Cardio WAVE : Service & maintenance manual - rev. 4.1
Pagina 9.25
9.5.1.1.
Table of configuration parameters
To correctly display the parameter values, you need to load them from the low kit, using
the “Read from low kit” function.
After any changes to the parameter values, you need to save them in the low kit using
the “Write to low kit” function.
Id
(Par.) Units
Name
Description
VISIO
Powered
1
decimal [Rt]
Transmission Ratio
3412
2
[Rvel]
Speed ratio
400
3
mA
[Im]
Minimum braking
500
4
W
[Pmc]
Constant maximum power
200
5
in
cents
[Km2]
Power factor correction (constant torque)
85
6
0.1N
[Ca]
User friction torque
10
7
°C
[Tea]
Maximum temperature on the coil
125
8
User
rpm
[RPMmin]
Minimum user SPM (start cut braking ramp)
35
9
Type/sec [RpmF1]
Flywheel target RPM speed in standby
(and power-on speed for self powered)
250
10
User
rpm
[RpmF2]
Rpm filter threshold
75
11
[Rvel]
Speed ratio (decimal part)
0
12
0.1N
[D_Ca]
User delta friction torque
30
13
-
-
Enable flag for registers at address ≥ 100
-
Содержание WAVE EXCITE+
Страница 1: ...W WA AV VE E E X C I T E REV 4 1...
Страница 2: ......
Страница 4: ......
Страница 10: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina vi Page intentionally left blank...
Страница 32: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 2 20 Page intentionally left blank...
Страница 50: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 3 18 Page intentionally left blank...
Страница 184: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 9 26 Page intentionally left blank...
Страница 186: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 10 2 Page intentionally left blank...
Страница 197: ......