6.3. THE RESISTANCE IS INCORRECT
The resistance is incorrect if the alternator does not receive the correct excitation signal or if the
power resistor is defective.
THE
RESISTANCE IS
INCORRECT
Is the alternator excitation
voltage correct?
Is the excitation voltage
output by the alternator
interface board correct?
Is the power resistor value
correct?
Replace the power
resistor
Check and/or replace
cable between alternator
and alternator interface
board
YES
NO
YES
NO
NO
YES
1
2
3
Does the alternator interface
board receive the correct
control signal?
Replace the alternator
interface board
YES
NO
4
Replace the alternator
Does the CPU board send
the correct control signal to
the alternator interface
board?
Replace the alternator
interface board
YES
NO
5
Replace the cable
between the CPU board
and the panel connector
Содержание Recline 600 XTPRO
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 1 1...
Страница 2: ......
Страница 4: ......
Страница 8: ...RECLINE 600 XTPRO Service Maintenance Manual rev 1 1 Page iv Page intentionally left blank...
Страница 12: ...RECLINE 600 XTPRO Service Maintenance Manual rev 1 1 Page 2 2 2 5 WIRING DIAGRAM WITH NON CODED RECEIVER...
Страница 26: ...RECLINE 600 XTPRO Service Maintenance Manual rev 1 1 Page 4 2 Page intentionally left blank...
Страница 42: ...RECLINE 600 XTPRO Service Maintenance Manual rev 1 1 Page 6 14 Page intentionally left blank...
Страница 72: ...RECLINE 600 XTPRO Service Maintenance Manual rev 1 1 Page 9 6 Page intentionally left blank...
Страница 84: ...RECLINE 600 XTPRO Service Maintenance Manual rev 1 1 Page 11 8 Page intentionally left blank...
Страница 85: ......