background image

SNOOZE key 

DCF icon for 
time reception 

   

    

  

 

      

WEATHER FORECAST MEMO  

ALARM CLOCK 

Instructions manual 

 

INTRODUCTION: 

Congratulations on purchasing this state-of-the-art Weather forecast 
memo alarm clock with radio controlled time. The operation of this 
product is simple and straightforward and by reading this manual, 
users will receive the optimum benefits of all its features. 

 

Memo Temperature Alarm Clock 

 
 
 
 
 
 

 
 
 
 
FEATURES: 

 

 

DCF-77 Radio controlled clock 

 

 

24 hours time 

 

 

Calendar display (date, month, weekday) 

 

 Memo 

alarm 

 

 

 

Snooze setting (2-15 minutes) 

 

 

Time zone setting (±9h) 

 

 

Weather forecast with weather tendency indicator 

 

 Indoor 

temperature 

 

 Table 

standing 

 

SETTING UP: 

1.  Firstly, slide open the battery cover at the back of the alarm 

clock as indicated above. 

2.  Checking the correct polarization, insert 1 x AA, IEC LR6, 1.5V 

battery into the battery compartment and replace the cover. 

3.  Once the battery is in place, all segments of the LCD will light up 

briefly and a short signal tone will sound. Then the time as “0:00” 
and the indoor temperature will be displayed. If the indoor 
temperature is not displayed after a few seconds, remove the 
battery and wait for at least 10 seconds before reinserting it. 

4.  If after 10 minutes the DCF time has not been received, reset the 

alarm clock and manually enter the time. The clock will 
automatically attempt each hour to receive the DCF time. When 
this is successful, the received time will override the manually 
set time. The date is also updated with the received time (Please 
refer also to notes on “

Radio controlled time

” and “

Manual 

time setting

”). 

 

FUNCTION KEYS: 

The alarm clock has four easy to use function keys: 

 

SNOOZE key 

 

 

To display the current alarm time if pressed and held for 2 
seconds in normal display mode 

 

 

To activate/de-activate the snooze function

 

 

 

To exit the manual setting modes

 

 

AL/HR key 

 

 

To enter the Alarm setting mode if pressed and held for 2 
seconds 

 

 

To display the current alarm time in normal display if pressed 
briefly 

 

 

To changes the hour, time zone, day and weekday setting in 
manual set modes  

 

 

To activate the alarm ON/OFF 

 

 

To store the current alarm time

 

 

 

To stop the alarm 

 

MODE/MIN key 

 

 

To toggle between 4 display modes: 

 Indoor 

temperature 

  

Seconds  

 

Date and month (only displayed when time zone is set to 
"0h“) 

 

Weekday and date (only displayed when time zone is set to 
“0h”) 

 

 

To enter the Time zone setting mode if pressed and held for 
2 seconds 

 

 

To set the minutes, snooze time, month, alarm time in 
manual setting modes 

 

 

To stop the alarm  

 

MEMO key 

 

 

To display any of the 3 alarm time settings 

 

 

To stop the alarm  

 

LCD SCREEN 
 
 
 
 
 
 
 
 
 
 
RADIO CONTROLLED TIME: 

The time base for the radio-controlled time is a Cesium Atomic 
Clock operated by the Physikalisch Technische Bundesanstalt 
Braunschweig which has a time deviation of less than one second in 
every one million years. 
The time is coded and transmitted from Mainflingen near Frankfurt 
via frequency signal DCF-77 (77.5 kHz) and has a transmitting 
range of approximately 1,500 km. The alarm clock receives this 
signal and converts it to show the precise time and so when within 
this range the received time is completely accurate. 

 

CHECKING FOR DCF-77 RECEPTION: 

The alarm clock will automatically start scanning for the DCF-77 
frequency signal after the battery is inserted. In normal surroundings 
(for example away from interfering sources such as TV sets), it 
takes between 3-5 minutes to receive the signal. If after 10 minutes 
of inserting the battery into the alarm clock and the DCF-77 signal is 
not received, then check the following list before manually setting 
the time (see 

Manual time setting

 below): 

1.  The distance of the alarm clock should be at least 1.5-2.0 meters 

away from interfering sources such as computer monitors or TV 
sets. 

