7.9.11. D
ISASSEMBLING THE WEIGHT STACK COVER FRAME
Figure 7.9.11-1
Follow the steps described in paragraphs 7.9.8.
“Disassembling the plexiglas weight stack
guard”, 7.9.9. “Disassembling the weight stack
pulleys” and 7.9.10. “Disassembling the
encoder”.
1. Disconnect the connector
a
from the solenoid
cable.
2. Remove the spiral cable
b
and its guide
c
from the hook
d
.
Figure 7.9.11-2
3. Cut the clamp
e
.
4. Cut the clamp
f
.
5. Disconnect the patch cord
g
of the solenoid
cable.
6. Unscrew the 6 screws
h
using a 8-gauge
hexagonal T-wrench.
7. Pull the 2 column extensions and the
WEIGHT STACK COVER FRAME upward.
To reassemble the WEIGHT STACK COVER
FRAME, follow the above steps in reverse order.
When the operation is complete, adjust
the cable tension as described in
paragraph 8.4. .
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......