value, for
ripple ±5% of measurement
range; +V
MOT
= 36 V
F
PWM
= 20 kHz
250
H
F
PWM
= 40 kHz
120
F
PWM
= 60 kHz
100
F
PWM
= 80 kHz
60
F
PWM
= 100 kHz
45
Absolute minimum value,
limited by short-circuit
protection; +V
MOT
= 36 V
F
PWM
= 20 kHz
75
H
F
PWM
= 40 kHz
25
F
PWM
= 60 kHz
20
F
PWM
= 80 kHz
10
F
PWM
= 100 kHz
5
Motor electrical time-constant (L/R)
Recommended value, for
±5% current measurement
error due to ripple
F
PWM
= 20 kHz
250
µs
F
PWM
= 40 kHz
125
F
PWM
= 60 kHz
100
F
PWM
= 80 kHz
63
F
PWM
= 100 kHz
50
Current measurement accuracy
FS = Full Scale
±4
±8
%FS
2.5.8.
Digital Inputs (IN0, IN1, IN2/LSP, IN3/LSN, IN4/Enable)
Min.
Typ.
Max.
Units
Mode compliance
TTL / CMOS / LVTTL (3.3V) / Open-
collector / NPN / 24V outputs
Default state
Input floating (wiring disconnected)
Logic HIGH
Input voltage
Logic “LOW”
0
0.8
V
Logic “HIGH”
2
5÷24
Floating voltage (not connected)
3
Absolute maximum, continuous
-10
+30
Содержание iPOS360x MX
Страница 2: ......
Страница 4: ......
Страница 13: ... Technosoft 2014 XI iPOS360x MX Technical Reference This page is empty 1 Safety information ...
Страница 44: ... Technosoft 2014 32 iPOS360x MX Technical Reference Figure 3 4 Axis ID Setting Examples CANopen mode ...
Страница 45: ... Technosoft 2014 33 iPOS360x MX Technical Reference Figure 3 5 Axis ID Setting Examples TMLCAN mode ...
Страница 69: ... Technosoft 2013 57 iPOS360x MX Technical Reference Figure 3 23 Multiple Axis CAN network ...
Страница 114: ... Technosoft 2013 102 iPOS360x MX Technical Reference This page is empty ...
Страница 115: ......