file:///C|/Documents%20and%20Settings/Administrator/Plocha/SL-EH570/s0603000000.htm
6.3 Error code based on troubleshooting
TOP
PREVIOUS
NEXT
●
This unit is satisfactory if the error code is
E00
and
E02
.
●
Before testing, check that the test disc is free of scratches and optical pickup is clean.
FL error
code/display
Symptom
Probable
cause
Signal to check
Normal voltage and waveform values
Signal
name
Location
PLAY
STOP
E01
Focus and
tracking
offset
adjustments
not
completed
in the
specified
time
period.
Clocks X1
IN and X2
OUT, power
supply VDD
and
reset/RST,
all on IC702.
MDATA,
MCLK,
MLD and
SENSE
signals
to/from
mechanism
controller.
MDATA
IC702-8
pin
0.3 V
0 V
MCLK
IC702-7
pin
2.9 V
MLD
IC702-9
pin
2.9 V
/RST
IC702-
18 pin
2.9 V
2.9 V
X1 IN
IC702-
58 pin
X2 OUT
IC702-
59 pin
E03, E05,
E07, E09,
E0B, E0D,
E0F
Disc play
unstable.
Scratches or
contaminants
on disc
surface.
Focus and
Tracking
servo circuit
(check
waveforms,
voltages and
part values.)
Spindle
driver
circuit.
Optical
pickup.
FE
IC702-
32 pin
1.7 V