Techniks EEPM Скачать руководство пользователя страница 1

www.techniksusa.com

EEPM MAGNETIC CHUCKS

OPERATIONS MANUAL

COMPLETE INSTALLATION AND TROUBLESHOOTING GUIDE

Techniks Inc. 9930 E. 56th St.  Indianapolis, IN 46236  |  800.597.3921  |  www.techniksusa.com  |  info@techniksusa.com

Techniks Inc. is a proud member of Techniks Tool Group. 

 

Connect with  TTG 

Содержание EEPM

Страница 1: ...S OPERATIONS MANUAL COMPLETE INSTALLATION AND TROUBLESHOOTING GUIDE Techniks Inc 9930 E 56th St Indianapolis IN 46236 800 597 3921 www techniksusa com info techniksusa com Techniks Inc is a proud member of Techniks Tool Group Connectwith TTG ...

Страница 2: ... magnetic chuck and the workpiece Your results will vary depending upon the size shape thickness and material type you are holding ELECTRICAL NOTES Electricity is NOT required to maintain magnetic holding power Electricity is used only to reverse the polarity of the alnico magnets When in a magnetized state holding power is secure until demagnetized The chuck will NOT lose holding power in the eve...

Страница 3: ...verify the following items were shipped with your order 1 EEPM magnetic chuck 1 chuck controller with attached power supply cable for the chuck 1 auxiliary hand held remote 1 touchscreen HMI remote control 1 set of 4 toe clamps and this Operations Manual Reminder Review the packing list and confirm that all items listed arrived intact and undamged In case of damaged of missing items please contact...

Страница 4: ...he controller body and in good condition 1 2 3 4 5 6 8 7 9 10 11 POWER SUPPLY CHECK PROCEDURE The EEPM chuck and controller must have the correct power supply to operate safely Have a certified electrician test and verify that your power supply meets the power requirements listed below Write the actual readings in the spaces below and fix any problems before attempting to install and operate your ...

Страница 5: ...A CNC MACHINE CONTROL The EEPM magnetic chuck controller can interface with most CNC controls via the 9 pin connection on the back of the controller allowing the magnetic chuck to be operated from the CNC control panel The magnetic status of the EEPM chuck demagnetized or magnetized is indicated with a set of dry contacts connected to pins 1 2 3 of the CNC control connector When the contacts close...

Страница 6: ...ous object screwdriver you should feel a magnetic attraction ADJUSTING THE MAGNETIC HOLDING POWER 1 Adjust the power level as needed using the or keys Magnetize the chuck and verify that it is magnetized 3 Perform the touch test to verify that the magnetic field is no longer strong at the surface of the workpiece POWERING DOWN THE CONTROLLER AND CHUCK 1 Demagnetize the chuck and verify it is demag...

Страница 7: ...ellow lights stay lit and the green light and number 8 flash this indicates an SCR failure YELLOW LIGHT FLASHES FOR 15 SECONDS AND RED LIGHT REMAINS ON During the magnetization process if the red light remains on and the yellow light flashes for 15 seconds this indicates the chuck cable is disconnected from the chuck YELLOW LIGHT FLASHES FOR 15 SECONDS AND THEN GREEN LIGHT REMAINS ON FLASHES Durin...

Страница 8: ...ETIZING THE CHUCK 1 Touch green MAG button 2 Confirmation prompt will appear touch YES 3 Watch for green MAG LAMP light to activate ADJUSTING HOLDING POWER 1 Touch LEVEL setting 2 Power level pad will appear touch desired level 3 Watch for green MAG LAMP light to activate MULTI CHUCK CONTROL SETUP 1 Touch System Setup Enter Chuck Number Setting 2 Touch On to activate your chucks 3 Touch Off to de ...

Страница 9: ...touch confirm button 4 Re start the power if no warning message is displayed the situation is normal LOW VOLTAGE 1 A low voltage is displayed if the voltage drops below 186VAC 2 Check whether the power voltage is within the acceptable voltage range Confirm the voltage improved then touch disable button 3 Re start the power if no warning is displayed the situation is normal CHUCK CABLE DISCONNECTED...

Страница 10: ...re workstops to prevent the part from moving during machining For best results we recommend using workstops whenever possible 5 Adjust the power level as needed using the or keys We recommend using power level 8 for standard operation Magnetize the chuck and verify that it is magnetize 6 Perform a touch test to verify that the magnetic field is no longer strong at the surface of the workpiece If a...

Страница 11: ... is not possible properly disposed of according to local municipal regulations 3 This equipment contains polluting oils that must be disposed of at authorized waste disposal sites There are no user serviceable parts inside the chuck Chuck maintenance is limited the surface finish of the chuck face and verifying that the electrical connection is clean and uncontaminated by chips or liquid Proper ma...

Страница 12: ...tion of this manual b Verify that the power setting on the chuck controller is set to the maximum value 8 The power setting must be changed when the chuck is in a demagnetized state c Verify that both the blue and green buttons on the chuck controller or hand held remote unit are pressed at the same time for a period of one full second Do not hold the buttons down for more than 2 seconds d Verify ...

Отзывы: