background image

MA10402 - AIR QUALITY MONITOR 

Instructions manual 

 

FEATURES: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Quartz clock  

 

12/24h time display 

 

Indoor and outdoor temperature display in °C/°F  

 

Indoor humidity display in %RH  

 

Air quality sensor for monitoring of indoor air quality  

 

Display of CO

2

 equivalent values and quality indicator 

 

Air quality alarm per LED   

 

Low battery indicator 

 

SETTING UP: 

 

Open the battery cover at the back of the transmitter and open 
the battery cover at the back of the air quality monitor. 

 

Checking the correct polarization (+/- markings), insert 2 x AAA, 
LR03, 1.5V batteries into the battery compartment of the 
outdoor transmitter and insert 2 x C, LR14, 1.5V batteries into 
the battery compartment of the air quality monitor. Replace the 
covers. 

 

When the batteries are inserted, all the segments of the LCD 
will light up briefly. The monitor will receive data signal from the 
outdoor transmitter in a few seconds. 

 

Hold the SET button for 3 seconds to manually enter a time.  
(See 

“Manual Settings”.) 

 

Notes:  

 

The equivalent CO

 in ppm will only be displayed after 30 

minutes. 

 

The air quality sensor will take up to 5 days after inserting 
battery to condition itself for the room it is placed. If the unit is 
placed into another room, there might be a reconditioning time 
of several days as well. 

 

Insert the holder to the bottom of the outdoor transmitter for 
table standing or insert it to the back of the transmitter for wall 
mounting purpose. 

 

Set the air quality monitor in a dry and shaded interior and 
away from sources of interference, such as televisions or metal 
plates. The transmitter should be mounted protected from rain 
and direct sunlight. 
 

REPLACING THE BATTERY IN THE AIR QUALITY MONITOR 

The outdoor transmitter uses 2 x AAA, LR03, 1.5V batteries. 
The air quality monitor uses 2 x C, LR14, 1.5V batteries.  
To replace the batteries, please follow the steps below: 

 

Remove the cover at the back of the air quality monitor or the 
outdoor transmitter. Remove the old batteries and wait 2 
minutes before the next step. 

 

Insert batteries observing the correct polarity (see marking). 

 

Replace compartment cover. 

 
BATTERY CHANGE: 

It is recommended to replace the battery regularly to ensure optimum 
accuracy of the unit. 
 
 
 
 

Add device to MOBILE-ALERTS system 

(MOBILE ALERTS gateway needed, sold separately) 
 
Open the app, dashboard is displayed. Tap "Add new sensor" and 
scan the QR code on the back of the MA10402. Then set a name for 
the sensor. To set a name, select the transmitter and then tap on the 
left area of the pencil icon in the upper right. 

 
Read measurements 

Now you can read the measurements on your mobile phone.

 

 

BUTTON FUNCTIONS: 

The Air Quality Monitor has 4 easy-to-use buttons (at his back) : 

 
 
 
 
 
 
 
 
 
 
 
 

SET button: 

 

Press and hold to enter the manual setting modes:12/24 hour 
time display, manual time setting,  ºC / ºF temperature display,  

 

Exit the manual setting mode 

 

+ button: 

 

Press to change values of all manual settings by 1 unit.  

 

Press and hold to speed up manual setting. 

 

ALERT button: 

 

Press to set the air quality alert to ON / OFF 

 

MIN / MAX button: 

 

Press to view MIN and MAX temperature and humidity values  

 

Press and hold to reset recorded MIN and MAX values 

 

LCD SCREEN 

 

 
 
 
 
 
 
 
 

 
 
 

 
 

MANUAL SETTINGS: 

The following manual settings can be done in the setting mode: 

 

12/24 hour time setting 

 

Time setting 

 

ºC / ºF temperature display setting 

 
Press and hold the SET button for about 3 second to enter the setting 
mode: 

 
12/24 HOUR TIME DISPLAY SETTING

 

 

“12hr” or “24hr” flashes in the LCD. (default 24hr) 

 

Press the 

+

 button 

to select the “12hr” or “24hr” display mode. 

 

Press the 

SET

 button to confirm and continue to the 

manual 

time setting

 

MANUAL TIME SETTING 

To set the clock: 

 

The hour digits start flashing in the time display section. 

 

Press the 

+

 button to adjust the hours and then press the 

SET 

button to go to the minute setting. 

 

The minute will be flashing. Press the 

+

 button to set the 

minutes. 

 

Press the 

SET

 button to confirm and continue to the

 °C/°F 

temperature setting

 

°C/°F TEMPERATURE UNIT SETTING 

The default temperature reading is set to °C (degree Celsius). To 
select °F (degree Fahrenheit): 

 

The “°C” will be flashing, use the 

+

 button to toggle between 

“°C” and “°F”. 

 

Press the 

SET

 button to confirm and

 exit the manual settings

 

MIN/MAX values for temperature and humidity 

Press the 

MIN/MAX

 button for displaying of max./min. of temperature 

and humidity. Press and hold the 

MIN/MAX

 button to reset recorded 

MIN and MAX values. 
 

AIR QUALITY ALERT SETTING 

Press the 

ALERT OFF

 button to activate the air quality alert. The air 

quality alert OFF icon indicates that the alert is set off. No air quality 
OFF icon indicates that the alert is activated. 

 
Note: 

The LED Alert blinks, if the air quality alert is activated and the 

Equivalent CO

2  

ppm

 

is higher than 1500ppm:

 

 

AIR QUALITY INDICATOR 

The air quality indicator is located on the bottom of the LCD. It 
changes from 

“Green” to “Gray”by according to the equivalent CO

2  

ppm value.   
 
 
 
 
 
 
 
 
 
 
 
 
* The air quality value shown, after sensor conditioning, may differ 
 +/- 250 ppm.

 

 
Note: 

A 9-level bar graph is 

used to indicate “Green” to “Gray” air quality 

level in the surrounding environment: 
 

Levels 

Equivalent CO

2

 ppm 

Green (Level 1) 

450 

– 600 ppm 

Level 2 

650 

– 800 ppm 

Level 3 

850 

– 1000 ppm 

Level 4 

1050 

– 1200 ppm 

Level 5 

1250 

– 1500 ppm 

Level 6 

1550 

– 1800 ppm 

Level 7 

1850 

– 2100 ppm 

Level 8 

2150 

– 2400 ppm 

Gray (Level 9) 

≥ 2450 ppm 

 
Troubleshooting 

When no sensor readings are displayed in the app, check if the green 
LED on the gateway is permanently lit. If not, please check if: 

 

The gateway is properly connected to the power plug, the 
router and is turned on. 

 

Restart the station by removing the batteries for a minute and 
reinserting, to restart the device. 

 

Your phone is connected to the internet. 

 

The signal is weakened by thick walls and ceilings. Put the 
device in operation near the gateway and then locate a suitable 
location. 

 

More information and detailed instructions can be found in the app at 
“Info” or a

www.mobile-alerts.eu

 

 
Summary of the Declaration of Conformity:  We hereby declare that 
this device does comply with the requirements of RED Directive 
2014/53/EU. 
The declaration of Conformity can be found at

www.mobile-

alerts.eu/technoline/doc

 

 

SPECIFICATIONS

Recommended temperature range: +5ºC to +40ºC / +41ºF to 104ºF 
 

Temperature measuring range: 

Indoor:  

 

-9.5ºC to +59.5ºC with 0.5ºC resolution /  
14.0ºF to +139.5ºF with 0.5ºF resolution 
(OFL displayed if outside this range. In degree F 
display, OFL will displayed when over 99.9ºF) 

Outdoor:    

-

 

39.9ºC to +59.9ºC with 0.1ºC resolution /  

-39.8ºF to +139.8ºF with 0.2ºF resolution 
(OFL displayed if outside this range. In degree F 
display, OFL will displayed when over 99.9ºF) 
 

Relative humidity measuring range: 

Indoor:   

 

20% to 95% with 1% resolution 

(display “- -“ if 

temperature is OFL, except when the temperature is 
100ºF to 139.8ºF; display “19%” if < 20% and “96%” 
if > 95%) 

 

Equivalent CO

2  

ppm measuring range: 

450ppm to 3950ppm with 50ppm resolution (display OFL > 3950ppm) 

 

Measuring intervals: 

Indoor temperature checking interval: 

every 16 seconds   

Indoor humidity checking interval: 

every 16 seconds 

Air quality level checking interval: 

every 3 minutes   

 

Transmission: 

Transmission range: 100m / 330 feet 
Transmission frequency: 868 MHz 
Maximum transmission power MA10402: 3.8 dBm 
Maximum transmission power TX47-IT: 5.2 dBm 

 
MA10402 dimensions

 (L x W x H):  

142,5 x 117,1 x 41,6 mm 

MA10402 power consumption: 

  

2 x C Baby LR14, 1.5V

 

TX47-IT dimensions

 (L x W x H): 

32 x 87 x 17 mm

 

TX47-IT power consumption: 

  

2 x LR03 Micro AAA, 1.5V 

 
Trouble shooting 

Keep in mind that the outdoor transmitter only has the optimal 
transmission range in open area with no obstructions. Each 
obstruction between the transmitter and the station (roof, walls, floors, 
ceilings, thick trees, etc.) will effectively cut the transmission range in 
half. 

 

Liability disclaimer 

 

The electrical and electronic wastes contain hazardous 
substances. Disposal of electronic waste in wild country and/or 
in unauthorized grounds strongly damages the environment. 

 

Please contact your local or/and regional authorities to retrieve 
the addresses of legal dumping grounds with selective 
collection. 

 

All electronic instruments must from now on be recycled.  User 
shall take an active part in the reuse, recycling and recovery of 
the electrical and electronic waste. 

 

The unrestricted disposal of electronic waste may do harm on 
public health and the quality of environment. 

 

Reading of the

User manual

 is highly recommended for the 

benefit of the user. This product must however not be thrown in 
general rubbish collection points. 

 

The manufacturer and supplier cannot accept any responsibility 
for any incorrect readings and any consequences that occur 
should an inaccurate reading take place. 

 

This product is designed for use in the home only as indication 
of the measured data. 

Function  

buttons 

LCD display 

 

Battery 

compartment 

SET button 

MIN / MAX 
button 

+ button 

ALERT OFF 
button 

Air quality alert 

Off icon  

Low battery 
icon (TX for 
outdoor 
sensor 

– RX for 

air quality 
monitor)

 

Equivalent CO

2  

in ppm / seconds 
display 

Air quality 
 indicator 

Bar graph 

Equivalent CO

2  

ppm (parts per 
million) value* 

Air quality 
 indicator

 

Time 

Outdoor 

temperature in 

ºC/ºF 

Reception 
icon

 

Indoor  
temperature 
& humidity  

MIN / MAX icons 

 

 

 

 

 

 

Отзывы: