4.2 Standard radio channels 

 

 

BK43-3A 

25KHz 

BK43-3C 

25KHz 

BK43-6B 

12.5KHz 

BK43-9A 

25KHz

 

BK43-1A 

12.5KHz

 

 

CH 1 

433.825 

433.825 

436.00625 

439.700 

441.0250 

 

CH 2 

433.875 

433.875 

436.01875 

439.725 

441.0750 

 

CH 3 

433.925 

433.925 

436.03125 

439.750 

441.1250 

 

CH 4 

433.975 

433.975 

436.04375 

439.775 

441.1750 

 

CH 5 

434.025 

434.025 

436.05625 

439.800 

441.2250 

 

CH 6 

434.075 

434.075 

436.06875 

439.825 

441.2750 

 

CH 7 

434.125 

434.125 

436.08125 

439.850 

441.3250 

 

CH 8 

434.175 

434.175 

436.09375 

439.875 

441.3750 

 

CH 9 

433.825

 123

 

433.825

 123

 

436.00625

 123

 

439.900 

441.4250 

 

CH 10 

433.875

 123

 

433.875

 123

 

436.01875

 123

 

439.925 

441.4750 

 

CH 11 

433.925

 123

 

433.925

 123

 

436.03125

 123

 

439.950 

441.5250 

 

CH 12 

433.975

 123

 

433.975

 123

 

436.04375

 123

 

439.975 

441.5750 

 

CH 13 

434.025

 123

 

434.025

 123

 

436.05625

 123

 

 

441.6250 

 

CH 14 

434.075

 123

 

434.075

 123

 

436.06875

 123

 

 

441.6750 

 

CH 15 

434.125

 123

 

434.125

 123

 

436.08125

 123

 

 

441.7250 

 

CH 16 

434.175

 123

 

434.175

 123

 

436.09375

 123

 

 

441.7750 

 

CH 17 

433.900 

433.900 

436.00625 

 

 

 

CH 18 

433.950 

433.950 

436.01875 

 

 

 

CH 19 

434.100 

434.100 

436.03125 

 

 

 

CH 20 

434.150 

434.150 

436.04375 

 

 

 

CH 21 

434.200 

434.200 

436.05625 

 

 

 

CH 22 

434.400 

439.390 

436.06875 

 

 

 

CH 23 

 

439.410 

436.08125 

 

 

 

CH 24 

 

439.430 

436.09375 

 

 

 

 
 
 

Содержание RDM BK43-1A

Страница 1: ...Technical Manual Page 1 of 17 www technofase com RDM BK43 Valid for versions RDM BK43 1A RDM BK43 3A RDM BK43 3B RDM BK43 6B RDM BK43 9A...

Страница 2: ...Reference Standard 8 3 2 CEPT 70 03 Recommendation 9 3 3 Identification 9 4 Technical data 10 4 1 Models available 10 4 2 Standard radio channels 11 4 3 Communication interfaces 12 4 4 Power supply 12...

Страница 3: ...Technical Manual Page 3 of 17 www technofase com 8 1 Terms of the guarantee 16 9 1 Standard concerning disposal 17 Manufacturer 17...

Страница 4: ...e As the system works by means of radio waves transmission may in certain cases be influenced by the environment and by the method of use The manufacturer is not liable for any damage to persons and o...

Страница 5: ...cific training in local and national electrical standards Several symbols are used in this manual to highlight certain information The purpose of these symbols is to draw the attention of personnel in...

Страница 6: ...evant local and national standards in force Supplementary notes for RADIO interface appliances The products with radio interface have been designed to operate on UHF radio frequencies 433 436MHz that...

Страница 7: ...Considerable immunity to disturbances Compact size IP65 die cast aluminium casing Easily accessible RS232 communication port Up to 16 programmable channels that can be set using the buttons Power sup...

Страница 8: ...00 6 3 Immunity to disturbances EN 50082 2 Conducted emissions EN 60950 Electrical safety EN 301 489 1 EN 301 489 3 Radio appliances EN 300 220 1 EN 300 220 3 ISM Band SRD EN 300 296 2 3 1 Reference S...

Страница 9: ...e it must be used on the time scale for 10 max of an hourly duty cycle corresponding to 6 minutes of use per hour NOTE In view of the construction system the user is responsible for compliance with th...

Страница 10: ...441 025 441 775MHz 500mW ERP 5 1 This model can only be used in Austria and Switzerland after payment of the local licence fee 2 This model can only be used in countries in which this power limit is...

Страница 11: ...375 439 875 441 3750 CH 9 433 825 123 433 825 123 436 00625 123 439 900 441 4250 CH 10 433 875 123 433 875 123 436 01875 123 439 925 441 4750 CH 11 433 925 123 433 925 123 436 03125 123 439 950 441 52...

Страница 12: ...ry low safety voltage supply protected against short circuits Supply voltage 10 15V Maximum absorption in Tx 400 mA Protection against short circuits Polyswitch Type Resettable RXE040 4 5 Connections...

Страница 13: ...a support plate with a 24 mm hole in the centre This plate must then be fixed to a suitable means of support 5 2 Assembly inside an electrical panel For assembly inside an electrical panel a hole 24 m...

Страница 14: ...channels press the CHANNEL button until the number shown on the display starts flashing ACTUAL CHANNEL then press the INCREMENT button to increase the channel number To lower the number continue pres...

Страница 15: ...Technical Manual Page 15 of 17 www technofase com 7 Labelling of the various models 7 1 RDM BK43 3A label 7 2 RDM BK43 3B label 7 3 RDM BK43 6B label 7 4 RDM BK43 9A label...

Страница 16: ...omponents at the time of purchase and the labour necessary to repair them The guarantee is null and void in the event of improper use of the product negligence intentional damage or any problem due to...

Страница 17: ...point at the end of its life Separate waste collection and subsequent recycling processing and the eco friendly disposal of exhausted appliances contribute towards preventing negative effects on the e...

Отзывы: