background image

1

Series switch

Instruction

 manual

Keep the operating instructions in a safe 

place for later use and teaching-in of the 

product.

Содержание Switch Series

Страница 1: ...1 Series switch Instruction manual Keep the operating instructions in a safe place for later use and teaching in of the product ...

Страница 2: ...onnection 16 5 Integration into the Z Wave network Adding Inclusion 17 5 1 SmartStart setup 17 5 2 Manual set up 18 5 3 Removing the device from the network 19 5 4 Resetting the device 19 6 Configuration 20 7 Supported association groups 21 8 Basic command class 23 9 Notification command class 23 10 Supported Z Wave command classes 23 11 Central scene command class 26 12 Firmware update 27 13 Tech...

Страница 3: ... them It will help you to use the product as intended and safely It is intended for anyone installing operating cleaning or disposing of the device Store the instruction manual in a safe place for later use A current version of the instruction manual can be found in the download area for your product on the TechniSat website at www technisat de We hope you enjoy your TechniSat Smart Home product Y...

Страница 4: ...atal consequences WARNING Severe injury possibly with fatal consequences CAUTION Injury Indicates an important instruction which you absolutely should observe in order to avoid defects the device loss or misuse of data or unwanted operation It also describes additional functions of your device Beware of electrical voltage Follow all safety information to prevent an electric shock Do not open the d...

Страница 5: ...ed using insulation material may partially or completely form the additional or reinforced insulation Your device bears the CE symbol and complies with all requisite EU standards Electronic devices batteries must not be disposed of with household waste but must be disposed of properly in accordance with Directive 2012 19 EU of the European Parliament and of the Council dated 04 July 2012 on Old El...

Страница 6: ...g instructions to minimise any safety hazards prevent damage to the device and help protect the environment Please read all the safety instructions carefully and store them for future reference Always follow all the warnings and instructions in this instruction manual and on the rear of the device WARNING This device is only intended for installation Only trained personnel electricians may connect...

Страница 7: ...al conditions Do not expose the device to dripping or splashing water protection class IP20 If water has penetrated the device switch it off and inform the service department Do not expose the device to heat sources which could heat it up more than normal use will In the event of an obvious device defect the production of an odour or smoke significant malfunctions or damage to the housing notify t...

Страница 8: ...ons Foreign bodies e g nails coins etc must not be allowed to fall inside the device Do not touch the connection contacts with metal objects or your fingers This may cause a short circuit Never allow children to use the device unsupervised Modifications to the device are prohibited 1 3 1 Legal notices TechniSat hereby declares that the series switch radio equipment complies with Directive 2014 53 ...

Страница 9: ...al You can find the current version of the manual in PDF format in the download area of the TechniSat home page at www technisat com TechniSat is a registered trademark of TechniSat Digital GmbH TechniPark Julius Saxler Strasse 3 D 54550 Daun Vulkaneifel Germany www technisat de Z Wave and Z Wave Plus are registered trademarks of Silicon Laboratories Names of the companies institutions or brands m...

Страница 10: ...e contact the product dealer For questions and information or if there is a problem with this device please contact our technical hotline Mon Fri 8 00 am 6 00 pm at tel 49 0 3925 9220 1800 Repair orders can also be placed directly online at www technisat de reparatur If the device needs to be sent to us for any reason please only use the following address TechniSat Digital GmbH Service Center Nord...

Страница 11: ...a System 55 series This device can be operated in any Z Wave network and with other Z Wave certified devices from other manufacturers Non battery powered devices within the Z Wave network act as repeaters regardless of manufacturer to increase the range and reliability of the network This device is a secured Z Wave Plus product that can communicate with other secured Z Wave Plus products via encry...

Страница 12: ...ions Front using Busch Jaeger as an example T3 T4 LED T1 T2 LED Status LED T1 Upper push button position left T2 Lower push button position left T3 Upper push button position right T4 Lower push button position right ...

Страница 13: ...13 Rear L Phase L1 Switched output to consumer 1 T1 T2 L2 Switched output to consumer 2 T3 T4 N Neutral ...

Страница 14: ...14 4 Connection diagram Connection example N L ...

Страница 15: ...15 4 1 Installation Flush mounted box DIN 49073 1 Frame TechniSat Series switch Balancing frame Rocker switch ...

Страница 16: ...h is designed for cables of 1 5 mm fixed or 1 mm flexible with clamping sleeve The conductor must be stripped by 10 mm The conductor can be connected and disconnected again by pressing the push button with a suitable tool e g a slotted screwdriver 2 5 x 0 4 mm ...

Страница 17: ...nd smartphone camera After scanning it may take up to 10 minutes for your new device to be added to your Z Wave network 1 The Z Wave SmartStart QR code can be found on the back of the TechniSat series switch on the front of this manual or on the device box 2 Activate the SmartStart function in your primary Z Wave controller and follow the operating steps to add a device WARNING Only trained person...

Страница 18: ...0 minutes for the TechniSat series switch to be added to your Z Wave network 5 2 Manual set up WARNING Only trained personnel electricians may connect devices without plugs Risk of electric shock 1 Install the TechniSat series switch in its intended position WARNING The device may only be installed when disconnected from the mains Switch off at the fuse and secure it against being switched on acci...

Страница 19: ...controller to Exclusions mode removing and follow the operating steps 2 Press and hold the upper push button position T1 for at least 10 seconds 3 The LED lights up red while the unlearning process is running 4 The LED lights up green after the device has been successfully removed from the Z Wave network 5 4 Resetting the device Only use the reset in the event that a primary Z Wave controller is m...

Страница 20: ... Z Wave controller Parameter Description Size bytes Value Default 1 Activates Deactivates central scene notification Press 2 to 5 times 1 0 Deactivates 1 Activates 1 2 Current power consumption message interval 2 0 Deactivates unrequested messages 3 8640 30 seconds 1 day 3 30 s 3 Current energy consumption message interval 2 0 Deactivates unrequested messages 10 30240 10 minutes 3 weeks 60 1 hour ...

Страница 21: ... output off 1 T1 T4 switch output on or off respectively 0 7 Supported association groups Main device ID Name Maximum group members CC commands 1 Lifeline 1 Device reset locally notification Central scene notification Meter report Switch binary report Notification report 2 Switch State 1 10 Basic set 3 Switch State 2 10 Basic set ...

Страница 22: ...mands 1 Lifeline 0 Meter report Switch binary report Notification report 2 Switch State 1 10 Basic set Connection 2 ID Name Maximum group members CC commands 1 Lifeline 0 Meter report Switch binary report Notification report 2 Switch State 2 10 Basic set ...

Страница 23: ...switched off a Basic_Set 0 x 00 command is sent to members of association group 2 9 Notification command class Notification Event Description Power management 0 x 08 Inactive 0 x 00 No event detected event cancelled Overload detected 0 x 08 The maximum permissible load on L1 L2 was exceeded 10 Supported Z Wave command classes Main device Command class Version Required Z Wave safety levels Associat...

Страница 24: ...ed Device reset locally 1 highest permitted Firmware update meta data 4 highest permitted Manufacturer specific 2 highest permitted Meter 4 highest permitted Multi channel 4 highest permitted Multi channel association 3 highest permitted Notification 8 highest permitted Power level 1 highest permitted Security 0 1 none Security 2 1 none Supervision 1 none Transport service 2 none ...

Страница 25: ...ssociation 2 highest permitted Association group information 1 highest permitted Basic 2 highest permitted Binary switch 1 highest permitted Meter 4 highest permitted Multi channel association 3 highest permitted Notification 8 highest permitted Security 0 1 none Security 2 1 none Supervision 1 none Z Wave Plus info 2 none ...

Страница 26: ...d multiple times When the respective push button position is pressed multiple times the following trigger notifications are sent Push button position T1 T2 T2 T4 triggered scene number 1 2 3 4 The following push button attributes are used for all scene numbers in trigger notification Push button position T1 T2 T3 T4 pressed Z Wave push button attribute twice Push button pressed twice three times P...

Страница 27: ... controller 2 Perform a firmware version query for the TechniSat series switch on your primary Z Wave controller 3 The LED on the TechniSat series switch lights up red for about 10 seconds once the firmware version query has been received 4 Press T1 T2 T3 or T4 while the LED is lit red to confirm the update request The LED now lights up green for about 10 seconds 5 While the LED is lit green you c...

Страница 28: ...M1 series Busch Jaeger Duro 2000 series Gira System 55 series power supply 230 V AC 10 Frequency 50 Hz 10 Nominal load current of outputs 5 A single output 5 A both outputs together Output performance Apparent power 1 150 W 1 150 VA Power consumption with no load 0 4 W Switch element µ relay with contact opening width 3 mm Operating height 2 000 m above sea level IEC protection class II ...

Страница 29: ...overload detected Green 5 seconds device successfully logged in Z Wave frequency Transmission capacity 868 42 MHz 4 dBm Ambient conditions In operation Temperature 5 C 35 C Humidity 10 75 RH Ambient conditions Storage transport Temperature 20 C 60 C Humidity 5 90 RH non condensing Dimensions W x H x D 70 mm x 70 mm x 45 mm Depending on the model see label on page 1 ...

Страница 30: ...30 ...

Страница 31: ...31 ...

Страница 32: ...32 11032021ORV9 2238031871200 ...

Отзывы: