VARIO : Service & maintenance manual- rev. 4.2
Page 6.41
6.15.2.
H
AND
S
ENSOR
HUMAN BODY “CONTINUITY”: it’s well known that for somebody it’s very
difficult, nearly impossible, to measure their HR using the hand sensors. This due to a
lot of possible causes which could fake the “quality” of the contact between the human
skin and the HS plates, as: hands only just washed or particularly dry, acidity of the
skin and/or a particular body fat mass index. For these people it’s suggested to wear
the chest belt transmitter.
HS CORRECT USE: Grasp both the upper and lower plate avoiding clenching them
too hardly. Avoid washing the hands using soaps that can dry the skin too much.
NO
Receiver Board
defective.
Replace.
THE TELEMETRIC HR
SIGNAL IS INCORRECT
(Hand Sensor)
Set the priority on the
Hand Sensor.
Problem solved?
Check the state of
wear of Hand Sensor cable.
Problem solved?
OK
OK
NO
2
OK
NO
YES
Check the Display SW
versione and the grounding of
the Receiver Board.
3
YES
YES
1
NO
Содержание Vario Excite + 500
Страница 1: ...V VA AR RI IO O E X C I T E REV 4 2...
Страница 2: ......
Страница 4: ......
Страница 10: ...VARIO Excite Service maintenance manual rev 4 2 Page vi Page intentionally left blank...
Страница 18: ...VARIO Excite Service maintenance manual rev 4 2 Page 2 6 2 5 2 EUROPEAN AND OVERSEAS PACKING DIMENSIONS...
Страница 58: ...VARIO Excite Service maintenance manual rev 4 2 Page 5 6 Page intentionally left blank...
Страница 170: ...VARIO Excite Service maintenance manual rev 4 2 Page 7 70 Page intentionally left blank...
Страница 206: ...VARIO Excite Service maintenance manual rev 4 2 Page 9 26 Page intentionally left blank...
Страница 208: ...VARIO Excite Service maintenance manual rev 4 2 Page 10 2 Page intentionally left blank...
Страница 219: ......