2.  Avoid placing the alarm clock onto or in the immediate proximity 

of metal doors, window frames or structures. 

3.  Within thick concrete rooms such as basements and tower 

blocks, the DCF-77 signal is naturally weaker. In extreme cases, 
place the alarm clock closer to a window and/or point its front or 
rear towards the general direction of the Frankfurt transmitter 
(avoid placing near metal frames and structures).  

 

Note:  

Users may be located in areas where atmospheric disturbances are 
the direct cause for not receiving the DCF-77 frequency signal. 
During nighttime, atmospheric disturbances are usually less severe 
and reception is possible in most cases. With a single daily 
reception, it is adequate for the alarm clock to keep time deviation to 
below 0.5 seconds in a period of 24 hours. 

 

When reception is successful, the DCF-77 tower icon will start 
flashing on the LCD as a sign that the signal has been found and 
reception is being attempted. Once the signal is “locked”, the DCF-
77 tower icon will stay fixed on the LCD and the received time will 
automatically correct the manually set time. As well as the time, the 
date will also be received by the alarm clock which is displayed 
accordingly in the calendar section of the LCD.  

 

LCD 1- MANUAL TIME SETTING MODE:

 

In some cases after inserting the battery, the alarm clock may not 
be able to receive the DCF-77 signal. In this situation, the time 

should be manually set (before manual setting see 

Checking DCF-

77 Reception

 above). 

1.  Press and hold the MODE/MIN key for 2 seconds, (the time zone 

and snooze time will be displayed), then press the MEMO key. 

2.  Set the time by pressing the AL/HR key to change the hour and 

the MODE/MIN key to enter the minutes (each press or holding 
the keys down will increase the digits by one) 

3.  Once the time is set, either press the MEMO key to change the 

Calendar setting

 or press the SNOOZE key to exit or wait for 

automatic timeout to exit the Manual time setting mode. 

 

Note: 

The alarm clock will still try to receive the signal every hour despite 
it being manually set. When it does receive the signal, it will change 
the manually set time into the received time. During reception 
attempts the DCF tower icon will flash. If reception has been 
unsuccessful, then the DCF tower icon will not appear but reception 
will still be attempted the following hour. 

 

LCD 2 – WEATHER FORECAST AND WEATHER 
TENDANCY INDICATORS 

 

THE WEATHER FORECASTING ICONS: 

There are 3 weather icons on the second section of the LCD which 
can be displayed in any of the following combinations: 

 
 
 
 

             Sunny   Cloudy with sunny intervals   Rainy 

 

For every sudden or significant change in the air pressure, the 
weather icons will update accordingly to represent the change in 
weather. If the icons do not change, then it means either the air 
pressure has not changed or the change has been too slow for the 
Weather Station to register. However, if the icons displayed is a sun 
or raining cloud, there will be no change of icon if the weather gets 
any better (with sunny icon) or worse (with rainy icon) since the 
icons are already at their extremes. 

 

The icons displayed forecasts the weather in terms of getting better 
or worse and not necessarily sunny or rainy as each icon indicates. 
For example, if the current weather is cloudy and the rainy icon is 
displayed, it does not mean that the product is faulty because it is 
not raining. It simply means that the air pressure has dropped and 
the weather is expected to get worse but not necessarily rain. 

 

Note:

 

 

After setting up, readings for weather forecasts should be 
disregarded for the next 12-24 hours. This will allow sufficient time 
for the alarm clock to collect air pressure data at a constant altitude 
and therefore result in a more accurate forecast. 
Common to weather forecasting, absolute accuracy cannot be 
guaranteed. The weather forecasting feature is estimated to have 
an accuracy level of about 75% due to the varying areas the alarm 
clock has been designed for use in. In areas that experience sudden 
changes in weather (for example from sunny to rain), the alarm 
clock will be more accurate compared to use in areas where the 
weather is stagnant most of the time (for example mostly sunny). 

 

If the alarm clock is moved to another location significantly higher or 
lower than its initial standing point (for example from the ground 
floor to the first floor of a house), remove the batteries and re-insert 
them after about 30 seconds. By doing this, the alarm clock will not 
mistake the new location as being a possible change in air-pressure 
when really it is due to the slight change of altitude. Again, disregard 
weather forecasts for the next 12 to 24 hours as this will allow time 
for operation at a constant altitude. 

 

THE WEATHER TENDENCY INDICATOR 

Working together with the weather icons are the weather tendency 
indicators (located on the left and right hand side of the weather 
icons). When the indicator points upwards, it means that the air-
pressure is increasing and the weather is expected to improve, but 
when indicator points downwards, the air-pressure is dropping and 
the weather is expected to become worse. 

 

Taking this into account, one can see how the weather has changed 
and is expected to change. For example, if the indicator is pointing 
downwards together with cloud and sun icons, then the last 
noticeable change in the weather was when it was sunny (the sun 
icon only). Therefore, the next change in the weather will be cloud 
with rain icons since the indicator is pointing downwards. 

 

Note:

 

 

Once the weather tendency indicator has registered a change in air 
pressure, it will remain permanently visualized on the LCD. 

 

LCD-3 TIME ZONE, SNOOZE TIME, DATE ALARM AND 
MEMO ALARM SETTING: 

 

TIME ZONE AND SNOOZE TIME SETTING 

The time zone can be set ±9 hours: 

 
 
 
 

1.  Press and hold the MODE/MIN key for 2 seconds to enter in the 

Time zone and Snooze time setting mode. The time zone digit is 
located on the left side and the snooze time digit is located on 
the right side of the LCD) 

2.  Use the AL/HR key to set the time zone (default time zone “0”). 

The range runs from 0 to +9 and then runs from -9 back to 0 in 
consecutive 1hour interval. 

Note: 

If the Time zone is set to "0“ (0 hour), the calendar will be displayed 
in normal display mode. 
If the Time zone is set to other than "0“, the calendar will not be 
displayed in normal display mode. 
3.  Once the time zone is set, press the MODE/MIN key to set the 

snooze time (on the right side of the LCD).  The snooze time can 
be set between 2 and 15 minutes (default 6 minutes). 

4.  Press the MODE/MIN key again to set the snooze time duration. 

The snooze can be set from 2-15 minutes. 

5.  Press the SNOOZE key or do not touch any buttons for about 8 

seconds. The mode will return to normal display mode. 

 

CALENDAR SETTING 

 
 
 
 
 
 
 
 

The date default of the Weather Forecast Memo Alarm clock is 1.1. 
or MO (Monday). Once the radio-controlled time signals are 
received, the date is automatically updated. However, if the signals 
are not received, you can adjust the date manually. To do this: 
1.  Press and hold the MODE/MIN key for 2 seconds to enter the 

time zone setting mode. The digits start flashing. 

2.  Then press twice the MEMO key to enter into the calendar 

setting mode. 

3.  Press the AL/HR key to set the date display (flashing).  
4.  Press the MODE/MIN key to set the month display (flashing). 
5.  Press the MEMO key again to enter the weekday setting. 
6.  Press the AL/HR key to set the weekday. 
7.  Press the SNOOZE key once more to confirm all settings or do 

not touch any buttons for around 8 seconds. The mode will 
return to normal. 

 

ALARM SETTING  

 

 

 

1.  Press and hold down the AL/HR key for around 2 seconds until 

the digits start flashing in LCD 1. 

2.  Press the AL/HR key again to set the hour and the MODE/MIN 

key to set the minutes. Pressing these keys continuously moves 
the hours and the minutes consecutively by 1. 

Snooze time  

Time zone 

Battery 
compartment 

Function keys 

LCD 
display 

Date and month 
display 

Weekday and date 
display 

Alarm time 

Time display 

Weather 
forecast icon 

Weather 
tendency 
indicator 

Alarm 
icon 

Indoor 
temperature 
display 

Отзывы: