Gas Conversion (ULPG to NG)
If the required gas conversion kit is not supplied with your
appliance, contact Technika. Gas Conversion shall only be
undertaken by authorised persons.
The ULPG to NG conversion kit contains...
-
Converting to a different gas type
When converting from ULPG to Natural Gas ensure that the ULPG
test point is removed and replaced with the AGA Approved NG
Regulator supplied in this kit. The test point pressure must be
adjusted to 1.00kPa with the largest burner operating on maximum
flame.
Changing the jets
1. Remove pan supports, burner heads and caps.
2. Use a size 7 socket wrench to unscrew and
remove the jets, replacing them with those
supplied in this kit. Ensure you use the correct jet
for the corresponding burner.
3. Reassemble the burner heads, caps and pan
supports.
4. Fit the Gas type label supplied with this kit next to
the gas connection point and remove the existing
label.
Setting the minimum level
1. Light one of the burners and turn the tap to
minimum flame.
2. Remove the corresponding control knob.
3. Use a thin blade screwdriver to turn the by-pass
screw located in the brass shaft as shown right.
Turn the by-pass screw fully clockwise then turn it
anti-clockwise 1/4 turn for the 4kW Wok and 1/8
turn for the 5kW Wok and all other burners. The
result should be a small, stable flame which is
uniform around the entire burner ring. If not, turn
the by-pass screw anti-clockwise until satisfied
with the flame.
4. Check that the burner does not go out when the
tap is turned quickly from the maximum to the
minimum position.
5. Repeat for each burner.
NG Regulator
- NG
- Auxiliary Jet Ø090mm
- Semi-Rapid Jet Ø1.18mm
- Rapid Jet Ø1.55mm
- 4kW Wok Jet Ø1.80mm
- 5kw Wok Jet 1.80mm, 0.80mm
Gas Type label