BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 9.4
motor goes beyond the position to be reached; the control drives it back and forth
several times until it is locked in the correct position, causing the relays to sputter.
Enter the value, then press “Enter” to continue or “Clear” to abort.
9.2.5. W
EIGHT STACK MOTOR SELECTION WINDOW
This option allows you to set the width of the selection window, expressed in pulses produced by
the encoder associated with the weight stack motor, corresponding to secure, silent plate selection.
O F F S E T W E I G H T L I F T E D
P U L S E S = 1 0
Indeed, if the user begins the exercise during weight selection, the desired result is for the weight
stack selection system to stop immediately in a position where plate selection is safe and silent.
This value depends on the type of motor used and the mechanics used to make the
selection. This value is factory-set to 10, but it may be necessary to change it due to
changes in the selection system conditions.
Enter the value, then press “Enter” to continue or “Clear” to abort.
9.2.6. D
ISTANCE BETWEEN PLATES
This option allows you to set the distance, expressed in pulses produced by the encoder associated
with the weight stack motor, between plates in the weight stack. Data should be entered beginning
with:
P L A T E 0 - 1 D I S T A N C E
P U L S E S = X X
through:
P L A T E 2 2 - 2 3 D I S T A N C E
P U L S E S = X X
This value depends on the mechanics of the weight stack, in particular the presence of
spacers between plates. When using the machine, these spacers--especially those of the
last plates because of the weight of the entire weight stack--may vary in thickness,
thereby creating problems with selecting the weight stack correctly.
These distances are factory-set as indicated in the table below:
Plates
Distance
0 – 1
24
1 – 2
24
2 – 3
23
3 – 4
24
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......